MCP
MP

M. Pecora

10 papers in the library

Papers

10
The LAUE project and its main results
E. VirgilliF. Frontera…M. Pecora
The LAUE project, supported by the Italian Space Agency, demonstrates the feasibility of a focusing Laue lens for the 80–600 keV hard X-ray/soft gamma-ray band. A petal prototype with 20 m focal length is being assembled at the new LARIX facility. The project has already shown that a petal-based Laue lens is feasible, establishing a path toward future spaceborne focusing optics.
arXivarXiv · · January 20, 2014
0
31
Scientific prospects in soft gamma-ray astronomy enabled by the LAUE project
F. FronteraE. VirgilliV. ValsanV. LiccardoV. CarassitiE. CaroliF. CasseseC. FerrariV. GuidiS. MottiniM. PecoraB. Negri  +15
The LAUE project, supported by the Italian Space Agency, develops long focal length (up to 100 m) Laue lenses for soft gamma-ray astronomy (80-600 keV). Its key advance is the use of bent crystals. Based on single-crystal measurements and simulations, a lens assembled from petals is expected to achieve a sensitivity of a few $\times10^{-8}$ photons cm$^{-2}$ s$^{-1}$ keV$^{-1}$, enabling the study of several open astrophysical questions from a satellite platform.
arXivarXiv · · October 2, 2013
0
24
Development status of the LAUE project
F. FronteraE. Virgilli…M. Pecora
The LAUE project, supported by the Italian Space Agency, develops Laue lenses with a focal length of up to 100 meters for hard X-ray/soft gamma-ray astronomy (80–600 keV). The central contribution is its design goal to improve sensitivity by two orders of magnitude over current instrumentation, down to a few times $10^{-8}$ photons/(cm$^2$ s keV), through focusing capability.
arXivarXiv · · November 21, 2012
0
11
The LAUE project for broadband gamma-ray focusing lenses
E. VirgilliF. FronteraV. ValsanV. LiccardoE. CaroliJ.B. StephenF. CasseseL. RecanatesiM. PecoraS. MottiniP. AttináB. Negri
The LAUE project aims to develop a high focal length Laue lens for soft gamma-ray astronomy in the 80–600 keV band. The central contribution is a focusing optics technology that can improve current sensitivity in this energy band by two orders of magnitude.
arXivarXiv · · October 25, 2011
0
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
F. VillaL. Terenzi…M. Pecora
This paper reports the pre-launch calibration of the eleven radiometer subsystems (RCAs) aboard the Planck Low Frequency Instrument. Each RCA, a pseudo-correlation receiver, was tested in a cryogenic environment with its front-end at 20 K and back-end at 300 K, using a variable-temperature blackbody load. Key parameters—noise temperature, gain, 1/f noise, spectral response, and thermal susceptibility—were measured. These results provide essential inputs for Planck-LFI data analysis.
arXivarXiv · · May 14, 2010
0
28
Planck LFI flight model feed horns
F. VillaO. D'ArcangeloM. PecoraL. FiginiR. NestiA. SimonettoC. SozziM. SandriP. BattagliaP. GuzziM. BersanelliR.C. Butler  +1
This paper describes the design, manufacturing, and testing of the 11 corrugated feed horns that optically interface the Planck Low Frequency Instrument (LFI) with the ESA Planck telescope. The horns were designed to optimize the LFI optical interfaces while satisfying the stringent mechanical requirements of the Planck focal plane layout. All eleven flight-model units were successfully tested and integrated with the Ortho Mode Transducers.
arXivarXiv · · January 26, 2010
0
The PLANCK LFI flight model ortho-mode transducers
O. D'ArcangeloA. SimonettoL. FiginiE. PaganaF.VillaM. PecoraP. BattagliaM. BersanelliR.C. ButlerS. GaravagliaP. GuzziN. Mandolesi  +1
The Planck LFI uses 22 ultra-sensitive pseudocorrelation radiometers at 30, 44, and 70 GHz to measure CMB anisotropy and polarization. Intrinsic polarization sensitivity is achieved by Ortho-Mode Transducers (OMTs) that separate incoming radiation into two linear orthogonal components. A set of 11 flight-model OMTs (2 at 30 GHz, 3 at 44 GHz, 6 at 70 GHz) was developed through an Elegant Bread Board and Qualification Model campaign. The paper reports that all flight units were accepted and their electromagnetic performance is at least marginally compliant with requirements, with mechanical qualification passed after a rework.
arXivarXiv · · January 26, 2010
0
16
The Planck-LFI flight model composite waveguides
O. D'ArcangeloL. FiginiA. SimonettoF.VillaM. PecoraP. BattagliaM. BersanelliR.C. ButlerF. CuttaiaS. GaravagliaP. GuzziN. Mandolesi  +4
The Planck-LFI composite waveguides (WGs) connect the 20 K Front End Modules to the 300 K Back End Modules. A stainless-steel/copper composite design was selected to satisfy conflicting thermal, electromagnetic, and mechanical requirements: minimizing heat load while limiting signal attenuation. The WGs, 1.5–2 m long, were manufactured and tested. Their measured performance meets the requirements, and they were successfully space qualified.
arXivarXiv · · January 26, 2010
0
12
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
A. MennellaM. Bersanelli…M. Pecora
Based on ground cryogenic tests, the Planck Low Frequency Instrument (LFI) achieves excellent $1/f$ stability and rejection of systematic effects, with measured noise performance making it the most sensitive instrument of its kind. These calibration parameters represent the best pre-launch characterization of the LFI's scientific performance and will be updated during flight operations.
arXivarXiv · · January 25, 2010
0
55
Planck pre-launch status: Design and description of the Low Frequency Instrument
M. BersanelliN. Mandolesi…M. Pecora
This paper describes the design and scientific requirements of the Planck Low Frequency Instrument (LFI), a 20-K cryogenic array of differential microwave radiometers using Indium Phosphide HEMT amplifiers and 4-K blackbody reference loads. LFI will map the full sky in intensity and polarization at 30, 44, and 70 GHz to complement the higher-frequency HFI instrument in precision imaging of the cosmic microwave background.
arXivarXiv · · January 19, 2010
0
308
Frequent collaborators
P. Battaglia (6)
M. Bersanelli (6)
O. D'Arcangelo (6)
N. Mandolesi (6)
A. Simonetto (6)
C. Sozzi (5)
E. Virgilli (4)
F. Frontera (4)
V. Valsan (4)
V. Liccardo (4)
E. Caroli (4)
F. Cassese (4)