MCP
MB

M. Bała

7 papers in the library

Papers

7
Three-Photon Bayesian Imaging of Ortho-Positronium
L. RaczynskiW. KrzemienA. CoussatM. BalaB. C. HiesmayrK. KlimaszewskiM. ObaraR. Y. Shopa
The paper proposes TRIO, a three-photon event-by-event image reconstruction algorithm formulated as Bayesian maximum a posteriori inference that unifies time-based trilateration, energy-based reconstruction, and, for the first time, a physics-informed prior derived from the QED description of positronium decay. Unlike positronium lifetime imaging, which needs a prompt photon and thus specific radionuclides, TRIO relies solely on the three photons and is fully compatible with standard radionuclides such as 18F. In Monte Carlo simulations modelled after the Siemens Biograph Quadra scanner, TRIO achieves a mean position error of 1.65 cM, about 2.8 times better than time-based trilateration (4.59 cM) and about 5.3 times better than energy-based reconstruction alone (8.7 cM). The Bayesian approach is compatible with existing TOF-PET scanners that can register three-photon annihilation coincidences.
arXivarXiv · · July 30, 2026
0
0
Probing arbitrary polarized photon pairs undergoing double Compton scatterings by a dedicated MC simulator validated with experimental data
M. BalaW. KrzemienB. C. HiesmayrJ. BaranK. DulskiK. KlimaszewskiL. RaczynskiR. Y. ShopaW. Wislicki
Double Compton scattering provides a way to access polarization information for MeV photon pairs, where conventional polarizers are unavailable. This paper presents a Geant4-based Monte Carlo simulator (Vienna-Warsaw model) that can simulate arbitrary initial polarization states of bipartite photons. The model is validated against high-statistics experimental data from the J-PET Big Barrel detector, totaling $3 \times 10^5$ event candidates of positronium-decay photon pairs. The simulated spectra of the angular difference $\Delta\hat{\Phi}$ between the two scattering planes agree well with experimental correlation spectra and yield the squared visibility encoding polarization interference contrast.
arXivarXiv · · May 13, 2025
0
8
Quantum Error Channels in High Energetic Photonic Systems
B. C. HiesmayrW. KrzemieńM. Bała
The paper presents a framework based on quantum error-correction channels to describe the quantum information-theoretic content of 511 keV photons undergoing Compton scattering, characterized by the Klein–Nishina formula in unoriented matter. This formalism predicts the spatial distribution of multiple photons with arbitrary polarization and entanglement, and characterizes accessible versus inaccessible information. It also handles successive multi-photon scattering and all single- and multi-partite errors, providing a basis for reducing errors in PET imaging.
arXivarXiv · · October 16, 2023
0
5
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
P. MoskalT. BednarskiSz. NiedzwieckiM. SilarskiE. CzerwinskiT. KozikJ. ChhokarM. BałaC. CurceanuR. Del GrandeM. DadgarK. Dulski  +27
The J-PET 24-module prototype, a plastic-scintillator-strip scanner with a 300 mm axial field of view, demonstrates a cost-effective approach to total-body PET. Its triggerless DAQ and digital front-end required novel calibration for time, thresholds, and gain. The prototype achieves a coincidence resolving time of CRT = $490 \pm 9$ ps, yielding a position reconstruction accuracy of $\sigma(\Delta l) = 18$ mm that is largely position-independent.
arXivarXiv · · August 25, 2020
0
20
Assessing thermal spike model of swift heavy ion-matter interaction via Pd1−x_{1-x}Nix_x/Si interface mixing
Paramita PatraS. A. KhanM. BalaD. K. AvasthiS. K. Srivastava
The paper tests the thermal spike model (TSM) of swift heavy ion-matter interaction by measuring 100 MeV Au-induced mixing across Pd$_{1-x}$Ni$_x$/Si interfaces. The experimental mixing parameter $\Delta \sigma^2$ varies with Ni concentration $x$ as a concave-upward curve with a minimum. In contrast, $L^2$ (proportional to $\Delta \sigma^2$) calculated from TSM using density-functional-theory electron-phonon coupling increases monotonically with $x$, showing a clear discrepancy. The authors conclude that mechanisms beyond TSM plus transient molten-state diffusion may be involved.
arXivarXiv · · October 10, 2018
0
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
P. MoskalN. KrawczykB. C. HiesmayrM. BałaC. CurceanuE. CzerwińskiK. DulskiA. GajosM. GorgolR. Del GrandeB. JasińskaK. Kacprzak  +22
The J-PET detector, which registers 511 keV photons via Compton scattering in plastic scintillators, can determine the linear polarization of individual photons on an event-by-event basis. For a scattering angle of about 82°, the single-event polarization resolution is approximately 40°, but for samples exceeding ten thousand events, the relative average polarization can be determined to within a few degrees. This extends polarization measurements to the MeV energy range, five orders of magnitude beyond the optical regime, enabling studies of quantum entanglement and discrete symmetries in positronium decays.
arXivarXiv · · September 27, 2018
0
82
Processing optimization with parallel computing for the J-PET tomography scanner
W. KrzemieńM. BałaT. BednarskiP. BiałasE. CzerwińskiA. GajosM. GorgolB. JasińskaD. KamińskaŁ. KapłonG. KorcylP. Kowalski  +18
This paper discusses parallel computing methods applied to optimize data processing for the J-PET tomography scanner, a novel TOF-PET detector based on long polymer scintillators. The authors begin with general concepts of parallel computing and then describe several applications of these techniques within the J-PET data processing pipeline, addressing the high computational demands of the triggerless data acquisition mode.
arXivarXiv · · August 11, 2015
0
Frequent collaborators
B. C. Hiesmayr (5)
K. Klimaszewski (4)
R. Y. Shopa (4)
L. Raczynski (3)
W. Krzemien (3)
K. Dulski (3)
W. Krzemień (3)
P. Moskal (3)
M. Silarski (3)
T. Kozik (3)
A. Gajos (3)
M. Gorgol (3)