MCP
KH

K. Han

106 papers in the library

Papers

30
End-to-End Data Analysis Methods for the CUORE Experiment
D. Q. AdamsC. Alduino…K. Han
The CUORE experiment, a ton-scale array of cryogenic calorimeters operating at ~10 mK, achieved the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te. This work describes the end-to-end analysis tools and methods developed for CUORE, treating each calorimeter independently for optimization, data acquisition, and analysis. The core contribution is the detailed evaluation of the energy-dependent detector response and signal efficiency used in the latest $0\nu\beta\beta$ decay search, enabling high-quality datasets for multiple rare-event searches.
arXivarXiv · · October 29, 2025
0
3
Reconstruction of cosmic-ray muon events with CUORE
CUORE CollaborationD. Q. Adams…K. Han
By using the segmentation of the CUORE cryogenic detector array, a multi-objective optimization algorithm achieves in-situ 3D reconstruction of through-going cosmic-ray muons without time-of-flight estimation. The integral muon flux measured underground at the Laboratori Nazionali del Gran Sasso agrees with other experiments. This work is the first demonstration of 3D particle tracking with per-event angular determination in a millikelvin detector, critical for validating muon-related background in next-generation neutrinoless double-beta decay experiments.
arXivarXiv · · September 5, 2025
0
0
Sensitivity of neutrinoless double beta decays from a combined analysis of ground and excited states
C. R. DingK. HanS. B. WangJ. M. Yao
The sensitivity of next-generation neutrinoless double-beta ($0\nu\beta\beta$) decay experiments, targeting half-lives up to $10^{28}$ years, is limited by uncertain nuclear matrix elements (NMEs). This work proposes a combined analysis of $0\nu\beta\beta$ decays to both the ground state and the first excited $0^+$ state of the daughter nucleus. This multi-channel strategy can significantly enhance sensitivity, depending on NME predictions, and is well-suited for large liquid xenon detectors like PandaX-xT and XLZD using $^{136}$Xe.
arXivarXiv · · August 24, 2025
0
Exploring the keV-scale physics potential of CUORE
CUORE CollaborationD. Q. Adams…K. Han
This paper reports the keV-scale analysis of the CUORE experiment using over 2 tonne yr of data. By applying stricter selection to optimize thresholds at 10 keV and 3 keV, the analysis achieves average baseline resolutions of 2.54 ± 0.14 keV and 1.18 ± 0.02 keV FWHM, respectively. The overall background is reduced by about an order of magnitude, reaching 2.06 ± 0.05 counts/(keV kg days) at 10 keV and 16 ± 2 counts/(keV kg days) at 3 keV. Near-threshold reconstruction efficiencies are evaluated for the first time, yielding 50 ± 2 % at 10 keV and 26 ± 4 % at 3 keV, demonstrating the scalability of tonne-scale cryogenic calorimeters for low-energy physics.
arXivarXiv · · May 29, 2025
0
5
The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
D. Q. AdamsC. Alduino…K. Han
Using data from the CUORE experiment and the Copernicus Earth Observation program, this study reports the first detection of marine microseismic vibrations with mK-scale calorimeters. The analysis reveals seasonal Mediterranean Sea activity that impacts CUORE's energy thresholds, resolution, and sensitivity over four years, underscoring the need to address faint environmental noise in ultra-sensitive experiments. The paper also demonstrates a noise decorrelation algorithm using auxiliary sensors that reduces vibrational noise and improves detector performance.
arXivarXiv · · May 13, 2025
0
3
Sensitivity of the CUPID experiment to 0I^½I^2I^20νββ decay of 100^{100}Mo
K. AlfonsoA. Armatol…K. Han
CUPID, a next-generation bolometric experiment using 1596 Li$_2$MoO$_4$ crystals at ~10 mK in the CUORE cryostat, searches for neutrinoless double-beta decay of $^{100}$Mo. With a background of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM energy resolution at the Q-value, its Bayesian 90% credible interval exclusion sensitivity gives a half-life $′T_{1/2} > 1.6 \times 10^{27}$ yr, corresponding to an effective Majorana neutrino mass $′m_{\beta\beta} < 9.6$--$28$ meV; the Frequentist 3σ discovery sensitivity is $′T_{1/2}= 1.0 \times 10^{27}$ yr, corresponding to $′m_{\beta\beta}= 12$--$36$ meV.
