Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
R.Y. ShopaK. Klimaszewski…N. Krawczyk
We optimise the event-based TOF filtered back-projection (FBP) for online imaging in total-body J-PET. Using Monte Carlo simulations of phantoms, we show that an asymmetric 3D filtering kernel applied at each most likely annihilation position, combined with high-pass filters, yields 1.5× better axial spatial resolution than conventional 3D FBP. For realistic scans requiring noise–resolution trade-off, Gaussian TOF kernels and median post-filtering are needed. The best 3D filter parameter sets are obtained via Nelder–Mead minimisation of the mean squared error, enabling training for custom scans when temporal resolution is below 50 ps.
arXivarXiv · · July 27, 2021
0
23
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
P. MoskalT. Bednarski…N. Krawczyk
The J-PET 24-module prototype, a plastic-scintillator-strip scanner with a 300 mm axial field of view, demonstrates a cost-effective approach to total-body PET. Its triggerless DAQ and digital front-end required novel calibration for time, thresholds, and gain. The prototype achieves a coincidence resolving time of CRT = $490 \pm 9$ ps, yielding a position reconstruction accuracy of $\sigma(\Delta l) = 18$ mm that is largely position-independent.
arXivarXiv · · August 25, 2020
0
20
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
N. G. SharmaM. Silarski…N. Krawczyk
The paper presents a new signal-processing method for reconstructing hit-position and hit-time in long plastic scintillator detectors, motivated by J-PET scanners. The method uses the Mahalanobis distance to measure the similarity between registered signals and synchronized model signals stored in a library. Validated on a two-strip J-PET prototype (5×9×300 mm³), the method yields Time-of-Flight (TOF) resolution of 325 ps FWHM and spatial resolution of 25 mm FWHM. Compared to the simpler Linear Fitting method, the Mahalanobis approach achieves comparable TOF resolution with fewer threshold levels, reducing electronics cost.
arXivarXiv · · April 27, 2020
0
0
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
S. SharmaJ. Chhokar…N. Krawczyk
The authors establish a relationship between Time-Over-Threshold (TOT) and energy loss for photons in the plastic scintillators of the J-PET scanner, using a $^{22}$Na source placed at the scanner centre. The source emits 511 keV and 1275 keV photons, and by measuring the scattering angle from the J-PET geometry, the incident photon energy and deposited energy are determined unambiguously. The resulting TOT-energy calibration covers the 100–1000 keV range, enabling TOT to replace charge integration for combined time and energy readout in the J-PET tomograph.
arXivarXiv · · November 27, 2019
0
67
Performance assessment of the 2γγ positronium imaging with the total-body PET scanners
P. MoskalD. Kisielewska…N. Krawczyk
This paper assesses the feasibility of reconstructing ortho-positronium lifetime images from 2γ annihilations in total-body PET scanners. Simulations using $^{44}$Sc (a positron and prompt gamma emitter) and triple coincidences show that total-body sensitivity for lifetime imaging is 12.2 times (LYSO) and 4.7 times (plastic) higher than standard 2γ imaging with a 20 cm AFOV LYSO scanner. Spatial and time resolution are evaluated for coincidence resolving times of 140 ps, 50 ps, and 10 ps.
arXivarXiv · · November 15, 2019
0
89
Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
N. KrawczykB. C. HiesmayrC. CurceanuE. CzerwińskiK. DulskiA. GajosM. GorgolN. Gupta-SharmaB. JasińskaK. KacprzakŁ. KapłonD. Kisielewska  +22
The J-PET tomograph, built from plastic scintillators, detects 511 keV photons from electron-positron annihilation. Compton scattering, most probable at an angle orthogonal to the photon's electric field, allows polarization determination by registering multiple scatterings. This study estimates the physical limitations on the accuracy of such polarization measurements for J-PET.
arXivarXiv · · January 18, 2019
0
1
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
P. MoskalN. KrawczykB. C. HiesmayrM. BałaC. CurceanuE. CzerwińskiK. DulskiA. GajosM. GorgolR. Del GrandeB. JasińskaK. Kacprzak  +22
The J-PET detector, which registers 511 keV photons via Compton scattering in plastic scintillators, can determine the linear polarization of individual photons on an event-by-event basis. For a scattering angle of about 82°, the single-event polarization resolution is approximately 40°, but for samples exceeding ten thousand events, the relative average polarization can be determined to within a few degrees. This extends polarization measurements to the MeV energy range, five orders of magnitude beyond the optical regime, enabling studies of quantum entanglement and discrete symmetries in positronium decays.
