MCP
KL

K. Lung

19 papers in the library

Papers

19
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
E. AprileF. Agostini…K. Lung
The XENON1T dark matter detector requires a two-order-of-magnitude background reduction relative to XENON100. A water Cherenkov muon veto, 10 m in height and diameter, with 8-inch photomultipliers and reflective foil, was designed and optimized via Monte Carlo simulations. The central contribution is the demonstration that this veto achieves >99.5% efficiency for muons and >70% for muon-induced secondary showers, making muon-induced neutron backgrounds negligible for XENON1T.
arXivarXiv · · June 9, 2014
0
150
First Axion Results from the XENON100 Experiment
XENON100 CollaborationE. Aprile…K. Lung
The XENON100 experiment reports the first direct search for axions and axion-like-particles using the axio-electric effect in liquid xenon. With 224.6 live days and a 34 kg fiducial exposure, no signal was found. The strongest limit to date is set on the axion-electron coupling $g_{Ae}$: below $7.7 \times 10^{-12}$ (90% CL) for solar axions, and below $1 \times 10^{-12}$ (90% CL) for axion-like-particles constituting the entirety of galactic dark matter in the 1--40 keV/$c^2$ mass range. Under the DFSZ and KSVZ models, QCD axions heavier than 0.3 eV/$c^2$ and 80 eV/$c^2$ are excluded, respectively.
arXivarXiv · · April 5, 2014
0
226
Observation and applications of single-electron charge signals in the XENON100 experiment
E. AprileM. Alfonsi…K. Lung
The XENON100 experiment reports the observation of single-electron charge signals unrelated to WIMP interactions. These signals arise from photoionization of impurities in liquid xenon and metal components in the time projection chamber. They serve as a unique calibration source, enabling the inference of secondary-scintillation gain, extraction yield, and electron drift velocity, thus demonstrating the detector's excellent sensitivity to small charge signals.
arXivarXiv · · November 5, 2013
0
158
The neutron background of the XENON100 dark matter experiment
E.AprileM.Alfonsi…K.Lung
The XENON100 experiment, located at LNGS, directly searches for WIMP dark matter via elastic scattering off xenon nuclei. This paper characterizes the nuclear recoil background from neutrons produced by (α,n) and spontaneous fission reactions from natural radioactivity in detector and shield materials, plus muon-induced neutrons. Using Monte Carlo simulations and measured radioactive contaminations, the study predicts the neutron background for the 2011 and 2012 WIMP search results: 0.11$^{+0.08}_{-0.04}$ and 0.17$^{+0.12}_{-0.07}$ events, concluding that this background does not limit the experiment's sensitivity.
arXivarXiv · · June 10, 2013
0
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
XENON100 CollaborationE. Aprile…K. Lung
This paper reports the nuclear recoil calibration of the XENON100 dark matter detector using an external $^{241}\text{AmBe}$ neutron source. The data are compared with a detailed Monte Carlo simulation to extract the energy-dependent charge yield $Q_y$ and relative scintillation efficiency $L_{\text{eff}}$. Excellent spectral matching is achieved in the scintillation (S1) and ionization (S2) channels, as well as in the two-dimensional particle discrimination space. The results validate the signal acceptance used in the experiment's previous dark matter searches.
arXivarXiv · · April 4, 2013
0
110
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
XENON100 collaborationE. Aprile…K. Lung
Using 224.6 live days × 34 kg of exposure from the XENON100 experiment, we report the most stringent upper limits on the spin-dependent WIMP-neutron cross section for WIMP masses above 6 GeV. No signal from axial-vector interactions with $^{129}$Xe and $^{131}$Xe nuclei was observed, yielding a minimum cross section of $3.5 \times 10^{-40} \text{ cm}^2$ at a WIMP mass of 45 GeV (90% confidence level).
arXivarXiv · · January 28, 2013
0
503
The distributed Slow Control System of the XENON100 Experiment
E. AprileM. Alfonsi…K. Lung
This paper describes the Slow Control System (SCS) of the XENON100 dark matter experiment, emphasizing its distributed, modular architecture. The system, implemented in Java following object-oriented principles, continuously monitors hundreds of parameters from dozens of instruments in real time and sets emergency alarms. The SCS has been operating remotely since mid 2008, maximizing flexibility and code reusability.