arXivarXiv · · April 19, 2025
0
Half-life and precision shape measurement of 2νββ decay of 130^{130}Te
D. Q. AdamsC. Alduino…K. Han
Using 1038 kg yr of CUORE data, the $2\nu\beta\beta$ half-life of $^{130}$Te is measured as $(9.32^{+0.05}_{-0.04}(\text{stat.})^{+0.07}_{-0.07}(\text{syst.}))\times10^{20}$ yr, doubling previous precision. The improved signal-to-background ratio enables the first application of the enhanced $2\nu\beta\beta$ formalism to $^{130}$Te, yielding an effective axial coupling credibility interval and higher-order nuclear matrix element ratios. The second-to-first ratio agrees with models, while the third-to-first deviates, providing nuclear model tests relevant to $0\nu\beta\beta$ searches.
arXivarXiv · · March 31, 2025
0
Search for fractionally charged particles with CUORE
CUORE CollaborationD. Q. Adams…K. Han
The Cryogenic Underground Observatory for Rare Events (CUORE), a 988-crystal TeO$_2$ array operating below 20 mK, is used to search for fractionally charged particles (FCPs) with charges between $e/24$ and $e/5$. Using the first tonne-year of exposure, no significant excess of FCP candidate tracks is found, leading to the most stringent limits on the underground FCP flux in this charge range at 90% confidence level. This work demonstrates the sensitivity of tonne-scale sub-Kelvin detectors to exotic particle signatures.
arXivarXiv · · June 18, 2024
0
15
Data-driven background model for the CUORE experiment
CUORE CollaborationD. Q. Adams…K. Han
We present a data-driven background model for the CUORE experiment, built from a Bayesian fit to energy spectra across a broad range using 1038.4 kg yr of exposure. The model exploits detector granularity, exposure, and operational stability to resolve spatial and time-dependent backgrounds, achieving sensitivity to bulk activities as low as 10 nBq kg$^{-1}$ and surface activities as low as 0.1 nBq cm$^{-2}$. The extracted contamination levels are compared with prior radio-assay data, informing future background mitigation strategies for CUORE and the CUPID experiment.
arXivarXiv · · May 28, 2024
0
36
Constraints on Lepton Number Violation with the 2 tonne⋅\cdotyr CUORE Dataset
CUORE CollaborationD. Q. Adams…K. Han
The CUORE experiment searches for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te using a tonne-scale cryogenic calorimeter at milli-kelvin temperatures. With over 2 tonne$\cdot$year TeO$_2$ exposure, no evidence of $0\nu\beta\beta$ is found, yielding a lower limit on the half-life of $T_{1/2} > 3.5 \times 10^{25}$ years (90% C.I.). This result and the stable operation of nearly 1000 detectors demonstrate infrastructure for future searches.
arXivarXiv · · April 5, 2024
0
11
Tunable Magnetic Properties in Sr2_2FeReO6_6 Double-Perovskite
Z.T. ZhangH. YanZ. HuangX. ChiC.J. LiZ.S. LimS.W. ZengK. HanG.J. OmarK.X. JinA. Ariando
This paper shows that the magnetic properties of epitaxial Sr$_2$FeReO$_6$ double-perovskite films can be tuned by both oxygen deposition pressure and lattice mismatch. In a nearly strain-free film on SrTiO$_3$, reducing the oxygen pressure to 30 mTorr triggers a ferrimagnetic-to-paramagnetic transition, attributed to the formation of Re$^{4+}$ ions disrupting $B$-site ordering. Applying compressive strain shifts this critical pressure below 1 mTorr, while tensile strain raises it above 40 mTorr, demonstrating epitaxial strain as an additional control knob.
arXivarXiv · · April 26, 2023
0
Twelve-crystal prototype of Li2_2MoO4_4 scintillating bolometers for CUPID and CROSS experiments
CUPIDCROSS collaborations…K. Han
This paper reports the construction and long-term operation of a twelve-crystal array of Li$_2$MoO$_4$ scintillating bolometers, each 0.28 kg, equipped with 16 Ge light detectors, to optimize detector design for the CROSS and CUPID double-beta decay experiments. The study systematically varied phonon sensor size, Ge detector shape and supplier, and light collection conditions (reflector and surface coating). The array ran for eight months in a low-background cryostat at Canfranc, achieving sensitivity to radioactive contamination at the $\mu$Bq/kg level for $^{228}$Th and $^{226}$Ra.
