MCP
JR

J. Renner

66 papers in the library

Papers

30
Evaluation of tracking plane pitch and xenon-helium gas mixtures for the NEXT experiment
NEXT CollaborationM. Pérez ManeiroM. CidJ. D. VillamilS. TorelliN. López-MarchJ. RennerS. R. SoletiJ. A. Hernando MorataJ. J. Gómez-CadenasH. AlmazánV. Álvarez  +95
Using Monte Carlo simulations in the NEXT-100 geometry, with a sparse convolutional neural network separating signal from background, this study identifies optimal configurations for SiPM-based tracking planes in the NEXT neutrinoless double-beta decay program. Topological rejection power roughly doubles at 5 bar versus the 13.5 bar baseline; at 13.5 bar, finer pitch (15 mm to 5 mm) cuts accepted background by about 1.4 for fixed signal efficiency, and helium addition cuts it by up to 1.5. The authors highlight pure Xe at 15 mm and a Xe-He mixture at 10 mm as practical 13.5 bar options.
arXivarXiv · · November 18, 2026
0
Detection of scintillation light in noble gases with wavelength-shifting optical fibers
S. R. SoletiS. Torelli…J. Renner
The paper investigates wavelength-shifting (WLS) fibers coated with tetraphenyl butadiene (TPB) for detecting vacuum-ultraviolet scintillation light in gaseous xenon and argon at pressures up to 8.5 bar, targeting future high-pressure xenon time-projection chambers. In two detector configurations (SiPM and PMT readout), the central contribution is a measured light collection efficiency (LCE) of $1.18\%$ (SiPM, Xe) and $0.45\%$ (PMT, Xe), with the SiPM result representing an upper limit for realistic large-scale TPCs where additional photon losses are expected.
arXivarXiv · · July 6, 2026
0
0
Radon-induced backgrounds in the NEXT-100 experiment
NEXT CollaborationC. Cortes-Parra…J. Renner
The NEXT-100 experiment measured radon-induced backgrounds for its search for neutrinoless double-beta decay. The internal $^{222}$Rn activity was (0.95±0.04(stat)±0.09(sys)) Bq/m$^3$. The resulting background index in the region of interest is $(7.3±1.5(stat)±0.8(sys))\times10^{-4}$ counts/(keV·kg·yr) for fully contained events. Applying a topological selection that requires a single double-electron-like track reduces this index to $\sim4\times10^{-5}$ counts/(keV·kg·yr), one order of magnitude below the total radiogenic background expectation.
arXivarXiv · · April 21, 2026
0
0
Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector
NEXT CollaborationJ. RennerJ. D. VillamilN. López-MarchK. MistryP. NovellaA. SimónV. ÁlvarezJ. M. Benlloch-RodríguezM. CidC. Cortes-ParraR. Esteve  +102
Using the NEXT-DEMO++ high-pressure xenon gas time projection chamber, a prototype for NEXT-100, the electroluminescence (EL) yield was measured as a function of reduced electric field ($E/p$) across 2.0 to 9.4 bar with the 41.5 keV $^{83m}$Kr peak. The reduced EL yield $Y/p$ was fitted linearly, revealing a modest ($\sim$5%) increase in slope starting around 5 bar and rising with pressure, addressing inconsistencies in past literature on the pressure dependence of this slope.
arXivarXiv · · April 17, 2026
0
0
AIRPET: Virtual Positron Emission Tomography
J. RennerJ. J. Gómez-CadenasR. Soleti
AIRPET is a web-based platform that integrates the three major stages of PET scanner design—detector simulation, image reconstruction, and image interpretation—into a single AI-assisted workflow. It provides an interface to large language models for geometry creation and a basic reconstruction interface, lowering the barrier for individuals or small teams to manage the full design pipeline. The paper introduces AIRPET and outlines its current and proposed functionality.
