Absolute frequency measurement of the 40Ca+ S1/2 - D5/2 clock transition
M. ChwallaJ. Benhelm
K. KimG. KirchmairT. MonzM. RiebeP. SchindlerA. S. VillarW. HaenselC. F. RoosR. BlattM. Abgrall +3 M. Chwalla
J. Benhelm

K. Kim
G. Kirchmair
T. Monz
M. Riebe
P. Schindler
A. S. Villar
W. Haensel
C. F. Roos
R. Blatt
M. Abgrall
+15
The authors report the first absolute frequency measurement of the $^{40}\mathrm{Ca}^{+}$ $S_{1/2}$–$D_{5/2}$ clock transition at the $10^{-15}$ fractional uncertainty level. Using a single laser-cooled ion in a linear Paul trap and a frequency comb referenced to a transportable Cs fountain clock, they obtain $f_{\mathrm{Ca}^{+}} = 411\,042\,129\,776\,393.2\,(1.0)\,\mathrm{Hz}$ after systematic corrections. The measurement also yields the Landé $g$-factor $g_{D_{5/2}} = 1.2003340(3)$.

arXiv ·
· June 9, 2008