arXivarXiv · · April 10, 2023
0
20
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
CUPID collaborationK. Alfonso…K. Han
This paper reports the first test of CUPID-design bolometric light detectors with NTD-Ge sensors inside a pulse-tube cryostat, a setting that introduces strong mechanical vibrations. Each of the four tested detectors achieved a baseline noise well below the CUPID goal of 100 eV RMS, with measured values of 70–90 eV RMS. One detector reached an energy resolution of 0.71(5) keV FWHM at the 356 keV line of a $^{133}$Ba source, the best reported for any gamma detector in that energy range. The results validate the detector design for the CUPID neutrinoless double-beta decay experiment.
arXivarXiv · · April 10, 2023
0
14
New direct limit on neutrinoless double beta decay half-life of 128^{128}Te with CUORE
D. Q. AdamsC. Alduino…K. Han
The CUORE experiment, a ton-scale cryogenic detector searching for neutrinoless double beta ($0\nu\beta\beta$) decay in $^{130}$Te, reports its first results for $^{128}$Te. No evidence of decay is found. A Bayesian analysis sets a lower limit on the half-life of $T_{1/2} > 3.6 \times 10^{24}$ yr (90% CI), the most stringent direct limit, improving over previous direct searches by a factor of 30 and surpassing geochemical constraints for the first time.
arXivarXiv · · May 6, 2022
0
0
Toward CUPID-1T
A. ArmatolC. Augier…K. Han
This paper outlines the roadmap toward CUPID-1T, a next-to-next generation ton-scale calorimetric experiment that targets a sensitivity to the neutrinoless double-beta decay half-life beyond $10^{28}$ years and $m_{\beta\beta}\lesssim 15$ meV, covering the Inverted Ordering region and exploring the Normal Ordering parameter space. The work reviews ongoing projects in background reduction, cryogenic readout, and beyond-$0\nu\beta\beta$ physics that underpin this detector.
arXivarXiv · · March 16, 2022
0
15
Search for Neutrinoless β+ECβ^+EC Decay of 120^{120}Te with CUORE
D. Q. AdamsC. Alduino…K. Han
This paper reports a search for neutrinoless positron-emitting electron capture ($0\nu\beta^+EC$) decay in $^{120}$Te using the CUORE detector. With a total TeO$_2$ exposure of 355.7 kg·yr (0.2405 kg·yr of $^{120}$Te), the analysis exploited the detector's modularity by including events with different topology and performing a simultaneous fit of five selected signal signatures. No evidence of signal was found, yielding a 90% credibility interval Bayesian lower limit of $2.9 \times 10^{22}$ yr on the $^{120}$Te half-life, improving the previous limit by an order of magnitude.
arXivarXiv · · March 16, 2022
0
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
J. AalbersK. Abe…K. Han
This review article argues that a next-generation dual-phase xenon time-projection chamber will serve as a multi-purpose observatory, advancing dark matter and neutrino physics. It is the leading technology for probing Weakly Interacting Massive Particles (WIMPs) and other dark matter candidates, while also enabling studies of neutrinoless double-beta decay and astrophysical neutrinos. The paper presents the science cases for such a detector, highlighting its potential contributions to particle physics, nuclear physics, astrophysics, solar physics, and cosmology.
arXivarXiv · · March 4, 2022
1
255
Optimization of the first CUPID detector module
CUPID collaborationA. Armatol…K. Han
The CUPID experiment, which searches for neutrinoless double beta decay, tested its first optimized detector module. The module uses scintillating Li$_2^{100}$MoO$_4$ crystals coupled to light detectors; simultaneous heat and light detection rejects the dominant alpha-particle background. A new detector structure and light sensor design improved light collection over past measurements. The heat detectors achieved an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV), and the particle identification capability ensured alpha rejection above 99.9%, meeting CUPID requirements.
arXivarXiv · · February 13, 2022
0
32
Energy-Aware Edge Association for Cluster-based Personalized Federated Learning
Y. LiX. QinH. ChenK. HanP. Zhang
This paper addresses clustered personalized federated learning over wireless networks by jointly optimizing edge association, user clustering, and resource management. The central contribution is an iterative solution that uses deep reinforcement learning at the cloud server to minimize total energy consumption across base stations while maximizing averaged model accuracy. The approach requires no prior knowledge of model parameters and, according to simulations, achieves accurate learning at lower energy cost than existing methods.
