MCP
OD

O. D'Arcangelo

23 papers in the library

Papers

23
Fast dynamics of radiofrequency emission in plasmas with runaway electrons
P. BurattiW. BinA. CardinaliD. CarnevaleC. CastaldoO. D'ArcangeloF. NapoliG.L. RaveraA. SelceL. PanaccioneA. RomanoFTU Team
Radiofrequency emission in the 0.4–3 GHz range from FTU plasmas with runaway electrons (RE) was measured with high time resolution. Rapid emission bursts, linked to enhanced RE pitch-angle scattering, reveal kinetic instabilities affecting the RE population from its buildup phase. The leading edge of bursts is much shorter than inter-burst intervals, and spectral broadening during growth suggests nonlinear wave coupling causes the observed intermittency. Emission disappears during post-disruption RE plateaus, then reappears as intense bursts with strong suprathermal electron cyclotron emission rises.
arXivarXiv · · December 20, 2020
0
Planck Intermediate Results. IX. Detection of the Galactic haze with Planck
Planck CollaborationP. A. R. Ade…O. D'Arcangelo
Using Planck full-sky observations and component separation methods, the Galactic haze is identified as a distinct diffuse microwave emission component centered on the Galactic center, extending to |b|~35° and |l|~15°. Combining Planck with WMAP data determines its spectrum with high accuracy, excluding systematic biases. The spectrum follows a power law with index -2.55±0.05, consistent with hard-spectrum synchrotron radiation from electrons with dN/dE~E^{-2.1}, ruling out free-free emission. The haze's morphology matches the Fermi gamma-ray bubbles at |b|<30°, providing a multi-wavelength view. Its hard spectrum and extended nature imply a new cosmic-ray acceleration mechanism at the Galactic center rather than supernova shocks in the disk.
arXivarXiv · · August 27, 2012
0
612
Planck Early Results XXVI: Detection with Planck and confirmation by XMM-Newton of PLCK G266.6-27.3, an exceptionally X-ray luminous and massive galaxy cluster at z~1
Planck CollaborationN. Aghanim…O. D&#39;Arcangelo
PLCK G266.6-27.3, a galaxy cluster candidate detected at signal-to-noise 5 in the Planck All Sky survey, is confirmed as a bona fide cluster by XMM-Newton. At redshift $z=0.94\pm0.02$, it has mass $M_{500}=(7.8\pm0.8)\times10^{14}$ solar masses and X-ray luminosity $L_X(0.5\!-\!2.0\,\text{keV})=(1.4\pm0.05)\times10^{45}$ erg/s, matching the two most luminous known clusters at $z>0.5$ and ranking among the most massive at $z\sim1$, while being unusually relaxed—a demonstration of Planck's ability to detect extreme high-redshift clusters.
arXivarXiv · · June 7, 2011
0
130
Planck Early Results: The Planck mission
Planck CollaborationP. A. R. Ade…O. D&#39;Arcangelo
The Planck satellite, launched by ESA on 14 May 2009, has been surveying the sky continuously since 13 August 2009 with performance meeting expectations. This paper provides an overview of Planck's first year of operations and key satellite performance aspects, as part of a package accompanying the Early Release Compact Source Catalogue—the first public Planck data product.
arXivarXiv · · January 11, 2011
0
1k+
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
A. MennellaM. Bersanelli…O. D&#39;Arcangelo
This paper assesses the in-flight performance of Planck's Low Frequency Instrument (LFI) after one year of operation. It presents the main optical parameters, photometric calibration, white noise sensitivity, and noise properties, along with a preliminary evaluation of systematic effects. The methods used to derive these parameters from flight data are outlined, and the results confirm pre-launch ground assessments.
