MCP
MT

M. E. Tobar

48 papers in the library

Papers

30
Dynamically tuneable helicity in twisted electromagnetic resonators
E. C. I. PatersonJ. BourhillM. E. TobarM. Goryachev
This paper reports dynamically tunable electromagnetic helicity in a microwave cavity resonator, achieved by introducing chirality through a controlled geometric twist of the conducting boundary. The helicity arises from magnetoelectric coupling between nearly degenerate TE and TM modes, quantified by the nonzero spatial overlap $\mathrm{Im}[\vec{\mathbf{E}}_i(\vec{r})\cdot\vec{\mathbf{H}}_i^*(\vec{r})]$, not seen in conventional cavities. Varying the twist angle $\phi$ enables real-time manipulation of both helicity and resonant frequency, with additional surface chirality from internal helical corrugations contributing to asymmetric tuning.
arXivarXiv · · September 19, 2025
0
Distinct Berry Phases in a Single Triangular Möbius Microwave Resonator
E. C. I. PatersonM. E. TobarM. GoryachevJ. Bourhill
This paper reports the experimental observation of two distinct Berry phases, $+2\pi/3$ and $-2\pi/3$, on the surface of a triangular Möbius microwave resonator. The resonator, a twisted prism with $D_3$ symmetry bent into a ring, supports microwave modes with nonzero electromagnetic helicity. Modes lacking three-fold rotational symmetry accumulate a Berry phase, detectable through frequency shifts relative to a mirror-symmetric resonator, while symmetric modes do not.
arXivarXiv · · May 26, 2025
0
Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX
ADMX CollaborationG. Carosi…M. E. Tobar
The Axion Dark Matter eXperiment (ADMX) searches for axion dark matter using a haloscope that converts axions to photons in a magnetic field, enhanced by a microwave resonator. In its most recent run, ADMX searched for axions in the frequency range 1.10–1.31 GHz, extending the sensitivity to the Kim-Shifman-Vainshtein-Zakharov (KSVZ) axion model, with the setup cooled by a dilution refrigerator and near quantum-limited amplifiers to reduce noise. This Letter presents the results of this run and the unique aspects of the experimental configuration.
arXivarXiv · · April 9, 2025
0
75
Electromagnetic Helicity in Twisted Cavity Resonators
E. C. I. PatersonJ. BourhillM. E. TobarM. Goryachev
This paper shows that twisting a triangular-cross-section cavity resonator induces chirality in its conducting boundaries, which couples near-degenerate TE$_{11(p+1)}$ and TM$_{11p}$ modes to produce eigenmodes with non-zero electromagnetic helicity. This magneto-electric coupling is equivalent to introducing an effective chirality parameter $\kappa_\text{eff}$ or axion field $\theta_\text{eff}$ into the medium and causes a measurable frequency shift with twist angle, enabling real-time macroscopic manipulation of helicity.
arXivarXiv · · April 4, 2025
0
Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 μμeV
M. GuzzettiD. Zhang…M. E. Tobar
This paper derives a theoretical noise model for the axion haloscope receiver chain, using ADMX as a case study. The model accounts for noise sources from the cavity and amplifiers, including a previously unidentified cavity-JPA interaction. Calibration measurements at 1280 MHz from ADMX's recent run validate the model and improve systematic uncertainty on the system noise temperature for axion searches in the 4.54–5.41 $\mu$eV range, also guiding future noise reduction.
arXivarXiv · · November 11, 2024
0
0
Upconversion of Phonon Modes into Microwave Photons in a Lithium Niobate Bulk Acoustic Wave Resonator Coupled to a Microwave Cavity
S. ParasharW. M. CampbellJ. BourhillE. N. IvanovM. GoryachevM. E. Tobar
The authors couple acoustic vibrations in a lithium niobate bulk acoustic wave resonator to microwave photons in a re-entrant cavity at 4 K. By placing the acoustic resonator at the cavity's electric field maxima in a symmetric split-post configuration, they achieve large overlap and acoustic modulation of the microwave frequency. The acoustic modes retain quality factors exceeding $10^6$, and the measured optomechanical coupling rate $g_0 = 0.014$ mHz is four orders of magnitude larger than previous quartz-based results in a similar setup.
