MCP
MB

M. Burghoff

12 papers in the library

Papers

12
Measurement of the permanent electric dipole moment of the neutron
C. AbelS. AfachN. J. AyresC. A. BakerG. BanG. BisonK. BodekV. BondarM. BurghoffE. ChanelZ. ChowdhuriP.-J. Chiu  +72
We report a neutron electric dipole moment (EDM) measurement at the Paul Scherrer Institute using Ramsey's method with ultracold neutrons. The experiment employed a $^{199}$Hg co-magnetometer and cesium magnetometer array to control magnetic field changes. The result, $d_n = (0.0 \pm 1.1_{\text{stat}} \pm 0.2_{\text{sys}}) \times 10^{-26} e\,\text{cm}$, is consistent with zero and constrains time-reversal-violating physics beyond the Standard Model.
arXivarXiv · · January 31, 2020
0
1k+
New Limit on the Permanent Electric Dipole Moment of 129^{129}Xe using 3^{3}He Comagnetometry and SQUID Detection
N. SachdevaI. FanE. BabcockM. BurghoffT. E. ChuppS. DegenkolbP. FierlingerS. HaudeE. KraegelohW. KilianS. Knappe-GrünebergF. Kuchler  +11
This paper reports a new limit on the permanent electric dipole moment (EDM) of $^{129}$Xe, measured using $^{3}$He comagnetometry and SQUID detection. Both species are polarized by spin-exchange optical pumping, then their free precession is detected by SQUID magnetometers in applied electric and magnetic fields. Combining data from 2017 and 2018 campaigns, the result is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst})\times10^{-28}~e\,\mathrm{cm}$, yielding an upper limit $|d_A(^{129}\mathrm{Xe})| < 1.4 \times 10^{-27}~e\,\mathrm{cm}$ (95% CL), which is five times more sensitive than the previous best limit from 2001.
arXivarXiv · · September 26, 2019
0
A new measurement of the permanent electric dipole moment of 129^{129}Xe using 3^{3}He comagnetometry and SQUID detection
N. SachdevaI. FanE. BabcockM. BurghoffT. E. ChuppS. DegenkolbP. FierlingerE. KraegelohW. KilianS. Knappe-GrünebergF. KuchlerT. Liu  +9
A new measurement of the $^{129}$Xe electric dipole moment (EDM) uses $^{3}$He comagnetometry and SQUID detection. Both species are polarized via spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result is $d_A(^{129}\mathrm{Xe}) = (0.26 \pm 2.33_\mathrm{stat} \pm 0.72_\mathrm{syst})\times10^{-27}~e\,\mathrm{cm}$, yielding an upper limit $|d_A(^{129}\mathrm{Xe})| < 4.81\times 10^{-27}~e\,\mathrm{cm}$ (95% CL), a factor of 1.4 more sensitive than the previous limit.
arXivarXiv · · February 7, 2019
0
A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
J.M. PendleburyS. AfachN.J. AyresC.A. BakerG. BanG. BisonK. BodekM. BurghoffP. GeltenbortK. GreenW.C. GriffithM. van der Grinten  +38
This paper reanalyzes the experimental data that set the current world sensitivity limit on the neutron electric dipole moment (EDM). Incorporating improved understanding of gravity's effect on ultracold neutron depolarization, refined neutron spectrum calculations, and updated systematic error estimates, the analysis yields $d_\mathrm{n} = -0.21 \pm 1.82 \times 10^{-26} \, e\mathrm{cm}$. This implies a revised upper limit of $3.0 \times 10^{-26} \, e\mathrm{cm}$ (90% CL) or $3.6 \times 10^{-26} \, e\mathrm{cm}$ (95% CL).
arXivarXiv · · September 15, 2015
0
Constraining interactions mediated by axion-like particles with ultracold neutrons
S. AfachG. BanG. BisonK. BodekM. BurghoffM. DaumM. FertlB. FrankeZ. D. GrujićV. HélaineM. KasprzakY. Kermaïdic  +26
By precisely measuring the Larmor precession frequency ratio of ultracold neutrons and $^{199}$Hg atoms in the same volume under a $\sim1\mu$T vertical magnetic field, the authors constrain a possible short-range spin-dependent interaction mediated by axion-like particles. The interaction strength, proportional to the CP-violating product $g_Sg_P$, would cause a tiny frequency shift. This model-independent result improves limits from other neutron experiments by up to two orders of magnitude for interaction ranges $10^{-6}<\lambda<10^{-4}$ m.
arXivarXiv · · December 11, 2014
0
A measurement of the neutron to 199Hg magnetic moment ratio
S. AfachC.A. BakerG. BanG. BisonK. BodekM. BurghoffZ. ChowdhuriM. DaumM. FertlB. FrankeP. GeltenbortK. Green  +42
This paper reports a measurement of the neutron gyromagnetic ratio relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. Using an apparatus in which ultracold neutrons and mercury atoms are stored in the same volume, the authors obtain the result γn/γHg = 3.8424574(30). This ratio represents the central contribution of the work.
arXivarXiv · · October 30, 2014
0
60
A magnetically shielded room with ultra low residual field and gradient
