Measurement of the neutron capture cross-section on argon
V. FischerL. PaganiL. PickardACA. CoutureS. GardinerC. GrantJ. HeT. JohnsonE. PanticC. ProkopR. SvobodaJ. Ullmann +1
V. Fischer
L. Pagani
L. Pickard
ACA. Couture
S. Gardiner
C. Grant
J. He
T. Johnson
E. Pantic
C. Prokop
R. Svoboda
J. Ullmann
+13
The neutron capture cross-section on argon is a key parameter for neutrino and dark matter detectors that use argon as a detection or shielding medium. Because previous measurements disagreed and were averaged over thermal spectra, this work provides a differential measurement using a time-of-flight neutron beam and a gamma spectrometer. A fit to the cross-section from 0.015–0.15 eV, assuming a $1/v$ energy dependence, gives $\sigma^{2200} = 673 \pm 26 \text{ (stat.)} \pm 59 \text{ (sys.)}$ mb.

arXiv ·
· February 2, 2019