arXivarXiv · · October 26, 2024
0
Search for non-virialized axions with 3.3-4.2 μμeV mass at selected resolving powers
A. T. HippA. Quiskamp…M. E. Tobar
The Axion Dark Matter eXperiment sets constraints on non-virialized axion dark matter flows, which are characterized by low velocity dispersion. Excluding local densities above $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ for DFSZ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for KSVZ axion-photon couplings, the search covers the mass range $3.3-4.2\,\mu\text{eV}$ at selected resolving powers to account for different possible velocity spreads.
arXivarXiv · · October 11, 2024
0
4
Axion Dark Matter eXperiment around 3.3 μeV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability
C. GoodmanM. Guzzetti…M. E. Tobar
This paper reports a QCD axion dark matter search using an axion haloscope that reaches sub-Kelvin noise temperatures via a Josephson parametric amplifier in a dilution refrigerator. The experiment excludes (at 90% confidence) DFSZ axions with masses between 3.27 and 3.34 μeV, assuming a standard halo model with a local dark matter density of 0.45 GeV/cm³ composed entirely of axions.
arXivarXiv · · August 27, 2024
0
12
Rigorous ESR spectroscopy of Fe3+Fe^{3+} impurity ion with oxygen vacancy in ferroelectric SrTiO3SrTiO_3 crystal at 20 mK
M. A. HosainJ-M. Le FlochJ. KrupkaM. E. Tobar
By performing ESR spectroscopy on Fe³⁺ impurities in SrTiO₃ at 20 mK using multiple dielectric modes and a tunable DC magnetic field up to 1.6 T, the authors report a giant g-factor of $g_{\parallel F} = 5.51$ for the Fe³⁺-oxygen-vacancy complex $(Fe^{3+}-V_O)$ in the ferroelectric phase. The observed g-factor is attributed to the change in Fe³⁺ center-symmetry within the FeO₆ octahedron, linked to the soft-mode characteristics of the ferroelectric phase transition and the asymmetry in the octahedral rotational parameter $\Phi$.
arXivarXiv · · March 24, 2024
0
Aggregate Frequency Width, Nuclear Hyperfine Coupling and Jahn-Teller Effect of Cu2+Cu^{2+} Impurity Ion ESR in SrLaAlO4SrLaAlO_4 Dielectric Resonator at 2020 Millikelvin
M. A. HosainJ.-M. Le FlochJ. KrupkaM. E. Tobar
In $SrLaAlO_4$ single crystal at 20 millikelvin, substituting $Al^{3+}$ with $Cu^{2+}$ creates an elongated $CuO_6$ octahedron whose ESR aggregate frequency width is evaluated for the minimum impurity level. Parallel hyperfine constants $A_{\parallel Cu}$ are measured at four nuclear magnetic quantum numbers, revealing anisotropy characteristic of a static Jahn-Teller effect. The second-order anisotropy term $\sim (\text{spin-orbit coupling}/10D_q)^2$ is significant because local strain dominates the Zeeman-anisotropy-energy difference. The Bohr magneton $\beta=9.23\times10^{-24}\text{JT}^{-1}$ is derived from spin-Hamiltonian parameters within $-0.43\%$ experimental error.
arXivarXiv · · March 24, 2024
0
Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo
C. BartramT. Braine…M. E. Tobar
The Axion Dark Matter eXperiment (ADMX) reports the most sensitive search for non-virialized axions, sensitive to Doppler effects in the Milky Way halo. Over the mass range 2.81–3.31 μeV (680–800 MHz) and accounting for frequency shifts from the detector's motion, the analysis excludes cold flow relic axions with a velocity dispersion of order $10^{-7} c$ at 95% confidence.
arXivarXiv · · November 13, 2023
0
Search for a dark-matter induced Cosmic Axion Background with ADMX
ADMX CollaborationT.Nitta…M. E. Tobar
The Axion Dark Matter eXperiment (ADMX) reports the first direct search for a Cosmic Axion Background (C$a$B), a relativistic axion background distinct from dark matter. A novel analysis strategy searches for a daily modulation in the haloscope's power, induced by the C$a$B. Using data originally collected for dark matter, a limit is set on the axion-photon coupling from a C$a$B produced by dark matter cascade decay via a mediator, in the 800-995 MHz range. Current sensitivity is limited by readout fluctuations, but superconducting qubits could enable single-photon detection, allowing ADMX to operate as an axion telescope.