I. AltarevE. BabcockD. BeckM. BurghoffS. ChesnevskayaT. ChuppS. DegenkolbI. FanP. FierlingerA. FreiE. GutsmiedlS. Knappe-Grüneberg  +20
This paper presents a portable two-layer magnetically shielded room that achieves a residual magnetic field of $(700 \pm 200)$ pT and a gradient below 300 pT/m in a 1 m³ central volume, improving the state of the art by more than a hundredfold. This performance enables next-generation fundamental-physics searches for electric dipole moments and Lorentz-invariance tests via spin-precession experiments. The analysis of residual field sources guides future ultra-low-gradient designs.
arXivarXiv · · March 25, 2014
0
128
An Improved Search for the Neutron Electric Dipole Moment
M. BurghoffA. SchnabelG. BanT. LefortY. LemiereO. Naviliat-CuncicE. PierreG. QuemenerJ. ZejmaM. KasprzakP. KnowlesA. Weis  +25
The paper reports an improved search for the neutron electric dipole moment (nEDM) at the Paul Scherrer Institute, using an upgraded version of the apparatus that set the current best experimental limit. The collaboration aims to achieve a sensitivity of $\\sigma(d_n)=2.6\\times10^{-27}~e\\text{cm}$, corresponding to an upper limit of $d_n < 5\\times10^{-27}~e\\text{cm}$ (95% C.L.) for a null result. Concurrently, a new apparatus is being designed to reach a further improved sensitivity of $\\sigma(d_n)=2.6\\times10^{-28}~e\\text{cm}$.
arXivarXiv · · October 7, 2011
0
4
Limit on Lorentz and CPT violation of the bound Neutron Using a Free Precession 3He/129Xe co-magnetometer
C. GemmelW. HeilS. KarpukK. LenzYu. SobolevK. TullneyM. BurghoffW. KilianS. Knappe-GrünebergW. MüllerA. SchnabelF. Seifert  +2
This paper reports a search for Lorentz and CPT violation by monitoring sidereal variations in the frequency difference of co-located 3He and 129Xe nuclear spins, detected with a free-precession co-magnetometer using SQUID sensors. As the Earth rotates relative to a relic background field, the experiment constrains the equatorial component of the field coupling to the bound neutron, yielding a limit of $b_n < 3.7 \times 10^{-32}$ GeV at 95% confidence level.
arXivarXiv · · November 9, 2010
0
Test of Lorentz Symmetry by using a 3He/129Xe Co-Magnetometer
K. TullneyC. GemmelW. HeilS. KarpukK. LenzYu. SobolevM. BurghoffW. KilianS. Knappe-GrünebergW. MüllerA. SchnabelF. Seifert  +2
A 3He/129Xe co-magnetometer was used to test Lorentz symmetry by searching for a background field coupling to the spin of bound neutrons. The experiment sets a preliminary upper limit on the equatorial component of that field at $b_n < 3.72 \times 10^{-32}$ GeV (95% C.L.).
arXivarXiv · · August 3, 2010
0
Ultra-sensitive magnetometry based on free precession of nuclear spins
C.GemmelW.HeilK.LenzCh.LudwigK.ThulleyYu.SobolevM.BurghoffS.Knappe-GruenebergW.KilianW.MuellerA.SchnabelF.Seifert  +2
This paper describes a low-field magnetometer that detects free spin precession of gaseous, nuclear-polarized $^{3}$He or $^{129}$Xe samples using a SQUID flux detector. The central contribution is its ultra-high sensitivity: with characteristic spin-precession times $T_2$ up to 60 h and a signal-to-noise ratio > 5000 : 1, it achieves $ΔB = 1$ fT after 220 s of integration and $ΔB = 10^{-4}$ fT after one day. The performance remains statistically limited, as the nuclear spins are nearly decoupled from the environment, making the magnetometer suitable for long-term stable precision field measurements.
arXivarXiv · · May 22, 2009
0
An Improved Neutron Electric Dipole Moment Experiment
M. KuźniakI. AltarevG. BanG. BisonK. BodekM. BurghoffM. DaumK. EberhardtP. FierlingerE. GutsmiedlG. HampelW. Heil  +32
This paper describes a new measurement of the neutron electric dipole moment (nEDM) at the Paul Scherrer Institute, aiming to reduce experimental uncertainty by two orders of magnitude. The improvement relies on the higher ultra-cold neutron flux from the new PSI source, better magnetic field control, and a double-chamber configuration with opposite electric fields. The first stage uses an upgraded apparatus from the previous best measurement, while the final accuracy requires a new spectrometer under design. A non-zero nEDM would violate CP symmetry, and the current upper limit already constrains some Standard Model extensions.
arXivarXiv · · June 30, 2008
0
Frequent collaborators
A. Schnabel (11)
G. Ban (6)
G. Bison (6)
W. Heil (6)
K. Kirch (6)
B. Lauss (6)
T. Lefort (6)
O. Naviliat-Cuncic (6)
D. Rebreyend (6)
S. Roccia (6)
N. Severijns (6)
J. Voigt (6)