arXivarXiv · · January 11, 2011
0
234
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
F. VillaL. Terenzi…O. D&#39;Arcangelo
This paper reports the pre-launch calibration of the eleven radiometer subsystems (RCAs) aboard the Planck Low Frequency Instrument. Each RCA, a pseudo-correlation receiver, was tested in a cryogenic environment with its front-end at 20 K and back-end at 300 K, using a variable-temperature blackbody load. Key parameters—noise temperature, gain, 1/f noise, spectral response, and thermal susceptibility—were measured. These results provide essential inputs for Planck-LFI data analysis.
arXivarXiv · · May 14, 2010
0
28
A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline
M. FrailisM. Maris…O. D&#39;Arcangelo
This paper presents the end-to-end validation tests performed on the Level 1 pipeline of the Planck LFI Data Processing Centre (DPC). The key contribution is a systematic verification procedure that treats on-board and ground processing as a single pipeline. Scientific data was validated by injecting known signals into the acquisition electronics to generate real telemetry, while housekeeping data was tested by injecting known parameter values into packets and comparing the resulting timelines. The procedure demonstrated that the pipeline correctly meets project requirements.
arXivarXiv · · January 27, 2010
0
7
Planck-LFI radiometers' spectral response
A ZoncaC FranceschetP BattagliaF VillaA MennellaO D&#39;ArcangeloR SilvestriM BersanelliE ArtalR C ButlerF CuttaiaR J Davis  +13
This paper reports the measured broadband spectral response of all Planck-LFI radiometers (30, 44, 70 GHz bands). The band shapes were obtained by combining per-component laboratory measurements through a dedicated RF model of the receiver, rather than direct end-to-end tests, which yielded only qualitative results due to setup systematic effects. The measured bandpasses show moderate ripple consistent with scientific requirements.
arXivarXiv · · January 26, 2010
0
55
Noise Properties of the Planck-LFI Receivers
P. MeinholdR. LeonardiB. AjaE. ArtalP. BattagliaM. BersanelliE. BlackhurstC. R. ButlerL. P. CuevasF. CuttaiaO. D&#39;ArcangeloR. Davis  +38
This paper characterizes the noise properties of the Planck Low Frequency Instrument (LFI) radiometers using extensive test campaigns. It reports the primary noise parameters, establishing the baseline performance of these receivers for the Planck mission. The work provides a foundation for understanding the instrument's sensitivity and systematic effects.
arXivarXiv · · January 26, 2010
0
42
The linearity response of the Planck-LFI flight model receivers
A. MennellaF. VillaL. TerenziF. CuttaiaP. BattagliaM. BersanelliR.C. ButlerO. D&#39;ArcangeloE. ArtalR. DavisM. FrailisC. Franceschet  +28
This paper characterizes the linearity response of the Planck-LFI receivers, focusing on signal compression in the 30 and 44 GHz channels. The authors present a model that accurately describes test data from radiometric chains, then provide a best-fit parameter set for the receiver response. They conclude that the impact of this nonlinearity on in-flight calibration is negligible.
arXivarXiv · · January 26, 2010
0
15
Planck LFI flight model feed horns
F. VillaO. D&#39;ArcangeloM. PecoraL. FiginiR. NestiA. SimonettoC. SozziM. SandriP. BattagliaP. GuzziM. BersanelliR.C. Butler  +1
This paper describes the design, manufacturing, and testing of the 11 corrugated feed horns that optically interface the Planck Low Frequency Instrument (LFI) with the ESA Planck telescope. The horns were designed to optimize the LFI optical interfaces while satisfying the stringent mechanical requirements of the Planck focal plane layout. All eleven flight-model units were successfully tested and integrated with the Ortho Mode Transducers.
arXivarXiv · · January 26, 2010
0
Off-line radiometric analysis of Planck/LFI data
M. TomasiA. Mennella…O. D&#39;Arcangelo
This paper describes the LIFE software suite developed for off-line radiometric analysis of Planck/LFI data. LIFE provides a common platform for calibrating and verifying the LFI's 22 pseudo-correlation radiometers using both ground test and flight data. Its key feature is a multi-layered, cross-platform architecture with analysis modules in IDL and an optimized C/C++ library, enabling consistent analysis across pre-launch and in-flight phases. The suite was successfully validated during instrument tests and operations verification.