arXivarXiv · · September 27, 2018
0
82
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
K. DulskiC. Curceanu…N. Krawczyk
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET detector built from plastic scintillators and is designed for both medical imaging and studies of positronium properties. This paper reports the commissioning of J-PET for positronium decay studies. By analyzing positron lifetime in a porous polymer, the authors demonstrate that J-PET can simultaneously image the density distribution of annihilation points and perform positron annihilation lifetime spectroscopy.
arXivarXiv · · September 12, 2018
0
32
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
J. RajA. Gajos…N. Krawczyk
This work assesses the feasibility of testing time reversal (T) violation using polarized annihilation photons from ortho-positronium decay with the J-PET detector. J-PET, an organic-scintillator scanner with axial symmetry and high acceptance, can measure both momenta and polarization vectors of annihilation photons. The unique polarization measurement enables construction of a T-violation operator from photon momenta before and after scattering in the detector, making J-PET suitable for this discrete-symmetry test beyond medical imaging.
arXivarXiv · · September 4, 2018
0
9
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
G. KorcylP. Białas…N. Krawczyk
This paper proposes and evaluates a single-chip FPGA-SoC platform for real-time tomographic data processing using the J-PET scanner. The system directly connects to scanner data streams, performing event building, filtering, coincidence search, and region-of-response reconstruction in programmable logic, with visualization on integrated processors. It significantly reduces data volume by converting raw data to list-mode representation while generating on-the-fly visualization, eliminating the need for powerful local computing facilities.
arXivarXiv · · July 26, 2018
0
130
Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner
R. MasełekW. Krzemien…N. Krawczyk
The authors propose an energy-based method to separate 511 keV annihilation photons from prompt de-excitation photons in the J-PET scanner for 2+1 photon tomography. By setting an energy deposited threshold, signals below the threshold are identified as 511 keV photons and those above as prompt photons. Analyzing several radioisotopes, they select $^{44}\mathrm{Sc}$ as the most promising candidate. Simulations with GATE and J-POS yield an optimal threshold of about 375 keV, achieving nearly 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.
arXivarXiv · · March 2, 2018
0
5
Human Tissues Investigation Using PALS Technique
B. JasińskaB. Zgardzińska…N. Krawczyk
This study applies Positron Annihilation Lifetime Spectroscopy (PALS) to uterine leiomyoma and normal tissue from patients. Significant differences in all PALS parameters were observed between the two tissue types. Tumorous tissues showed longer free annihilation and ortho-positronium lifetimes than healthy tissues. For most patients, the intensities of these annihilation channels were lower in tumors. The paper's novel contribution is the first determination of the $3\gamma$ annihilation fraction in such studies, used to characterize changes in tissue porosity during morphological alteration.
arXivarXiv · · November 13, 2017
0
66
J-PET: a new technology for the whole-body PET imaging
S. NiedźwieckiP. Białas…N. Krawczyk
J-PET is the first whole-body PET scanner built from plastic scintillators instead of conventional crystals. Its 192 detection modules are arranged axially in three layers, forming a 85-cm diameter cylindrical chamber with a 50-cm axial field of view. The long strips of plastic scintillators provide low light attenuation, superior timing, and easy scalability of the axial field of view, offering a cost-effective path to whole-body PET imaging and compatibility with MR and CT inserts.
arXivarXiv · · October 31, 2017
0
211
Introduction of total variation regularization into filtered backprojection algorithm
L. RaczyńskiW. Wiślicki…N. Krawczyk
This paper extends the filtered backprojection (FBP) algorithm by introducing total variation (TV) regularization, replacing the common use of apodizing functions. The proposed method is validated on a Derenzo-type phantom and yields higher cross-correlation coefficients between the reconstructed and true radioactive tracer distribution compared to standard FBP, demonstrating improved reconstruction quality.
