MCP
JC

J. Corbin

6 papers in the library

Papers

6
The Cryogenic System of DMRadio-50L
V. AnkelC. BartramJ. BeginC. BellS. ChaudhuriH. -M. ChoJ. CorbinW. CraddockS. CuadraA. DrosterJ. EcheversE. Engelhardt  +27
The DMRadio-50L experiment searches for axion dark matter with a lumped-element LC resonator and toroidal magnet. This paper presents the custom hybrid cryogenic system that combines a horizontal dilution refrigerator with a large vertical payload cryostat. It cools a 200 kg detector assembly to 50 mK with sufficient cooling power at multiple temperature stages, enabling the experiment in a standard laboratory environment.
arXivarXiv · · July 7, 2026
0
1
DMRadio-Core: A new approach for GUT-scale axion searches
V. AnkelC. BartramJ. BeginC. BellS. ChaudhuriH. -M. ChoJ. CorbinW. CraddockS. CuadraA. DrosterJ. EcheversE. Engelhardt  +24
DMRadio-Core proposes a new experimental geometry for searching GUT-scale QCD axions in the neV/$c^2$ mass range. Instead of placing the LC resonator inside the high-field magnet bore, the design uses a narrow-bore segmented solenoid with resonators outside the high-field region, optimizing signal collection. This substantially reduces required stored magnetic energy while preserving sensitivity, enabling a near-term experiment at 30–200 MHz (120–830 neV/$c^2$) and a staged path to a GUT-scale search at 100 kHz–30 MHz (0.4–120 neV/$c^2$).
arXivarXiv · · April 17, 2026
0
3
Noise limits for dc SQUID readout of high-QQ resonators below 300 MHz
V. AnkelC. BartramJ. BeginC. BellL. BrouwerS. ChaudhuriJohn ClarkeH.-M. ChoJ. CorbinW. CraddockS. CuadraA. Droster  +29
This paper establishes the noise limits for dc SQUID readout of cryogenic high-$Q$ resonators below 300 MHz, using first-stage SQUIDs whose performance follows Tesche-Clarke theory. The analysis includes imprecision, backaction, and their correlations, as well as noise from second-stage SQUIDs, wiring, and preamplifiers, with results referred to the standard quantum limit. Optimizations for on-resonance and off-resonance measurements are provided. This work directly supports the DMRadio-m$^3$ axion search and other low-frequency axion experiments.
arXivarXiv · · April 29, 2025
0
6
Electromagnetic modeling and science reach of DMRadio-m3^3
DMRadio CollaborationA. AlShirawiV. AnkelC. BartramJ. BeginC. BellJ. N. BenabouL. BrouwerS. ChaudhuriH. -M. ChoJ. CorbinW. Craddock  +36
DMRadio-m$^3$ targets QCD axion dark matter in the 10–200 MHz range. It uses a solenoidal dc magnetic field to convert axions into an ac electromagnetic signal in a coaxial pickup, detected by dc SQUIDs. This work presents the electromagnetic modeling of the response from the lumped-element limit up to a regime where the axion Compton wavelength is only twice the detector size. The modeling shows that the primary DFSZ axion sensitivity goal across 30–200 MHz can be achieved with a $3\sigma$ live scan time of 2.9 years.
arXivarXiv · · February 27, 2023
0
Projected Sensitivity of DMRadio-m3^3: A Search for the QCD Axion Below 1 μ1\,μeV
DMRadio CollaborationL. BrouwerS. ChaudhuriH.-M. ChoJ. CorbinW. CraddockC. S. DawsonA. DrosterJ. W. FosterJ. T. FryP. W. GrahamR. Henning  +22
DMRadio-m$^3$ is a next-generation experiment designed to search for QCD axion dark matter below $1\,\mu$eV. It uses a $>4$ T static magnetic field, a coaxial inductive pickup, a tunable LC resonator, and a DC-SQUID readout to detect the axion's coupling to photons via modified Maxwell's equations. The primary science goal achieves DFSZ sensitivity above $m_a c^2\approx 120$ neV (30 MHz), with a secondary goal probing KSVZ axions down to $m_a c^2\approx40$ neV (10 MHz).
arXivarXiv · · April 28, 2022
0
0
Introducing DMRadio-GUT, a search for GUT-scale QCD axions
L. BrouwerS. ChaudhuriH.-M. ChoJ. CorbinC. S. DawsonA. DrosterJ. W. FosterJ. T. FryP. W. GrahamR. HenningK. D. IrwinF. Kadribasic  +20
DMRadio-GUT is a proposed experiment to search for QCD axion dark matter in the highly motivated mass range 0.4–120 neV, corresponding to a GUT-scale axion. The coupling of the QCD axion to photons scales linearly with mass, making this region especially difficult to probe. The paper presents the design requirements needed to conduct a definitive search in this parameter space and reviews the necessary technological advances.
arXivarXiv · · March 21, 2022
0
11
Frequent collaborators
S. Chaudhuri (6)
A. Droster (6)
J. T. Fry (6)
K. D. Irwin (6)
A. Keller (6)
R. Kolevatov (6)
N. M. Rapidis (6)
C. P. Salemi (6)
M. Simanovskaia (6)
J. Singh (6)
E. C. van Assendelft (6)
K. van Bibber (6)