MCP
LL

L Lorini

6 papers in the library

Papers

6
Polarizabilities of the 87Sr Clock Transition
C ShiJ.-L RobyrU EismannM ZawadaL LoriniR Le TargatJ Lodewyck
This paper reviews the vector and tensor polarizabilities of the two energy levels of the ${}^{87}\text{Sr}$ clock transition, whose measurement was reported in 2011. A theoretical calculation reproduces the measured coefficients. The experimental conditions used in two Sr optical lattice clocks are detailed, and the quadratic dependence of the vector and tensor shifts on the trapping potential depth is exhibited, with an evaluation of their impact on clock accuracy.
arXivarXiv · · March 31, 2015
0
Experimenting an optical second with strontium lattice clocks
R. Le TargatL. LoriniY. Le CoqM. ZawadaJ. GuénaM. AbgrallM. GurovP. RosenbuschD. G. RoveraB. NagórnyR. GartmanP. G. Westergaard  +8
This work demonstrates that two strontium optical lattice clocks agree within their accuracy budget at a total uncertainty of $1.6\times 10^{-16}$, and their comparison with three independent caesium fountain clocks yields a reproducibility limited only at $3.1\times 10^{-16}$ by the best microwave realizations of the SI second. These results show that optical clocks have surpassed the caesium fountains used to define the second, providing a key step toward a redefinition of the unit of time.
arXivarXiv · · January 25, 2013
0
Bayesian estimate of the zero-density frequency of a Cs fountain
D CalonicoF LeviL LoriniG Mana
The paper presents a Bayesian analysis that estimates the zero-density frequency of a Cs fountain clock by incorporating the known sign of the collisional coefficient as prior knowledge. Compared to the orthodox analysis, this method reduces the uncertainty of the frequency estimate by 28% when applied to data from the INRIM caesium fountain, demonstrating its value in primary frequency metrology.
arXivarXiv · · July 28, 2009
0
Bayesian inference of a negative quantity from positive measurement results
D CalonicoF LeviL LoriniG Mana
This paper applies Bayesian inference to assign a probability density to a quantity that is known to be negative, based on positive measurement results. The analysis yields a posterior density that is logically consistent with both positive and negative measurement outcomes, and is used to estimate the atom density shift in a caesium fountain clock. The advantages of this Bayesian approach for the realization of the time unit are discussed.
arXivarXiv · · February 17, 2009
0
Black Body Radiation Shift of the 133Cs Hyperfine Transition Frequency
S. MicalizioA. GodoneD. CalonicoF. LeviL. Lorini
This paper theoretically evaluates the static scalar polarizability of the $^{133}$Cs ground state and the black-body radiation (BBR) shift of the hyperfine transition frequency (with $m_F=0$). The computed polarizability is $\alpha_0 = 6.600(16) \times 10^{-39} \,\mathrm{C\,m^2/V}$, agreeing with recent results at the $10^{-3}$ level. The relative BBR shift at $300\,\mathrm{K}$ is $\beta = -1.49(7) \times 10^{-14}$, which is $2 \times 10^{-15}$ lower than the previously accepted value derived from dc-Stark measurements.
arXivarXiv · · October 17, 2003
0
Measurement of the Blackbody Radiation Shift of the 133Cs Hyperfine Transition in an Atomic Fountain
F. LeviD. CalonicoL. LoriniS. MicalizioA. Godone
The authors report a measurement of the blackbody radiation shift of the cesium ground-state hyperfine transition (9.2 GHz) using an atomic fountain frequency standard. The measured relative shift at 300 K is $(-1.43 \pm 0.11) \times 10^{-14}$, which agrees with their theoretical evaluation $(-1.49 \pm 0.07) \times 10^{-14}$ but differs from the previously accepted value $(-1.69 \pm 0.04) \times 10^{-14}$. This discrepancy has implications for the accuracy of frequency standards and high-precision physics tests.
arXivarXiv · · October 13, 2003
0
Frequent collaborators
D Calonico (2)
F Levi (2)
G Mana (2)
S. Micalizio (2)
A. Godone (2)
D. Calonico (2)
F. Levi (2)
C Shi (1)
J.-L Robyr (1)
U Eismann (1)
M Zawada (1)
R Le Targat (1)