arXivarXiv · · January 29, 2026
0
A journey to ITACA: Ion Tracking with Ammonium Cations Apparatus
J. J. Gómez-CadenasL. AraziM. ElorzaZ. FreixaF. MonrabalA. PazosJ. RennerS. R. SoletiS. Torelli
The paper proposes ITACA, a method that augments gas xenon electroluminescent (EL) time projection chambers by introducing trace NH$_3$ (≈100 ppb) to convert primary Xe$^+$ ions into NH$_4^+$ ions. While electrons drift to the anode and produce a standard EL image, the slow NH$_4^+$ ions drift toward the cathode, where a sensor captures them at the projected event barycenter. Laser interrogation of the sensor’s molecular layer yields an ion-track image with sub-millimeter diffusion and no EL blurring. Combined electron-ion topological discrimination improves background rejection by about an order of magnitude in $0\nu\beta\beta$ searches.
arXivarXiv · · December 9, 2025
0
Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector
NEXT CollaborationM. Pérez Maneiro…J. Renner
The NEXT-100 high-pressure xenon TPC achieves sub-percent energy resolution, critical for the neutrinoless double-beta decay ($\beta\beta0\nu$) search. Calibrated with a Th-228 source, the detector demonstrates $(0.90 \pm 0.02)\%$ FWHM resolution at the 2615-keV Tl-208 photopeak, extrapolating to $(0.93 \pm 0.02)\%$ FWHM at the $Q_{\beta\beta}$ = 2458-keV decay endpoint, confirming its design goal of <1% FWHM.
arXivarXiv · · November 4, 2025
0
3
CRYSP: a Total-Body PET based on cryogenic cesium iodide crystals
S. R. SoletiP. DietzR. EsteveJ. Garcìa-BarrenaV. HerreroF. LopezF. MonrabalL. Navarro-CozcolluelaE. OblakJ. PelegrìnJ. RennerJ. Toledo  +2
CRYSP proposes a total-body PET design using cryogenic pure cesium iodide (CsI) monolithic crystals as a cost-effective alternative to expensive rare-earth scintillators. At around 100 K, CsI achieves a light yield of ~10^5 photons/MeV, enabling energy resolution below 7%, nanosecond-level coincidence time resolution, and millimeter-scale 3D spatial resolution via depth-of-interaction capability. This combination of high performance and reduced detector cost could make total-body PET more accessible for clinical and research use.
arXivarXiv · · July 13, 2025
0
2
The NEXT-100 Detector
NEXT CollaborationC. Adams…J. Renner
The NEXT-100 detector, a high-pressure gas electroluminescent time projection chamber for studying double beta decays of $^{136}$Xe, began data-taking at the Laboratorio Subterráneo de Canfranc in May 2024. It achieves exceptional energy resolution ($\leq 1\%$ FWHM at the $Q_{\beta\beta}$ value) and topological event discrimination using two sensor planes. Commissioning with argon and xenon gases demonstrated stable operation, with alpha decays from the $^{222}$Rn chain confirming a constant electron lifetime. This paper details the detector design, assembly, radiopurity budget, and commissioning results.
arXivarXiv · · May 23, 2025
0
19
High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber
NEXT CollaborationC. Adams…J. Renner
The NEXT-100 neutrinoless double-beta-decay experiment uses a time projection chamber that requires tens of kilovolts to drift electrons over meter-scale distances. This paper describes the cathode feedthrough and high-voltage distribution through the field cage. The feedthrough withstands up to 20 bar and -65 kV, and the TPC operates stably at its design voltages within a stringent radiopurity budget, enabling sensitive double-beta-decay analyses.
arXivarXiv · · May 2, 2025
0
1
Performance of an Optical TPC Geant4 Simulation with Opticks GPU-Accelerated Photon Propagation
NEXT CollaborationI. Parmaksiz…J. Renner
This paper evaluates Opticks, a GPU-accelerated photon propagation tool based on NVIDIA OptiX API 7.5, against a single-threaded Geant4 simulation using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Opticks accelerates simulation speeds by 58.47–181.39 times relative to the CPU-only Geant4 simulation, with speedups depending on the GPU and CPU types. The number of detected photons, their times, and wavelengths agree closely between the two methods, validating Opticks as a faster alternative for optical photon simulations.
arXivarXiv · · February 18, 2025
0
3
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
NEXT CollaborationM. Martínez-Vara…J. Renner
For a future xenon gas detector that can precisely locate the decay vertex, this paper studies the accuracy of reconstructing kinematic observables in neutrinoless double beta decay. Under realistic conditions (10 bar gas pressure, 4 mm spatial resolution), the average opening angle between the two electrons and the average single-electron energy can be measured with precisions of 0.19 and 110 keV, respectively, assuming only 10 detected events. This demonstrates the feasibility of distinguishing different lepton-number-violating mechanisms beyond light neutrino exchange.