arXivarXiv · · March 11, 2023
0
39
Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes
S. ChakrabartyJ.R. Gleason…M.E. Tobar
This paper investigates reentrant and dielectric loaded cavities to extend axion cavity haloscope searches below the mass range already covered by ADMX. Through numerical simulations and a prototype reentrant cavity experiment, the authors calculate and optimize form factors and quality factors. They estimate the sensitivity of such cavities in the existing ADMX magnet and a larger magnet at Fermilab, enabling low-frequency (100-600 MHz) axion dark matter searches.
arXivarXiv · · March 7, 2023
0
18
Searching for Scalar Field Dark Matter using Cavity Resonators and Capacitors
V.V. FlambaumB.T. McAllisterI.B. SamsonovM.E. Tobar
This paper proposes experiments to search for scalar field dark matter with a dilaton-like coupling to the electromagnetic field, motivated by superstring theory. By re-purposing existing cavity resonators such as ADMX, new limits on the scalar-photon coupling are set for scalar field masses of 2.7–4.2 $\mu$eV. The authors also propose a broadband experiment using a high-voltage capacitor, whose estimated sensitivity exceeds that of molecular spectroscopy experiments by nearly two orders of magnitude.
arXivarXiv · · July 29, 2022
0
New Horizons: Scalar and Vector Ultralight Dark Matter
D. AntypasA. Banerjee…M. E. Tobar
This white paper focuses on searches for wavelike scalar and vector ultralight dark matter candidates, with mass below $10\,\mathrm{eV}$, which can be described as an oscillating classical, largely coherent field. It reviews the recent transformative advances in quantum technologies that have enabled a new generation of high-precision quantum sensors and detection strategies targeting such bosonic dark matter.
arXivarXiv · · March 28, 2022
0
209
Axion Dark Matter
C. B. AdamsN. Aggarwal…M. E. Tobar
This white paper reviews axion dark matter, a well-motivated candidate originally proposed to solve the strong CP problem and arising in many Standard Model extensions. It outlines next-generation laboratory experiments—using quantum-enabled readout, high-Q resonators, and large high-field magnets—to detect axions, emphasizing synergies with astrophysical searches and a US-led roadmap to discovery in the coming decade.
arXivarXiv · · March 28, 2022
0
368
Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier
C. BartramT. Braine…M. E. Tobar
This paper reports the first dark matter axion search using a Josephson Traveling Wave Parametric Amplifier (JTWPA). The JTWPA was integrated into the ADMX receiver chain attached to a 0.588-liter cavity. The search established a new exclusion bound for axion-photon couplings above $10^{-13}$ GeV$^{-1}$ over 4796.7--4799.5 MHz, corresponding to axion masses around 19.84 $\mu$eV. The JTWPA's high gain over a 3 GHz bandwidth makes it a promising technology for broadband axion searches.
arXivarXiv · · October 15, 2021
0
133
Search for "Invisible" Axion Dark Matter in the 3.3-4.2 μ3.3\text{-}4.2~μeV Mass Range
ADMX CollaborationC. Bartram…M. E. Tobar
This paper reports a haloscope search for axion dark matter in the $3.3\text{-}4.2~\mu$eV mass range. By combining a large-volume cavity, a superconducting magnet, a Josephson parametric amplifier, and sub-Kelvin temperatures, the search achieves sensitivity sufficient to exclude the axion-photon coupling predicted by the KSVZ model, a benchmark 'invisible' axion scenario. The detection procedure is validated by blind injection of synthetic axion signals.
arXivarXiv · · October 12, 2021
0
Axion Dark Matter eXperiment: Run 1B Analysis Details
ADMX CollaborationC. Bartram…M. E. Tobar
The ADMX collaboration reports the exclusion of DFSZ axions as 100% of the dark matter in the mass range 2.81–3.31 μeV (680–790 MHz) using data from January to October 2018 (Run 1B). This paper details the analysis for that run, including the rationale behind analysis choices shaped by run-specific conditions such as mode crossings.
