MCP
LL

Lie Lin

7 papers in the library

Papers

7
Acoustic diagnostics of femtosecond laser filamentation
Binpeng ShangNan ZhangPengfei QiShishi TaoLie LinWeiwei Liu
The paper reports acoustic diagnostics of femtosecond laser filamentation in air. Acoustic power shows a quadratic dependence on laser energy, and the acoustic spectrum bandwidth correlates positively with energy deposition. The spectrum of the acoustic pulse from the middle of the filament has a larger bandwidth than from the ends, indicating filament intensity distribution. These findings enable the study of filament dynamics through acoustic parameters, aiding remote-sensing applications.
arXivarXiv · · July 11, 2023
0
8
Femtosecond Laser Filamentation in Atmospheric Turbulence
Jiewei GuoLu SunYuezheng WangJiayun XueZhi ZhangHaiyi LiuShishi TaoPengfei QiLie LinWeiwei Liu
This paper experimentally investigates how atmospheric turbulence affects femtosecond laser filaments. Ultrasonic signals from filaments show that increasing turbulence intensity and expanding the turbulence region increase the filament's starting position and decrease its length, consistent with theory. Atmospheric turbulence also expands the filament's spot size and, at sufficient intensity, induces multiple filaments. Under the experimental parameters, the standard deviation of the filament's transverse displacement is proportional to the square root of the turbulent structure constant $C_n^2$.
arXivarXiv · · June 27, 2023
0
Coupled air lasing gain and Mie scattering loss: aerosol effect in filament-induced plasma spectroscopy
Jiayun XueZhi ZhangYuezheng WangBinpeng ShangJiewei GuoShishi TaoNan ZhangLanjunguoPengfei QiLie LinWeiwei Liu
This paper establishes a physical model for filament-induced aerosol fluorescence that couples Mie scattering loss with amplified spontaneous emission gain. The model, validated by experiments showing the dependence of backward fluorescence on the interaction length between filament and aerosols, reveals how aerosols affect both excitation and propagation in femtosecond laser filament-induced plasma spectroscopy (FIPS). This work clarifies the combined aerosol effect on the overall FIPS process, advancing its practical application in atmospheric remote sensing.
arXivarXiv · · June 22, 2023
0
Filament based Ionizing Radiation Sensing Technology
Weiwei LiuJiewei GuoNan ZhangLu SunHaiyi LiuShihi TaoYuezheng WangBinpeng ShangPengfei QiLie Lin
This paper proposes a filament-based ionizing radiation sensing technology (FIRST) that uses femtosecond laser filaments to remotely detect ionizing radiation. The authors demonstrate that energetic electrons and ions from alpha radiation act as seed electrons, accelerated within the filament to markedly enhance nitrogen fluorescence, with an extended lifetime of ~1 ns. This provides a mechanism for remote sensing, overcoming the limited range of traditional detectors.
arXivarXiv · · June 9, 2023
0
0
Remote Sensing of Trace Element in Sea Salt Aerosol with Sensitivity Level of 10 pg/m3
Yuezheng WangNan ZhangJiayun XueBingpeng ShangJiewei GuoZhi ZhangPengfei QiLie LinWeiwei Liu
We present a remote femtosecond laser filamentation system for detecting trace elements in sea salt aerosols. By using a terawatt-class laser and optimizing the filament–aerosol interaction length, the system achieves a Na+ detection limit of 0.015 ng/m³ at 30 m, improving to 0.006 ng/m³ with a deep learning algorithm. This sensitivity is orders of magnitude below the 10 ng/m³ requirement for aerosol monitoring.
arXivarXiv · · June 9, 2023
0
Sub-ppb aerosol detection at a distance of 30 meters by millijoule femtosecond laser pulse filamentation in air
Jiewei GuoZhi ZhangNan ZhangBinpeng ShangJiayun XueYuezheng WangShishi TaoBofu XieLanjun GuoLie LinWeiwei Liu
This work demonstrates sub-ppb aerosol detection at 30 m using a millijoule femtosecond laser filament. A 41.4 cm off-axis concave mirror focuses the beam and collects NaCl aerosol fluorescence. By making the laser beam strike the mirror non-symmetrically, astigmatism is reduced, increasing filament intensity by 69.5× and lowering the detection limit 86 % to 0.32 ppb. The central contribution is the improved excitation scheme that compensates off-axis aberration through deliberate beam-spot asymmetry, enabling sensitive remote detection of airborne particles.
arXivarXiv · · January 27, 2023
0
1
Spectral Domain Z-scan Technique
Xi ZengPengfei QiPin ChenLie LinWeiwei Liu
The spectral-domain Z-scan technique measures the nonlinear refractive index by converting wavefront phase shifts into spectral changes rather than far-field spatial patterns. This method is designed for highly scattering media, where conventional Z-scan fails due to roughness constraints. Its feasibility relies on the fact that Mie scattering efficiency is nearly wavelength-insensitive when the roughness is much larger than the wavelength. The technique was validated by measuring nonlinear refraction of polished and frosted slides, yielding results consistent with previous reports.
arXivarXiv · · April 9, 2020
0
Frequent collaborators
Weiwei Liu (7)
Pengfei Qi (6)
Nan Zhang (5)
Jiewei Guo (5)
Yuezheng Wang (5)
Binpeng Shang (4)
Shishi Tao (4)
Jiayun Xue (4)
Zhi Zhang (4)
Lu Sun (2)
Haiyi Liu (2)
Lanjunguo (1)