MCP
JP

J. Pena

10 papers in the library

Papers

10
Colors of Irregular Satellites of Saturn with DECam
J. PeñaC. Fuentes
This paper reports new $g-r$ and $r-i$ colors for 21 Saturn Irregular Satellites (4 unreported before), the largest single survey. Colors were measured by stacking observations to boost signal without trailing, using a novel algorithm that detects faint sources under significant background noise and crowded fields. The results show consistency with other irregular satellite populations and reinforce that the lack of ultra-red objects among irregular satellites distinguishes them from trans-Neptunian objects, supporting their posited origin.
arXivarXiv · · April 18, 2022
0
Osteostatin potentiates the bioactivity of mesoporous glass scaffolds containing Zn2+ ions in human mesenchymal stem cell cultures
C. HerasS. Sanchez-SalcedoD. LozanoJ. PeñaP. EsbritM. Vallet-RegiA.J. Salinas
Hierarchical meso-macroporous 3D scaffolds made of mesoporous bioactive glasses (MBGs) were designed with the peptide osteostatin and Zn²⁺ ions. In human mesenchymal stem cell (hMSC) cultures, zinc promoted cell colonization throughout the scaffolds. Critically, only the combined presence of Zn²⁺ and osteostatin—neither alone—induced osteoblast differentiation markers RUNX2 and ALP after 7 days without osteogenic medium, pointing to a synergistic strategy for bone regeneration.
arXivarXiv · · March 23, 2021
0
Asteroids' Size Distribution and Colors from HiTS
J. PeñaC. FuentesF. FörsterJ. Martínez-PalomeraG. Cabrera-VivesJ.C. MaureiraP. HuijseP.A. EstévezL. GalbanyS. González-GaitánTh. de Jaeger
From the 2015 HiTS campaign, 5740 solar system objects (mostly Main Belt asteroids) were detected. The size distribution of Main Belt objects follows a power law with slope $\sim0.9$, steeper than that found in 2014 ($\sim0.68$ at bright end, $\sim0.34$ at faint end) and previous surveys, likely because 2015 surveyed farther from the ecliptic. No $g'-r'$ color-size correlation was found for $14<H_{g'}<18$ ($1<D<10$ km) asteroids.
arXivarXiv · · March 11, 2020
0
21
Asteroids in the High cadence Transient Survey
J. PeñaC. FuentesF. FörsterJ.C. MaureiraJ. San MartínJ. LittínP. HuijseG. Cabrera-VivesP.A. EstévezL. GalbanyS. González-GaitánJ. Martínez  +2
The authors repurpose the High cadence Transient Survey (HiTS) 2014 data, originally for static variable sources, to detect Solar System objects. They use a custom algorithm linking trajectories under Keplerian motion to derive asteroid orbital parameters. For known asteroids, orbital fits yield typical errors of 0.07 AU in semi-major axis, 0.07 in eccentricity, and 0.5° in inclination. They extract 7,700 orbits, including 19 near-Earth objects, 6,687 asteroids, 14 Centaurs, and 15 trans-Neptunian objects, demonstrating the value of supernova surveys for Solar System science.
arXivarXiv · · June 8, 2018
0
9
The DAMIC dark matter experiment
A. Aguilar-ArevaloD. Amidei…J. Pena
The DAMIC experiment uses scientific-grade CCDs to search for dark matter. Its low electronic noise achieves an energy threshold of a few tens of eV, enabling detection of silicon recoils from low-mass WIMPs. The CCD's high spatial resolution and energy response provide effective background identification. This technology uniquely targets dark matter particles below 10 GeV/c$^2$, motivating the construction of DAMIC100, a 100 g silicon detector at SNOLAB.
arXivarXiv · · October 7, 2015
0
28
Status of the DAMIC direct dark matter search experiment
DAMIC CollaborationA. Aguilar-Arevalo…J. Pena
The DAMIC experiment uses fully depleted, high-resistivity CCDs with a ~50 eV$_{ee}$ threshold to search for dark matter, achieving unrivaled sensitivity to WIMPs below 6 GeV/$c^2$ by suppressing radioactive backgrounds. A 100 g detector (DAMIC100) is being installed at SNOLAB. This contribution reports installation progress, near-threshold calibration, a preliminary 2014 result, and expected physics output after one year.
arXivarXiv · · September 30, 2015
0
1
Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
A. Aguilar-ArevaloD. Amidei…J. Pena
The DAMIC collaboration measures radioactive contamination in its high-resistivity silicon CCDs used for dark matter searches. By exploiting the CCDs' spatial resolution, new methods identify alpha and beta particles. Alpha spectroscopy yields upper limits on $^{238}$U and $^{232}$Th decay rates of 5 and 15 kg$^{-1}$ d$^{-1}$ (95% CL). A search for spatially correlated beta-decay sequences finds a $^{32}$Si decay rate of $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI) and an upper limit on $^{210}$Pb of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL). These contamination levels are low enough for the upcoming 100 g DAMIC detector.
arXivarXiv · · June 8, 2015
0
69
Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance
J. PardoL. FrancoF. GomezA. IglesiasA. PazosJ. PenaR. LobatoJ. MosqueraM. PombarJ. Sendon
A 128-pixel liquid isooctane (C$_{8}$H$_{18}$) filled linear array, with each pixel measuring 1.7 mm $\times$ 1.7 mm and a 0.5 mm gap, is developed for radiotherapy QA. Its small pixel size suits high-gradient IMRT and radiosurgery profiles. Tests show dose-rate dependence below 2.5% up to 5 Gy/min, energy dependence below 2.1% up to 20 cm depth in solid water, and signal reproducibility within 2% over three months. Output factors and penumbras for rectangular fields, as well as IMRT and virtual wedge profiles, agree well with air ionization chamber and radiographic film measurements.
arXivarXiv · · December 1, 2004
0
36
Free ion yield observed in liquid isooctane irradiated by gamma rays. Comparison with the Onsager theory
J. PardoF. GomezA. IglesiasR. LobatoJ. MosqueraA. PazosJ. PenaM. PombarA. RodriguezJ. Sendon
This paper tests the Onsager theory of initial recombination against free-ion-yield data from gamma-irradiated liquid isooctane. Using three electron thermalization-distance distributions (delta, Gaussian, exponential), the authors find that the Onsager model predicts a linear dependence of yield on applied electric field for $E<1.2$ MV/m, matching experiment excellently. At higher fields, a power-series solution derived from the same theory agrees with measurements, confirming the theory's validity across the studied range.
arXivarXiv · · August 1, 2003
0
A two dimensional position sensitive gas chamber with scanned charge transfer readout
F. GomezA. IglesiasR. LobatoJ. MosqueraJ. PardoJ. PenaA. PazosM. PombarA. Rodriguez
A two-dimensional position-sensitive parallel-plate gas ionization chamber is constructed using a scanned charge transfer readout method. Perpendicularly oriented gate strips to the collector strips enable efficient charge transfer with a low gating voltage, reducing the number of readout channels. The prototype covers 8×8 cm² with a 1.27×1.27 mm² pixel size, and smaller pixels or larger areas are feasible. The detector is suitable for X-ray or continuous beam intensity profile monitoring.
arXivarXiv · · March 20, 2003
0
Frequent collaborators
C. Fuentes (3)
A. Aguilar-Arevalo (3)
D. Amidei (3)
X. Bertou (3)
M. Butner (3)
G. Cancelo (3)
A. Castañeda Vázquez (3)
S. Dixon (3)
J. Estrada (3)
G. Fernandez Moroni (3)
F. Izraelevitch (3)
A. Kavner (3)