arXivarXiv · · October 13, 2020
0
110
Piezo-optomechanical coupling of a 3D microwave resonator to a bulk acoustic wave crystalline resonator
N. C. CarvalhoJ. BourhillM. GoryachevS. GalliouM. E. Tobar
The paper reports coupling between a 3D microwave cavity mode and a bulk mechanical resonator via piezoelectric and radiation pressure effects. A quartz bulk acoustic wave resonator is placed inside a microwave re-entrant cavity that serves as both electrodes and a 3D resonator. The cavity mode is modulated by a 5 MHz shear acoustic wave, modeled and verified with input-output formalism. Finite-element simulations quantify electromechanical coupling contributions, and the system's potential for high cooperativities is discussed.
arXivarXiv · · July 2019
0
Testing of Generalized Uncertainty Principle With Macroscopic Mechanical Oscillators and Pendulums
P. A. BushevJ. BourhillM. GoryachevN. KukharchykE. IvanovS. GalliouM. E. TobarS. Danilishin
This paper tests the generalized uncertainty principle, a quantum gravity signature, by detecting the amplitude-frequency effect in macroscopic mechanical oscillators. Using a 0.3 kg sapphire resonator, the authors set an upper limit on the correction constant $\beta_0 < 5 \times 10^6$, six times better than previous bounds. A quartz resonator yields a stricter limit of $4 \times 10^4$. Historical pendulum data suggest $\beta_0 \ll 1$ but cannot provide a reliable bound, and pendulums only test a specific commutator form, whereas electro-mechanical oscillators allow testing any form.
arXivarXiv · · March 8, 2019
0
Ferroelectric phase transition and crystal asymmetry monitoring of SrTiO3SrTiO_3 using quasi TEm,1,1TE_{m,1,1} and quasi TMm,1,1TM_{m,1,1} modes
M. A. HosainJ-M. Le FlochJ. F. BourhillJ. KrupkaM. E. Tobar
Using quasi $TE_{m,1,1}$ and quasi $TM_{m,1,1}$ microwave modes, the authors probe dielectric properties of $SrTiO_3$ single crystal in continuous cooling. Crystal asymmetry is validated via a quasiharmonic phonon approximation. The ferroelectric phase transition occurs near 51 K, with quantum paraelectric stabilization below 5 K. An extra loss term, explained by Landau’s correlation-length theory, allows identification of the transition by a discontinuity in the derivative of the temperature characteristic near the minimum of total cavity loss. This is confirmed by transmission amplitude variation under a 200 V dc field, supporting a soft-mode model with imaginary frequency.
arXivarXiv · · April 17, 2018
0
Sensitivity Characterisation of a Parametric Transducer for Gravitational Wave Detection Through Optical Spring Effect
N. C. CarvalhoO. D. AguiarJ. BourhillM. E. Tobar
This paper characterizes a parametric microwave transducer for the Mario Schenberg gravitational wave detector. The transducer, a re-entrant cavity attached to a rigid spring, operates as a three-mode mass-spring system where the spherical antenna's motion couples to a thin membrane, shifting the cavity's resonance frequency. Using the optical spring effect, the frequency-displacement sensitivity reaches 726 MHz/μm at 4 K. The full antenna detection sensitivity is derived analytically from the measured transducer gain of 5.5 × 10^11 V/m and displacement noise of 1.8 × 10^-19 m/√Hz.
arXivarXiv · · March 7, 2017
0
3
Low-Temperature Microwave Properties of Biaxial YAlO3
N. C. CarvalhoM. GoryachevJ. KrupkaP. BushevM. E. Tobar
This work characterizes the microwave permittivity tensor of single-crystal YAlO₃ using the Whispering Gallery Mode Technique from room temperature to 20 mK, showing it is biaxial with uncertainties below 0.26%. At 20 mK, the authors identify two new electron spin resonance transitions with zero-field splittings of 16.72 and 9.92 GHz, and observe spin-photon couplings of 4.2 and 8.4 MHz for residual impurity levels, which exceed the cavity linewidths of 116 kHz but are comparable to the spin transition linewidths.