arXivarXiv · · November 5, 2012
0
11
Expected Sensitivity to Galactic/Solar Axions and Bosonic Super-WIMPs based on the Axio-electric Effect in Liquid Xenon Dark Matter Detectors
K. ArisakaP. BeltrameC. GhagJ. KaidiK. LungA. LyashenkoR. D. PecceiP. SmithK. Ye
This paper demonstrates that future ton-scale liquid xenon detectors, originally designed for WIMP dark matter, could also detect axions and bosonic super-WIMPs via the axio-electric effect on xenon atoms. With one ton-year exposure, the sensitivity to galactic axions (non-relativistic dark matter) reaches a coupling $g_{Ae} > 10^{-14}$ at $1\,\text{keV}/c^2$ (or $10^{-13}$ at $100\,\text{keV}/c^2$); for solar axions, sensitivity is $g_{Ae} \sim 10^{-12}$ below a few $\text{keV}/c^2$, independent of mass. The irreducible neutrino background from pp-chain solar neutrinos and $^{136}\text{Xe}$ double beta decay is the only limiting factor. Vector-boson dark matter could be detected for coupling $\alpha'/\alpha > 10^{-33}$ (at $1\,\text{keV}/c^2$) or $>10^{-27}$ (at $100\,\text{keV}/c^2$).
arXivarXiv · · September 17, 2012
0
62
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
XENON CollaborationE. Aprile…K. Lung
This comment refutes Sorensen's claim that XENON100's spin-independent WIMP-nucleon cross-section upper limits below 10 GeV may be understated by an order of magnitude or more. The authors report that their own detailed analysis, performed before submitting their new result, does not confirm Sorensen's findings. They explain their rationale for excluding the described effect from their final analysis and list several potential problems with his study.
arXivarXiv · · August 28, 2012
0
0
Dark Matter Results from 225 Live Days of XENON100 Data
XENON100 CollaborationE. Aprile…K. Lung
The XENON100 experiment, operating at LNGS, searched for dark matter with 224.6 live days × 34 kg exposure. With an ultra-low electromagnetic background of $(5.3 \pm 0.6) \times 10^{-3}$ events (kg day keVee)$^{-1}$, a blind analysis found two candidate events in the 6.6–30.5 keVnr range, consistent with the background expectation of $1.0 \pm 0.2$ events. A Profile Likelihood analysis over 6.6–43.3 keVnr set the most stringent limit on spin-independent WIMP-nucleon scattering cross sections for WIMP masses above 8 GeV/$c^2$, reaching a minimum of $2 \times 10^{-45}$ cm$^2$ at 55 GeV/$c^2$ (90% CL).
arXivarXiv · · July 25, 2012
0
2k+
Analysis of the XENON100 Dark Matter Search Data
XENON100 CollaborationE. Aprile…K. Lung
The paper presents the general analysis methods developed for the XENON100 dark matter search, which uses a dual-phase xenon time projection chamber to detect WIMP-nucleon interactions. These methods, applied to the 100.9 and 224.6 live-day science runs, underlie the reported results on spin-independent elastic, spin-dependent elastic, and inelastic WIMP-nucleon cross-sections, providing the technical framework for the experiment's dark matter constraints.
arXivarXiv · · July 14, 2012
0
117
Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches
T. AlexanderD. Alton…K. Lung
The DarkSide-10 detector, a two-phase liquid argon TPC prototype with 10 kg of active argon, was operated underground at Gran Sasso. Its scintillation light yield was measured using gamma-ray full-absorption peaks and single-photoelectron calibrations. For gamma lines from 122 to 1275 keV, the average yield is 8.887 ± 0.003(stat) ± 0.444(sys) p.e./keVee. After additional purification, the yield at 511 keV increased to 9.142 ± 0.006(stat) p.e./keVee, confirming the importance of light yield for background rejection via pulse shape discrimination.
arXivarXiv · · April 27, 2012
0
3
Characterization of the Hamamatsu R11410-10 3-Inch Photomultiplier Tube for Liquid Xenon Dark Matter Direct Detection Experiments
K. LungK. ArisakaA. BargetziP. BeltrameA. CahillT. GenmaC. GhagD. GordonJ. SainzA. TeymourianY. Yoshizawa
This paper characterizes the Hamamatsu R11410-10 photomultiplier tube, developed for next-generation dual-phase TPC dark matter detectors. High quantum efficiency (>30%), low dark count rate (50 Hz at 0.3 PE), and high gain ($10^7$) with good single photoelectron resolution are demonstrated. The manufacturer quotes a radioactivity of 20 mBq/PMT. These results indicate the R11410-10 is suitable for zero-background liquid xenon detectors.
