MCP
LF

L. Figini

4 papers in the library

Papers

4
Planck LFI flight model feed horns
F. VillaO. D'ArcangeloM. PecoraL. FiginiR. NestiA. SimonettoC. SozziM. SandriP. BattagliaP. GuzziM. BersanelliR.C. Butler  +1
This paper describes the design, manufacturing, and testing of the 11 corrugated feed horns that optically interface the Planck Low Frequency Instrument (LFI) with the ESA Planck telescope. The horns were designed to optimize the LFI optical interfaces while satisfying the stringent mechanical requirements of the Planck focal plane layout. All eleven flight-model units were successfully tested and integrated with the Ortho Mode Transducers.
arXivarXiv · · January 26, 2010
0
The PLANCK LFI flight model ortho-mode transducers
O. D'ArcangeloA. SimonettoL. FiginiE. PaganaF.VillaM. PecoraP. BattagliaM. BersanelliR.C. ButlerS. GaravagliaP. GuzziN. Mandolesi  +1
The Planck LFI uses 22 ultra-sensitive pseudocorrelation radiometers at 30, 44, and 70 GHz to measure CMB anisotropy and polarization. Intrinsic polarization sensitivity is achieved by Ortho-Mode Transducers (OMTs) that separate incoming radiation into two linear orthogonal components. A set of 11 flight-model OMTs (2 at 30 GHz, 3 at 44 GHz, 6 at 70 GHz) was developed through an Elegant Bread Board and Qualification Model campaign. The paper reports that all flight units were accepted and their electromagnetic performance is at least marginally compliant with requirements, with mechanical qualification passed after a rework.
arXivarXiv · · January 26, 2010
0
16
The Planck-LFI flight model composite waveguides
O. D'ArcangeloL. FiginiA. SimonettoF.VillaM. PecoraP. BattagliaM. BersanelliR.C. ButlerF. CuttaiaS. GaravagliaP. GuzziN. Mandolesi  +4
The Planck-LFI composite waveguides (WGs) connect the 20 K Front End Modules to the 300 K Back End Modules. A stainless-steel/copper composite design was selected to satisfy conflicting thermal, electromagnetic, and mechanical requirements: minimizing heat load while limiting signal attenuation. The WGs, 1.5–2 m long, were manufactured and tested. Their measured performance meets the requirements, and they were successfully space qualified.
arXivarXiv · · January 26, 2010
0
12
Planck pre-launch status: Design and description of the Low Frequency Instrument
M. BersanelliN. Mandolesi…L. Figini
This paper describes the design and scientific requirements of the Planck Low Frequency Instrument (LFI), a 20-K cryogenic array of differential microwave radiometers using Indium Phosphide HEMT amplifiers and 4-K blackbody reference loads. LFI will map the full sky in intensity and polarization at 30, 44, and 70 GHz to complement the higher-frequency HFI instrument in precision imaging of the cosmic microwave background.
arXivarXiv · · January 19, 2010
0
308
Frequent collaborators
O. D'Arcangelo (4)
M. Pecora (4)
A. Simonetto (4)
P. Battaglia (4)
P. Guzzi (4)
M. Bersanelli (4)
N. Mandolesi (4)
C. Sozzi (3)
R.C. Butler (3)
S. Garavaglia (3)
F. Villa (2)
R. Nesti (2)