arXivarXiv · · January 26, 2010
0
9
Thermal susceptibility of the Planck-LFI receivers
L TerenziM J SalmonA ColinA MennellaG MorganteM TomasiP BattagliaM LapollaM BersanelliR C ButlerF CuttaiaO D&#39;Arcangelo  +24
This paper analyzes how physical temperature fluctuations in the Planck Low Frequency Instrument's front end affect the output signal. The authors identify the origins of these thermal instabilities and develop an analytical model of their propagation and impact on the receiver signal. They describe the experimental test setup used during ground calibration and the data analysis methods employed. The main results are compared against the instrument's requirements, providing a quantitative assessment of thermal susceptibility.
arXivarXiv · · January 26, 2010
0
11
Advanced modelling of the Planck-LFI radiometers
P. BattagliaC. FranceschetA .ZoncaM. BersanelliR. C. ButlerO. D&#39;ArcangeloR. J. DavisS. GaleottaP. GuzziR. HoylandN. HughesP. Jukkala  +13
The paper presents the LFI Advanced RF Model (LARFM), a software model of the Planck-LFI pseudo-correlation receivers developed to reproduce and predict the main system parameters of the 44 detectors, including total gain, noise temperature, band-pass, and non-linear response. The model was built from commercial tools and unit-level component measurements, validated against ground-test data, and is used in the LFI data processing center for studying radiometer behaviour.
arXivarXiv · · January 26, 2010
0
6
The PLANCK LFI flight model ortho-mode transducers
O. D&#39;ArcangeloA. SimonettoL. FiginiE. PaganaF.VillaM. PecoraP. BattagliaM. BersanelliR.C. ButlerS. GaravagliaP. GuzziN. Mandolesi  +1
The Planck LFI uses 22 ultra-sensitive pseudocorrelation radiometers at 30, 44, and 70 GHz to measure CMB anisotropy and polarization. Intrinsic polarization sensitivity is achieved by Ortho-Mode Transducers (OMTs) that separate incoming radiation into two linear orthogonal components. A set of 11 flight-model OMTs (2 at 30 GHz, 3 at 44 GHz, 6 at 70 GHz) was developed through an Elegant Bread Board and Qualification Model campaign. The paper reports that all flight units were accepted and their electromagnetic performance is at least marginally compliant with requirements, with mechanical qualification passed after a rework.
arXivarXiv · · January 26, 2010
0
16
The Planck-LFI flight model composite waveguides
O. D&#39;ArcangeloL. FiginiA. SimonettoF.VillaM. PecoraP. BattagliaM. BersanelliR.C. ButlerF. CuttaiaS. GaravagliaP. GuzziN. Mandolesi  +4
The Planck-LFI composite waveguides (WGs) connect the 20 K Front End Modules to the 300 K Back End Modules. A stainless-steel/copper composite design was selected to satisfy conflicting thermal, electromagnetic, and mechanical requirements: minimizing heat load while limiting signal attenuation. The WGs, 1.5–2 m long, were manufactured and tested. Their measured performance meets the requirements, and they were successfully space qualified.
arXivarXiv · · January 26, 2010
0
12
Level 1 on-ground telemetry handling in Planck LFI
A. ZaccheiM. Frailis…O. D&#39;Arcangelo
This paper describes the Level 1 on-ground telemetry handling system for the Planck Low Frequency Instrument (LFI), which observes the Cosmic Microwave Background at 30-70 GHz. The system processes LFI telemetry packets (containing scientific data from 22 radiometers and housekeeping data) and produces timelines for each acquisition chain and housekeeping parameter. These timelines serve as input to higher processing levels. The system includes a real-time monitoring component based on SCOS 2000, a telemetry handler, and a quick-look visualization tool. It is designed to support all mission phases from ground tests to flight operations, following ESA engineering standards.