arXivarXiv · · February 14, 2025
0
2
Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers
T. ContrerasB. Palmeiro…J. Renner
Using $^{83m}\text{Kr}$ data from the NEXT-White detector, this work measures the energy resolution achievable with silicon photomultipliers (SiPMs) for future neutrinoless double beta decay searches. The obtained full-width half-maximum resolution of $(10.9 \pm 0.6)\%$ is slightly larger than predictions from photon statistics, attributed to incomplete corrections. SiPM noise is not a dominant factor and can be made negligible with appropriate subtraction. These results support the development of SiPM-only readout planes that combine imaging capability with energy resolution comparable to that of conventional photomultiplier tubes.
arXivarXiv · · May 30, 2024
0
3
Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in 136^{136}Xe
NEXT CollaborationN. Byrnes…J. Renner
This paper demonstrates selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment, a key step for barium tagging in neutrinoless double beta decay searches in $^{136}$Xe. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with a 1x1 cm$^2$ scan area, operating inside 10 bar of xenon gas.
arXivarXiv · · May 20, 2024
0
11
Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector
J.HaefnerK.E.Navarro…J.Renner
The paper demonstrates event position reconstruction in the NEXT-White detector by quantifying electron diffusion in a high-pressure xenon gas TPC, without relying on primary scintillation timing. For low-energy $^{83\mathrm{m}}$Kr point-like deposits ($E\sim45$keV), the drift distance is determined to 2~cm precision with bias $<1$mm. A convolutional neural network applied to longer tracks ($E\geq1.5$MeV) achieves 3~cm precision on the event barycenter. These results support sub-1% FWHM energy calibration at $Q_{\beta\beta}$ and enable fiducialization in future large detectors.
arXivarXiv · · November 6, 2023
0
5
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
NEXT CollaborationP. Novella…J. Renner
The NEXT experiment demonstrates neutrinoless double beta decay ($0\nu\beta\beta$) searches in gaseous xenon using the NEXT-White detector. With a 1% FWHM energy resolution at 2.6 MeV and topological background rejection, the analysis combines 271.6 days of $^{136}$Xe-enriched and 208.9 days of $^{136}$Xe-depleted data. Two analysis methods—a background-model-dependent approach and a direct background-subtraction technique—yield 90% C.L. lower limits on the half-life in the range $T_{1/2}^{0\nu} > 5.5\times10^{23} - 1.3\times10^{24}$ yr, using a fiducial mass of $3.50\pm0.01$ kg of $^{136}$Xe-enriched xenon. This serves as a proof-of-concept for larger NEXT detectors.
arXivarXiv · · May 16, 2023
0
55
Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness
J. HaefnerA. Fahs…J. Renner
The authors measure the reflectance of PTFE coated with TPB at 200, 260, and 450 nm in air and find that at 450 nm the reflectance is approximately 92% for thicknesses from 5 mm to 10 mm, with negligible variation within this range. A cross-check in an argon chamber at 128 nm confirms that reducing thickness from 10 mm to 5 mm does not significantly affect light response. This indicates that thinner TPB-coated PTFE can be used in particle physics detectors without compromising the light signal.
arXivarXiv · · November 9, 2022
0
8
Shear and bulk acceleration viscosities in simple fluids
J. RennerM. SchmidtD. de las Heras
In simple fluids, viscous damping of inhomogeneities extends beyond the standard velocity-based Navier-Stokes description. Using molecular and overdamped Brownian dynamics simulations, this work demonstrates that analogous shear and bulk viscous effects act on the acceleration field, governed by the field's divergence and curl. These acceleration viscosities are quantitatively described by simple exponentially decaying memory kernels, enabling the characterization of fast dynamics on molecular time scales through the simultaneous use of velocity and acceleration fields.
