Real-world sleep phenotyping in autism: compliance, domain shift, and scalable wearable biomarkers
SVSanketh VedulaAndrew KimManoj KumarOlga TroyanskayaGuillermo Sapiro
SVSanketh Vedula
Andrew Kim
Manoj Kumar
Olga Troyanskaya
Guillermo Sapiro
+5
In the Simons Sleep Project, 200 children with autism were recorded over 14 nights using dry-electrode EEG headbands and wrist sensors (PPG, IMU, temperature). Headband compliance declined systematically overnight and correlated with behavioral measures, producing structured missingness that biases sleep estimates, whereas wrist sensors retained near-complete adherence. Sleep-staging models trained on clinical-grade data transferred poorly to wearables, but this domain shift proved learnable with limited supervision: fine-tuning the SleepFM foundation model on 102 participants achieved a macro F1 of 0.780, and supervised PPG models reached 0.710 versus 0.375 out-of-the-box for PaPaGei. PPG emerged as the most informative standalone peripheral signal, with PPG+IMU capturing most wrist-based staging information, while frontal–occipital EEG derivations outperformed prefrontal channels. The authors conclude that wrist-worn PPG+IMU offers a scalable backbone for longitudinal ambulatory sleep phenotyping, with EEG remaining valuable for micro-architectural analysis when tolerated.

PMLR · September 8, 2026