MCP
MA

M. Ahn

4 papers in the library

Papers

4
Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT
M. AdhikariM. AhnD. Amaya MatamorosP. S. BarbeauV. BelovI. BernardiC. BockA. BolozdynyaR. BouabidA. BrachoJ. BrowningB. Cabrera-Palmer  +94
The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering (CEvNS) cross section to date, using its germanium detector array (Ge-Mini) at the Spallation Neutron Source. With an exposure of $4.68\times10^{22}$ protons on target, they observed $124^{+14}_{-12}$ counts and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(stat)} \pm 0.10 \mathrm{(sys)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood neutrino source enables independent rate measurements for muon and electron neutrinos, which refine constraints on heavy-particle-mediated non-standard neutrino interactions.
arXivarXiv · · March 18, 2026
0
12
The COHERENT Experiment: 2026 Update
M. AdhikariM. AhnD. Amaya MatamorosP. S. BarbeauV. BelovI. BernardiC. BockA. BolozdynyaR. BouabidJ. BrowningB. Cabrera-PalmerN. Cedarblade-Jones  +98
The COHERENT experiment measures coherent elastic neutrino-nucleus scattering (CEvNS) and other neutrino-nucleus cross sections using multiple nuclear targets at the Spallation Neutron Source. Its 2026 update reports that after several successful CEvNS measurements with tens-of-kg detectors, the next phase aims for percent-level precision through lower thresholds, reduced backgrounds, larger detector masses, and benchmarking the neutrino flux. New detectors including lighter targets (sodium, neon) will test the expected $N^2$ cross-section dependence. Additionally, inelastic cross sections below $50\,\mathrm{MeV}$—critical for core-collapse supernova interpretation—will be measured for the first time.
arXivarXiv · · February 17, 2026
0
4
Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT's Germanium Array
S. AdamskiM. AhnP. S. BarbeauV. BelovI. BernardiC. BockA. BolozdynyaR. BouabidJ. BrowningB. Cabrera-PalmerN. Cedarblade-JonesA. I. Colón Rivera  +76
The COHERENT collaboration reports the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium using the Ge-Mini detector at the Spallation Neutron Source. With an analysis threshold of 1.5 keVee and a total exposure of 10.22 GWhkg, they observe a beam-on excess of $20.6^{+7.1}_{-6.3}$ counts, rejecting the no-CEvNS hypothesis at 3.9 sigma significance. The measured rate agrees with the Standard Model prediction within 2 sigma.
arXivarXiv · · June 19, 2024
0
58
The CDFII Time-Of-Flight Detector and Impact on Beauty Flavor Tagging
C.GrozisR.Kephart…M.Ahn
The CDFII Time-of-Flight (TOF) detector, fully operational since August 2001, uses plastic scintillator bars and fine-mesh photomultipliers to achieve a design resolution of $100\,\mathrm{ps}$. This provides at least $2\sigma$ separation between $K^{\pm}$ and $\pi^{\pm}$ for momenta $p<1.6\,\mathrm{GeV}/c$, complementing ionization-based identification. The paper describes the detector design, calibration status, and initial performance, and reviews its expected impact on flavor tagging of neutral $B_S$ mesons.
arXivarXiv · · September 13, 2002
0
6
Frequent collaborators
P. S. Barbeau (3)
V. Belov (3)
I. Bernardi (3)
C. Bock (3)
A. Bolozdynya (3)
R. Bouabid (3)
J. Browning (3)
B. Cabrera-Palmer (3)
N. Cedarblade-Jones (3)
A. I. Colón Rivera (3)
V. da Silva (3)
Y. Efremenko (3)