arXivarXiv · · October 31, 2017
0
1
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
R. Y. ShopaK. Klimaszewski…N. Krawczyk
The paper presents a 3D image reconstruction method for the J-PET tomograph using Filtered Back Projection, implemented in the STIR and TomoPy packages. Simulated 511 keV annihilation photons from a 1 mm spherical source were detected by a cylindrical detector, with hit coordinates smeared to match experimental resolutions. Without time-of-flight information, consistent Point Spread Functions of approximately 5-7 mm transverse and 9-20 mm longitudinal were obtained using STIR.
arXivarXiv · · October 30, 2017
0
8
Commissioning of the J-PET detector for studies of decays of positronium atoms
E. CzerwińskiK. Dulski…N. Krawczyk
The Jagiellonian PET (J-PET) detector, designed for whole-body medical imaging and physics studies of electron-positron annihilation, is shown to reject background in positronium decays due to its high angular and time resolution. This capability enables measurement of the positronium spin and the momenta and polarization vectors of annihilation quanta, extending the detector's utility beyond imaging into fundamental physics research.
arXivarXiv · · October 30, 2017
0
16
Time calibration of the J-PET detector
M. SkurzokM. Silarski…N. Krawczyk
This paper presents the time calibration and synchronization of the J-PET scanner, a PET prototype for whole-body 3D imaging using organic scintillators. Each of the 192 scintillator strips arranged in three cylindrical layers is irradiated with a $^{22}\text{Na}$ source. A small detector provides a common reference time, enabling synchronization of all detector modules for high time- and angular-resolution imaging of annihilation photons.
arXivarXiv · · October 16, 2017
0
6
Analysis procedure of the positronium lifetime spectra for the J-PET detector
K. DulskiB. Zgardzinska…N. Krawczyk
The authors present a computer program for analyzing positronium lifetime spectra from the J-PET detector, which combines positron emission tomography with positron annihilation lifetime spectroscopy. The program uses an iterative fitting procedure and, when tested on hexane data at various temperatures, performs comparably to the standard LT 9.0 software.
arXivarXiv · · October 16, 2017
0
16
Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
L. RaczyńskiW. Wiślicki…N. Krawczyk
The paper derives closed-form analytical formulas for the time resolution of the J-PET tomograph by combining Tikhonov regularization for signal processing with Kernel Density Estimation. The method is validated on signals from a single 30 cm plastic scintillator detection unit with vacuum tube photomultipliers, showing consistency between experimental and theoretical results.
arXivarXiv · · June 3, 2017
0
Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
J. SmyrskiD. Alfs…N. Krawczyk
This paper demonstrates that the axial coordinate of a gamma quantum interaction point inside a plastic scintillator bar can be measured by detecting scintillation photons escaping the bar with an array of wavelength-shifting (WLS) strips. Using a BC-420 scintillator bar and sixteen BC-482A WLS strips, a spatial resolution of 5 mm ($\sigma$) was achieved for annihilation photons from $^{22}$Na, suggesting a potential improvement for the J-PET collaboration's plastic-scintillator-based PET scanner.
arXivarXiv · · December 27, 2016
0
61
A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
D. KamińskaA. Gajos…N. Krawczyk
This paper demonstrates that the J-PET scanner, constructed from plastic scintillators rather than the inorganic crystals used in standard PET scanners, can measure angular and energy resolutions of $\sigma(\theta) \approx 0.4^{\circ}$ and $\sigma(E) \approx 4.1$ keV for ortho-positronium $3\gamma$ decays. While Compton scattering in plastic prevents direct energy measurement, the faster signal decay in plastic reduces pileup, allowing higher source activity to compensate for lower efficiency. Monte Carlo simulations confirm J-PET's suitability for studying discrete symmetries in o-Ps decays alongside medical imaging.
arXivarXiv · · July 28, 2016
0
113
Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system
P. MoskalD. Alfs…N. Krawczyk
The Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector capable of testing discrete symmetries in the purely leptonic positronium system. Positronium—a parity and charge conjugation eigenstate—decays into photons. J-PET can determine expectation values of discrete-symmetries-odd operators constructed from the ortho-positronium spin and the momenta and polarization vectors of its annihilation photons, enabling tests of C, CP, T, and CPT symmetries in the leptonic sector.
arXivarXiv · · February 16, 2016
0
125