arXivarXiv · · March 4, 2022
0
Ba2+^{2+} ion trapping by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector
P. Herrero-GómezJ.P. Calupitan…J. Renner
The paper demonstrates that Ba$^{2+}$ ions can be chelated in vacuum by an organic fluorescent bicolour indicator (FBI) molecule immobilized on a surface, using surface science techniques on Au(111). This trapping mechanism is also shown to work on a technologically relevant substrate, establishing the feasibility of using FBI molecules as building blocks for a Ba$^{2+}$ detector. Such a detector could tag the Ba$^{2+}$ dication produced in neutrinoless double beta decay of $^{136}$Xe, potentially enabling a nearly background-free experiment.
arXivarXiv · · January 22, 2022
0
Measurement of the 136{}^{136}Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT
NEXT CollaborationP. Novella…J. Renner
The NEXT collaboration reports a measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life using a novel direct background subtraction technique. By comparing data from NEXT-White with ${}^{136}$Xe-enriched and -depleted xenon, and leveraging the topology of double-electron tracks, they disentangle signal from background without relying on a background model. From a fiducial mass of 3.5 kg of Xe, they obtain a half-life of $2.34^{+0.80}_{-0.46}\mathrm{(stat)}^{+0.30}_{-0.17}\mathrm{(sys)}\times10^{21}~\mathrm{yr}$, demonstrating the feasibility of background-model-independent neutrinoless double beta decay searches.
arXivarXiv · · November 22, 2021
0
The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers
NEXT CollaborationB.J.P. Jones…J. Renner
This paper develops new analytic and computational methods for modeling radio-frequency (RF) carpet ion transport in gases at atmospheric pressures and above, where buffer gas collisions dominate. The central contribution is an analytic description of levitating and sweeping forces from phased arrays, combined with thermodynamic and kinetic principles to calculate ion loss rates. Validation against SIMION simulations is provided, and the method is applied to transport barium ions in xenon (1–10 bar) for neutrinoless double beta decay experiments, revealing challenges with current manufacturing techniques.
arXivarXiv · · September 8, 2021
0
16
Supernova Model Discrimination with Hyper-Kamiokande
Hyper-Kamiokande CollaborationK. Abe…J. Renner
Using a newly developed high-precision event generator, this paper simulates Hyper-Kamiokande's response to the first 500 ms of the neutrino burst from a galactic core-collapse supernova at distances up to 100 kpc. It shows that the detector can distinguish between five different supernova models with high accuracy, providing a tool to guide simulations toward the correct explosion mechanism.
arXivarXiv · · January 13, 2021
0
124
Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment
NEXT CollaborationM. KekicC. AdamsK. WoodruffJ. RennerE. ChurchM. Del TuttoJ.A. Hernando MorataJ.J. Gomez-CadenasV. AlvarezL. AraziI.J. Arnquist  +79
This paper demonstrates that deep convolutional neural networks (CNNs) can improve background rejection for neutrinoless double-beta decay searches in the NEXT experiment. Using 2.6-MeV gamma rays from a $^{228}$Th source in a high-pressure xenon TPC, the authors created electron-positron pair production events with a topology similar to the signal. By training on Monte Carlo simulations with on-the-fly data augmentation, the CNN became robust to simulation-data differences, achieving better signal efficiency and background rejection than previous non-CNN-based methods.
arXivarXiv · · September 22, 2020
0
54
Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air
S. GhoshJ. Haefner…J. Renner
This paper measures the dependence of polytetrafluoroethylene (PTFE) diffuse reflectance on thickness in air at 260 nm and 450 nm. For thicknesses from 5 mm to 10 mm, reflectance ranges from 90.0% to 92.0% at 260 nm and 92.5% to 94.5% at 450 nm. Spatial variation within a single piece of PTFE can reach 2.7%. Placing a specular reflector behind the PTFE recovers visible reflectance loss without adding a specular component.
arXivarXiv · · July 13, 2020
0
18
Sensitivity of the NEXT experiment to Xe-124 double electron capture
G. Martínez-LemaM. Martínez-Vara…J. Renner
The NEXT collaboration reports the sensitivity of its NEXT-White detector to the two-neutrino double electron capture ($2\nu ECEC$) of $^{124}$Xe, a Standard-Model-allowed process relevant as a benchmark for a future neutrinoless mode search. Using simulated $2\nu ECEC$ signal events and real background data from NEXT-White operated with $^{124}$Xe-depleted gas, an optimal event selection is defined. The analysis extrapolates to NEXT-100, showing that with 1 kg of $^{124}$Xe-enriched xenon over 5 years, a sensitivity to the $2\nu ECEC$ half-life of $6 \times 10^{22}$ y (90% confidence level) can be achieved.
