MCP
MB

M. Buchner

6 papers in the library

Papers

6
Direct imaging of the ac component of the pumped spin polarization with element specificity
S. PileM. BuchnerV. NeyT. SchaffersK. LenzR. NarkowiczJ. LindnerH. OhldagA. Ney
Using time-resolved scanning transmission X-ray microscopy, the ac component of spin polarization pumped from a permalloy microstrip into adjacent Co-doped ZnO is directly imaged with element specificity and spatial resolution. The dynamic magnetization of the two materials is found to be antiphase. The spin polarization in the nonferromagnet extends laterally beyond the ferromagnetic strip, suggesting local pumping efficiency and micrometer-scale lateral propagation of the ac spin polarization.
arXivarXiv · · May 15, 2020
0
Extracting the Dynamic Magnetic Contrast in Time-Resolved X-ray Transmission Microscopy
T. SchaffersT. FeggelerS. PileR. MeckenstockM. BuchnerD. SpoddigV. NeyM. FarleH. WendeS. WintzM. WeigandH. Ohldag  +2
This paper demonstrates that the dynamic magnetic contrast observed in time-resolved scanning transmission X-ray microscopy (STXM) behaves as the usual X-ray magnetic circular dichroism (XMCD) effect. By separating background contributions, the authors quantify the relative phase and precession opening angle of ferromagnetic resonance (FMR) up to 10 GHz with 20 nm spatial resolution. This establishes XMCD-based dynamic contrast as a tool for studying linear and nonlinear magnetic excitations in micro- and nanostructures.
arXivarXiv · · May 29, 2019
0
16
Phase noise due to vibrations in Mach-Zehnder atom interferometers
A. MiffreM. JacqueyM. BüchnerG. TrénecJ. Vigué
This paper develops a model for phase noise due to vibrations in Mach-Zehnder atom interferometers. The model is applied to a thermal lithium interferometer, where it explains the observed reduction in fringe visibility with increasing diffraction order. The authors argue that the dynamical model can help reduce vibration-induced phase noise, enabling new experiments.
arXivarXiv · · April 5, 2006
0
Anomalous cooling of the parallel velocity in seeded beams
A. MiffreM. JacqueyM. BuchnerG. TrenecJ. Vigue
The authors measured the parallel velocity distribution of a lithium beam seeded in argon and found its parallel temperature to be much lower than that of the argon carrier gas. They extended supersonic cooling theory to the high-dilution limit, deriving a formula for the seeded gas parallel temperature that matches their experimental observations. This work provides a theoretical explanation for the anomalous cooling of the parallel velocity of the seeded species.
arXivarXiv · · January 7, 2004
0
Optimization of a Langmuir-Taylor detector for lithium
R. DelhuilleA. MiffreE. LavalletteM. BüchnerC. RizzoG. TrénecJ. ViguéH. J. LoeschJ. P. Gauyacq
This paper presents the construction and optimization of a Langmuir-Taylor detector for lithium using a rhenium ribbon. The absolute detection probability is measured, and its dependence on oxygen pressure and surface temperature is studied. The measured ionization probability supports the Saha-Langmuir law, and rapid work function variations with oxygen pressure and temperature are explained by a chemical equilibrium model.
arXivarXiv · · March 13, 2002
0
High contrast Mach-Zehnder lithium atom interferometer in the Bragg regime
R. DelhuilleC. ChampenoisM. BuchnerL. JozefowskiC. RizzoG. TrenecJ. Vigue
A Mach-Zehnder atom interferometer using a supersonic lithium beam and first-order Bragg diffraction on laser standing waves achieves a fringe contrast of 74%, reported as the highest ever observed with atom interferometers. The apparatus, which produces a large signal, is intended for high-sensitivity measurements.
arXivarXiv · · November 8, 2001
0
Frequent collaborators
A. Miffre (3)
S. Pile (2)
V. Ney (2)
T. Schaffers (2)
H. Ohldag (2)
A. Ney (2)
M. Jacquey (2)
G. Trénec (2)
J. Vigué (2)
G. Trenec (2)
J. Vigue (2)
R. Delhuille (2)