Ultra-low phase noise all-optical microwave generation setup based on commercial devices
A. DidierJ. MilloS. GropB. DuboisE. BiglerE. RubiolaC. LacroûteY. Kersalé
This paper reports an all-optical microwave generation setup that achieves ultra-low phase noise using only commercial devices. A commercial femtosecond laser is locked to a laser stabilized to a commercial ULE Fabry-Perot cavity. The extracted 10 GHz signal has a single-sideband phase noise of $\mathcal{L}(f) = -104 \ \mathrm{dBc}/\mathrm{Hz}$ at 1 Hz offset, matching the best laboratory results. This design makes such signals accessible beyond metrology labs.
arXivarXiv · · March 20, 2015
0
Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
J. J. McFerranD. V. MagalhaesC. MandacheJ. MilloW. ZhangY. Le CoqG. SantarelliS. Bize
By trapping Hg atoms in an optical lattice in the Lamb-Dicke regime, the authors obtain a sub-15 Hz spectral line at 265.6 nm and lock an ultrastable laser to this clock transition. The locked laser achieves a fractional frequency instability of $5.4\times 10^{-15}/\sqrt{\tau}$ for $\tau\leq 400$ s. The probe light is derived from a 1062.6 nm fiber laser stabilized to a cavity with a mean drift of $-6.0\times 10^{-17}$ s$^{-1}$ over five months.
arXivarXiv · · May 18, 2012
0
An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
S.T. DawkinsR. ChicireanuM. PetersenJ. MilloD.V. MagalhãesC. MandacheY. Le CoqS. Bize
The paper presents an ultra-stable deep-UV interrogation source for a mercury optical lattice clock. A Fabry-Pérot cavity with fused-silica mirrors (low thermal noise) stabilizes a 1062.6 nm fiber laser. The signal is referenced to primary frequency standards via an optical frequency comb, achieving fractional stability at the 1E-15 level. After two frequency-doubling stages, several milliwatts at 265.6 nm are obtained for clock interrogation.
arXivarXiv · · March 22, 2010
0
Ultra-Low Noise Microwave Extraction from Fiber-Based Optical Frequency Comb
J. MilloR. BoudotM. LoursP. Y. BourgeoisA. N. LuitenY. Le CoqY. KersaleG. Santarelli
This letter reports an all-optical fiber approach for generating ultra-low noise microwave signals. By phase-locking two erbium fiber mode-locked lasers to a common ultra-stable laser source, an 11.55 GHz signal is produced with an unprecedented relative phase noise of -111 dBc/Hz at 1 Hz offset from the carrier. The residual frequency instability of the derived microwaves is below 2.3×10^(-16) at 1 second and about 4×10^(-19) at 6.5×10^4 seconds, measured in a 5 Hz bandwidth over three days of continuous operation.
arXivarXiv · · June 25, 2009
0
Ultrastable lasers based on vibration insensitive cavities
J. MilloD. V. MagalhaesC. MandacheY. Le CoqE. M. L. EnglishP. G. WestergaardJ. LodewyckS. BizeP. LemondeG. Santarelli
The paper presents two ultrastable lasers built from vibration-insensitive cavities, one with vertical and one with horizontal optical axis. Using fused silica mirror substrates reduces the thermal noise limit, improving frequency stability. Vibration sensitivity in each spatial direction is at or below $1.5 \times 10^{-11}$ per $\text{m} \cdot \text{s}^{-2}$, and the design eliminates fine-tuning of support points. One laser achieves a relative frequency stability better than $5.6 \times 10^{-16}$ at 1 second, the best reported for this cavity length.
arXivarXiv · · January 29, 2009
0
312
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
J. MilloM. AbgrallM. LoursE.M.L. EnglishH. JiangJ. GuenaA. ClaironS. BizeY. Le CoqG. SantarelliM.E. Tobar
The authors generate a low-noise microwave reference by locking a fiber-based femtosecond laser to an ultra-stable optical cavity. The system achieves stability of about $3\times10^{-15}$ from 1 s to 10 s, comparable to a cryogenic sapphire oscillator (CSO) and a Ti:Sapphire comb. Applied to Ramsey spectroscopy in a cesium fountain clock, it yields a stability of $3.5\times10^{-14}\tau^{-1/2}$. The continuously operated fiber setup thus shows potential to replace the CSO in high-stability atomic clocks.
arXivarXiv · · January 23, 2009
0
Frequent collaborators
Y. Le Coq (5)
G. Santarelli (4)
S. Bize (4)
C. Mandache (3)
D. V. Magalhaes (2)
M. Lours (2)
A. Didier (1)
S. Grop (1)
B. Dubois (1)
E. Bigler (1)
E. Rubiola (1)