arXivarXiv · · February 6, 2022
0
38
Observation of perfect diamagnetism and interfacial effect on the electronic structures in Nd0.8Sr0.2NiO2 superconducting infinite layers
S. W. ZengX. M. YinC. J. LiL. E. ChowC. S. TangK. HanZ. HuangY. CaoD. Y. WanZ. T. ZhangZ. S. LimC. Z. Diao  +4
This paper reports the observation of perfect diamagnetism in Nd0.8Sr0.2NiO2 infinite-layer thin films, definitively confirming their superconductivity. By studying films of different thicknesses, the authors demonstrate that the interface and strain effects modify the electronic structure. In films thinner than 5.5 nm, the Hall coefficient remains negative, indicating a thickness-driven band structure change. X-ray absorption spectroscopy shows enhanced Ni-O hybridization with decreasing thickness, and band structure calculations on the nickelate/SrTiO3 heterostructure explain this by an interface-induced dominating electron-like band, which causes the Hall-coefficient sign change.
arXivarXiv · · April 29, 2021
0
Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE
D. Q. AdamsC. Alduino…K. Han
The CUORE experiment searches for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{130}$Te using cryogenic calorimeters operating at 10 mK. No evidence for the decay is found, yielding a lower bound on the half-life of $T_{1/2}^{0\nu} > 2.2 \times 10^{25}$ years at 90% credibility. The results constrain the Majorana nature of neutrinos, and the advances in maintaining large mass at ultra-low temperature with low radioactivity are relevant to other fields.
arXivarXiv · · April 14, 2021
0
306
Search for Double-Beta Decay of 130Te\mathrm{^{130}Te} to the 0+0^+ States of 130Xe\mathrm{^{130}Xe} with CUORE
CUORE CollaborationD. Q. Adams…K. Han
The CUORE experiment searches for neutrino-less double beta decay ($0\nu\beta\beta$) of $^{130}\mathrm{Te}$ to the first $0^+_2$ excited state of $^{130}\mathrm{Xe}$. Using 372.5 kg$\times$yr TeO$_2$ exposure, no significant evidence for either $0\nu\beta\beta$ or Standard Model-allowed two-neutrino double beta decay ($2\nu\beta\beta$) to this state was found. Bayesian lower bounds at 90% C.I. set half-life limits of $ (T_{1/2})^{0\nu}_{0^+_2} > 5.9 \times 10^{24}$ yr and $ (T_{1/2})^{2\nu}_{0^+_2} > 1.3 \times 10^{24}$ yr, the most stringent limits on double beta decay of $^{130}\mathrm{Te}$ to excited states, improving previous results by a factor of $\sim5$.
arXivarXiv · · January 26, 2021
0
Room-temperature colossal magnetoresistance in terraced single-layer graphene
J.X. HuJ. GouM. YangG. J. OmarJ. Y. TanS. W. ZengY. P. LiuK. HanZ. S. LimZ. HuangA. T. S. WeeA. Ariando
This paper reports a room-temperature colossal magnetoresistance (MR) of up to 5,000% at 9 T in terraced single-layer graphene. By laminating graphene on a terraced substrate (e.g., TiO₂-terminated SrTiO₃), the MR is enhanced by one order of magnitude over conventional single-layer graphene devices. The terraced structure is shown to be the dominant factor driving the enhancement, with a colossal MR >1,000% even at a high carrier density of ~10¹² cm⁻².
arXivarXiv · · January 19, 2021
0
55
Measurement of the 2νββνββ Decay Half-life of 130^{130}Te with CUORE
CUORE CollaborationD. Q. Adams…K. Han
Using a 300.7 kg$\cdot$yr exposure from the CUORE detector, the two-neutrino double beta decay half-life of $^{130}$Te was measured via a Bayesian analysis that disentangled background sources from the signal. The result, $T_{1/2}^{2\nu} = 7.71^{+0.08}_{-0.06}(\mathrm{stat.})^{+0.12}_{-0.15}(\mathrm{syst.})\times10^{20}$ yr, agrees with prior measurements but achieves the most precise determination to date.