arXivarXiv · · February 13, 2012
0
A New Analysis Method for WIMP searches with Dual-Phase Liquid Xe TPCs
K. ArisakaP. BeltrameC. GhagK. LungP. R. Scovell
This paper presents a new analysis method for WIMP dark matter searches using dual-phase liquid xenon TPCs. Traditionally, nuclear recoil energy is estimated from the prompt scintillation signal S1, while the ionization signal C2 (or its secondary scintillation S2) is used only for electron recoil discrimination. The authors argue that C2 is a more reliable energy estimator than S1. They introduce the phase space Log(S1/C2) vs. C2, which improves nuclear recoil acceptance and energy resolution without sacrificing discrimination, 3D reconstruction, or fiducialization. They also propose two independent energy estimators, E2 (primary, based on C2) and E1 (secondary, based on S1), and show that Log(E1/E2) vs. E2 is optimal for evaluating WIMP candidates.
arXivarXiv · · February 9, 2012
0
Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors
K. ArisakaP. BeltrameC. W. LamP. F. SmithC. GhagD. B. ClineK. LungY. MengE. PanticP. R. ScovellA. TeymourianH. Wang
This paper proposes a three-stage dark matter and neutrino observatory using multi-ton two-phase liquid Xe and Ar detectors in a 5:1 mass ratio. The central contribution is a scalable design that achieves WIMP sensitivity down to $10^{-47}\,\text{cm}^2$ and provides two independent WIMP mass measurements from the two target elements. External and internal backgrounds are reduced to $<1$ event per year per stage via self-shielding, enabling pp solar neutrino measurement, supernova neutrino detection, and $^{136}\text{Xe}$ neutrinoless double beta decay searches at $10^{27}$–$10^{28}$ years lifetime. The staged approach reuses Ar vessels for successive Xe detectors, requiring only one new vessel per stage.
arXivarXiv · · July 7, 2011
0
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
XENON100 CollaborationE. Aprile…K. Lung
Using 100.9 live-days of XENON100 data, this paper reports limits on the WIMP-nucleon cross section for inelastic dark matter. With three observed events in the signal region (expected background $1.8 \pm 0.6$), the results rule out, at 90% confidence level, the inelastic dark matter scattering off iodine as an explanation for the DAMA/LIBRA modulation.
arXivarXiv · · April 15, 2011
0
102
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 CollaborationE. Aprile…K. Lung
The XENON100 experiment, a two-phase time projection chamber with a 62 kg liquid xenon target installed underground, found no evidence for dark matter in 100.9 live days of data. Three candidate events were observed in a pre-defined signal region against an expected background of $1.8 \pm 0.6$ events. This null result sets the most stringent limit on dark matter interactions at the time, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above $7.0 \times 10^{-45}$ cm$^2$ for a WIMP mass of 50 GeV/$c^2$ at 90% confidence level.
arXivarXiv · · April 13, 2011
0
1k+
Characterization of the QUartz Photon Intensifying Detector (QUPID) for Noble Liquid Detectors
A. TeymourianD. AharoniL. BaudisP. BeltrameE. BrownD. ClineA.D. FerellaA. FukasawaC.W. LamT. LimK. LungY. Meng  +5
The QUartz Photon Intensifying Detector (QUPID), an ultra-low-background photodetector made entirely of ultraclean synthetic fused silica, fulfills the radioactivity requirements for next-generation zero-background experiments, as verified by screening at the Gran Sasso Gator facility. At room temperature, quantum efficiency exceeds 30% at the xenon scintillation wavelength. At low temperatures, it exhibits leakage current below 1 nA, a gain of 10^5, and >95% linearity for cathode up to 1 μA and anode up to 3 mA. The photocathode and collection efficiency show 80% uniformity over the entire surface. Timing response includes 1.8 ns rise time and 160 ps transit time spread. Scintillation light from 57Co and 210Po sources was observed in liquid xenon.
arXivarXiv · · March 18, 2011
0
28
Study of the electromagnetic background in the XENON100 experiment
XENON100 CollaborationE. Aprile…K. Lung
The XENON100 experiment, located at LNGS, aims to directly detect dark matter WIMPs. This paper presents a comprehensive study of the predicted electronic recoil background from radioactive decays. Using GEANT4 Monte Carlo simulations with detailed detector geometry and measured radioactivity of all components, the background in the WIMP-search energy range (0-100 keV) within the 30 kg fiducial mass is predicted to be less than $10^{-2}$ events/(kg-day-keV). This prediction, consistent with the design goal, agrees very well with commissioning data from Fall 2009.
arXivarXiv · · January 20, 2011
0
150
Frequent collaborators
K. Arisaka (18)
A. Teymourian (16)
P. Beltrame (15)
E. Pantic (15)
H. Wang (15)
L. Baudis (13)
E. Brown (13)
E. Aprile (12)
F. Arneodo (12)
A. Behrens (12)
K. Bokeloh (12)
S. Fattori (12)