arXivarXiv · · February 8, 2017
0
Acoustic tests of Lorentz symmetry using Bulk Acoustic Wave quartz oscillators
M. GoryachevA. LoPh. HaslingerE. MizrachiL. AndereggH. MüllerM. HohenseeM.E. Tobar
This paper introduces a new method to test Lorentz invariance in the neutron sector using stable quartz bulk acoustic wave oscillators placed on a rotating table. Lorentz-violating effects would cause the resonance frequencies of these oscillators to depend on spatial direction through changes in the constituent masses. The experiment measures this dependence via oscillator phase noise, yielding a constraint on the neutron-sector coefficient $\tilde{c}^n_Q = (-1.8 \pm 2.2) \times 10^{-14}$ GeV. Improvements and other fundamental-physics applications are discussed.
arXivarXiv · · July 25, 2016
0
1
Towards achieving strong coupling in 3D-cavity with solid state spin resonance
J-M. Le FlochN. DelhoteM. AubourgV. MadrangeasD. CrosS. CastellettoM.E. Tobar
The paper designs a 3D microwave cavity to achieve strong coupling between cavity photons and solid-state spins. Using finite-element analysis, the authors propose a cavity design that yields a magnetic filling factor up to four times larger than 1D superconducting cavities, thereby doubling the collective coupling for an ensemble of nitrogen vacancy defects in diamond. A double-split resonator design further improves the cooperative factor by up to 200 times over currently demonstrated NV-diamond systems. These designs enable strong and ultra-strong coupling studies with broader design flexibility.
arXivarXiv · · April 6, 2016
0
Quartz-superconductor quantum electromechanical system
M. J. WoolleyM. F. EmzirG. J. MilburnM. JergerM. GoryachevM. E. TobarA. Fedorov
This paper proposes and analyzes a quantum electromechanical system where a monolithic quartz BAW oscillator is coupled to a superconducting transmon qubit via an intermediate LC circuit. The central contribution is showing that ground-state cooling of the high-mass quartz oscillator is feasible, achieved by resonant piezoelectric coupling to the LC circuit, which is itself sideband cooled via the qubit. The qubit's fluorescence spectrum, which includes motional sidebands, simultaneously serves as a readout of the electromechanical steady state, making the qubit both a cooling resource and a transducer for the mechanical oscillator.
arXivarXiv · · April 6, 2016
0
15
Piezoelectric Tunable Microwave Superconducting Cavity
N. C. CarvalhoY. FanM. E. Tobar
This paper presents a 3D microwave reentrant cavity whose resonant frequency is finely tuned by a mechanically amplified piezoelectric actuator that changes the narrow gap of the cavity. At dilution refrigerator temperatures, the device achieves a tuning range of 1 GHz while maintaining a high Q-factor at few-photon power levels, as demonstrated by experiments and FEM simulations. Nonlinear thermal effects from high microwave power can destroy superconductivity.
arXivarXiv · · March 15, 2016
0
Multi-mode technique for the determination of the biaxial Y2SiO5 permittivity tensor from 300 to 6 Kelvin
N. C. CarvalhoJ-M. Le FlochJ. KrupkaM. E. Tobar
This paper reports the first microwave characterization of the real permittivity tensor of the biaxial Y2SiO5 (YSO) crystal, measured from 296 K down to 6 K with uncertainties below 0.26%. The authors developed a multi-mode technique that simultaneously uses low-order Whispering Gallery Modes to determine the tensor components. The temperature dependence of the permittivity tensor is provided, along with electrical Q-factors that indicate crystal losses. This data is essential for designing technologies such as microwave coupling to RE-doped samples at low temperatures.
arXivarXiv · · March 12, 2015
0
Addressing a single NV−^{-} spin with a macroscopic dielectric microwave cavity
J.-M. Le FlochC. BradacN. NandS. CastellettoM.E. TobarT. Volz
This work demonstrates optically detected magnetic resonance (ODMR) for a single NV$^{-}$ center in a nanodiamond (ND) using a tunable macroscopic dielectric microwave cavity located directly above the ND. By moving the cavity relative to the ND, the authors map the cavity magnetic field distribution along one axis. They also argue the system can straightforwardly determine the orientation of the NV$^{-}$ major axis.
arXivarXiv · · December 29, 2014
0
0
Frequent collaborators
M. Goryachev (24)
G. Carosi (12)
N. Du (12)
G. Rybka (12)
D. B. Tanner (12)
R. Khatiwada (12)
C. Boutan (12)
C. Bartram (12)
A. Sonnenschein (11)
S. Knirck (11)
E. Lentz (11)
John Clarke (10)