arXivarXiv · · December 21, 2020
0
Characterization of cubic Li2_{2}100^{100}MoO4_4 crystals for the CUPID experiment
A. ArmatolE. Armengaud…K. Han
The CUPID Collaboration characterized cubic Li$_2$$^{100}$MoO$_4$ crystals as an alternative to the cylindrical ones used in CUPID-Mo, motivated by their suitability for tightly packed arrays. The cubic crystals achieved an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. The baseline design's $α$ particle identification was shown to fully suppress this background, and the data validated a Monte Carlo model for further detector optimization.
arXivarXiv · · November 27, 2020
0
A CUPID Li2_{2}100^{100}MoO4_4 scintillating bolometer tested in the CROSS underground facility
CUPID Interest GroupA. Armatol…K. Han
A cubic Li$_2$$^{100}$MoO$_4$ scintillating bolometer (45 mm side) with a Ge wafer was tested in the CROSS cryogenic facility at Canfranc, achieving 6 keV FWHM energy resolution at the 2615 keV $\gamma$ line and $\sim8\sigma$ separation between $\gamma(\beta)$ and $\alpha$ events above 2 MeV. The crystal also shows high internal radiopurity ($^{228}$Th $<3\ \mu$Bq/kg, $^{226}$Ra $<8\ \mu$Bq/kg). This demonstration supports the use of cubic Li$_2$$^{100}$MoO$_4$ bolometers in the CROSS and CUPID $0\nu2\beta$ experiments.
arXivarXiv · · November 27, 2020
0
38
New results from the CUORE experiment
A. GiacheroD. Q. Adams…K. Han
CUORE, a one-ton-scale cryogenic detector using 988 TeO₂ crystals, finds no evidence for neutrinoless double-beta decay of ¹³⁰Te. Based on 372.5 kg·yr of exposure, it sets a Bayesian 90% credibility lower limit of 3.2×10²⁵ yr on the half-life, with a median exclusion sensitivity of 1.7×10²⁵ yr. The paper also reviews detector performance, the background model, and the measured two-neutrino double-beta decay half-life.
arXivarXiv · · November 18, 2020
0
8
Artificial two-dimensional polar metal by charge transfer to a ferroelectric insulator
W. X. ZhouH. J. WuJ. ZhouS. W. ZengC. J. LiM. S. LiR. GuoJ. X. XiaoZ. HuangW. M. LvK. HanP. Yang  +11
This paper reports the coexistence of polarity and two-dimensional conductivity—two properties normally considered mutually exclusive—in a ferroelectric Ba$_{0.2}$Sr$_{0.8}$TiO$_3$ thin film at the LaAlO$_3$/Ba$_{0.2}$Sr$_{0.8}$TiO$_3$ interface at room temperature. The ~3.2 nm film retains its polarization while hosting a two-dimensional mobile carrier density of ~0.05 electron per unit cell. This unusual conducting polar phase arises from electronic reconstruction driven by competition between the built-in electric field of LaAlO$_3$ and the polarization of Ba$_{0.2}$Sr$_{0.8}$TiO$_3$.
arXivarXiv · · July 12, 2020
0
40
Improved Limit on Neutrinoless Double-Beta Decay in 130^{130}Te with CUORE
CUORE CollaborationD. Q. Adams…K. Han
The CUORE collaboration reports an improved search for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}$Te using a 372.5 kg$\cdot$yr exposure, a fourfold increase over previous data. No evidence for decay is found, yielding a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the half-life. Assuming light Majorana neutrinos, this corresponds to an effective Majorana mass upper limit of 75–350 meV, depending on nuclear matrix elements.
arXivarXiv · · December 23, 2019
0
Results of CUORE
S. Dell&#39;OroD. Q. Adams…K. Han
CUORE, the world's largest bolometric experiment using 988 TeO2 crystals (742 kg total mass), has been searching for the neutrinoless double beta decay of 130Te since 2017. Its initial science run set the most stringent limit on the neutrinoless double beta decay half-life of 130Te and achieved the most precise measurement of the two-neutrino double beta decay half-life. With more than double the initial exposure collected, this contribution reports updated results on these key measurements from the ongoing experiment.
arXivarXiv · · May 19, 2019
0
0
Frequent collaborators
G. Bari (47)
F. Bellini (47)
C. Brofferio (47)
C. Bucci (47)
S. Capelli (47)
L. Cardani (47)
O. Cremonesi (47)
I. Dafinei (47)
F. Ferroni (47)
C. Nones (47)
L. Pattavina (47)
M. Pavan (47)