arXivarXiv · · June 12, 2020
0
10
Processing of Compton events in the PETALO readout system
J. RennerJ.M. Benlloch-RodríguezJ.V. CarriónR. GadeaV. Herrero-BoschM. KekicC. Romo-LuqueP. FerrarioJ. J. Gómez-Cadenas
The PETALO detector uses liquid xenon as a scintillator for PET. This simulation study demonstrates that a neural network can tag 511 keV gamma rays whose reconstruction is degraded by Compton scattering, distinguishing them from Compton events that are still well reconstructed. The approach shows promise for recovering image quality, but an online implementation requires further study.
arXivarXiv · · January 14, 2020
0
Coherent Elastic Neutrino-Nucleus Scattering at the European Spallation Source
D. BaxterJ.I. Collar…J. Renner
This paper shows that the European Spallation Source (ESS) will provide the largest pulsed neutrino flux, roughly an order of magnitude larger than the source used for the first CEνNS detection, due to its high-power spallation target. Innovative detector technologies are described that can exploit this flux for high-statistics, precision CEνNS measurements, enabling access to a rich particle physics phenomenology.
arXivarXiv · · November 2, 2019
0
152
Radiogenic backgrounds in the NEXT double beta decay experiment
NEXT CollaborationP. Novella…J. Renner
This paper characterizes radiogenic backgrounds in the NEXT double beta decay experiment using 37.9 days of data from NEXT-White. A total background rate of (0.84±0.02) mHz above 1000 keV is measured. Radon abatement shows airborne-Rn contribution is negligible. A spectral fit to a radiopurity-based model identifies specific contributions from ⁶⁰Co, ⁴⁰K, ²¹⁴Bi, and ²⁰⁸Tl to this rate. After topological cuts, the rate reduces to (0.25±0.01) mHz, enabling a 3.5σ median sensitivity to two-neutrino double beta decay after one year. In a Q_ββ±100 keV window, only one event is observed against (0.75±0.12) expected, validating the model for NEXT-100.
arXivarXiv · · May 31, 2019
0
43
Demonstration of the event identification capabilities of the NEXT-White detector
NEXT CollaborationP. FerrarioJ.M. Benlloch-RodríguezG. Díaz LópezJ.A. Hernando MorataM. KekicJ. RennerA. UsónJ.J. Gómez-CadenasC. AdamsV. ÁlvarezL. Arazi  +79
The NEXT-White detector, the first underground detector of the NEXT experiment, demonstrates its ability to identify double-electron events from single-electron backgrounds using a topological cut. With a \TO\ calibration source producing events near 1.6 MeV, the cut achieves a signal efficiency of $71.6\%$ for a background acceptance of $20.6\%$, matching Monte Carlo simulations. Simulated extrapolation to the 0νββ region further improves background rejection over lower energies, enhancing experimental sensitivity.
arXivarXiv · · May 30, 2019
0
46
Electron Drift and Longitudinal Diffusion in High Pressure Xenon-Helium Gas Mixtures
A.D. McDonaldK. Woodruff…J. Renner
This paper reports new measurements of electron drift velocity and longitudinal diffusion coefficients in pure xenon and xenon-helium gas mixtures, at 1--9 bar and 50--300 V/cm. In pure xenon, excellent agreement with world data is found for both quantities at all $E/P$, except that a larger longitudinal diffusion coefficient than theory appears at low $E/P$. A similar effect occurs in mixtures at somewhat higher $E/P$. While drift velocities in mixtures are well predicted, longitudinal diffusion exceeds predictions, but extrapolation indicates that helium additives remain promising for reducing transverse diffusion.
arXivarXiv · · February 14, 2019
0
34
Frequent collaborators
F. Monrabal (59)
R. Esteve (56)
P. Ferrario (56)
M. Sorel (54)
J. Hauptman (53)
J. Torrent (53)
J. Martín-Albo (48)
V. Álvarez (46)
A. Simón (45)
A. Goldschmidt (45)
L. Labarga (43)
S. Cárcel (42)