arXivarXiv · · January 26, 2010
0
7
Optimization of Planck/LFI on--board data handling
M.MarisM.Tomasi…O.D&#39;Arcangelo
The Planck/LFI onboard data-handling pipeline compresses raw detector data to fit a 35.5 kbps telemetry bandwidth. A lossy process parameterized by five values per detector is optimized by an automated tool (OCA2) that minimizes distortion $\epsilon_Q$ while achieving a compression ratio $C_r=2.4$. An analytical model relating $\epsilon_Q$ and $C_r$ to signal statistics and processing parameters supports the optimization. During ground tests representative of flight, the optimized parameters yielded $\epsilon_Q=3.8\%$ of white noise rms, meeting the $\leq10\%$ requirement.
arXivarXiv · · January 26, 2010
0
15
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
R.J. DavisA. Wilkinson…O. D&#39;Arcangelo
The paper describes the design, construction, and testing of the 30 and 44 GHz front-end modules (FEMs) for the Planck Low Frequency Instrument. Each FEM is a differential pseudo-correlation radiometer comparing sky signal with a 4-K blackbody load, using an indium phosphide HEMT-based low-noise amplifier and a novel phase-switch. The FEMs meet or exceed all mission requirements, including noise temperature, stability, and linear polarization. The most sensitive amplifiers achieve noise temperatures of 3 and 5 times the quantum limit at 30 and 44 GHz band centres, respectively, setting new noise-temperature benchmarks for HEMTs.
arXivarXiv · · January 26, 2010
0
32
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
M. MalaspinaE. FranceschiP. BattagliaP. BinkoR.C. ButlerO. D&#39;ArcangeloS. FoglianiM. FrailisC. FranceschetS. GaleottaF. GasparoA. Gregorio  +17
This paper presents Rachel, a software application developed for testing Planck's Low Frequency Instrument radiometer chain assemblies (RCAs) before full array integration. Rachel provides near-realtime on-line data analysis and stores raw radiometric chain outputs in FITS format during the RCA test campaign, supporting the characterization of each pseudo-correlation radiometer.
arXivarXiv · · January 26, 2010
0
4
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
A. MennellaM. BersanelliR. C. ButlerF. CuttaiaO. D&#39;ArcangeloR. J. DavisM. FrailisS. GaleottaA. GregorioC. R. LawrenceR. LeonardiS. R. Lowe  +74
Based on ground cryogenic tests, the Planck Low Frequency Instrument (LFI) achieves excellent $1/f$ stability and rejection of systematic effects, with measured noise performance making it the most sensitive instrument of its kind. These calibration parameters represent the best pre-launch characterization of the LFI's scientific performance and will be updated during flight operations.
arXivarXiv · · January 25, 2010
0
55
Planck pre-launch status: Design and description of the Low Frequency Instrument
M. BersanelliN. Mandolesi…O. D&#39;Arcangelo
This paper describes the design and scientific requirements of the Planck Low Frequency Instrument (LFI), a 20-K cryogenic array of differential microwave radiometers using Indium Phosphide HEMT amplifiers and 4-K blackbody reference loads. LFI will map the full sky in intensity and polarization at 30, 44, and 70 GHz to complement the higher-frequency HFI instrument in precision imaging of the cosmic microwave background.
arXivarXiv · · January 19, 2010
0
308
Planck pre-launch status: the Planck-LFI programme
N. MandolesiM. Bersanelli…O. D&#39;Arcangelo
The Planck Low Frequency Instrument (LFI) programme is designed to produce high-precision maps of the microwave sky at 27–77 GHz, targeting the cosmic microwave background (CMB) and foregrounds. The instrument has been developed and tested, with a data processing centre (DPC) capable of reducing flight data into calibrated time-ordered data, sky maps (temperature and polarization), component emission maps, and source catalogues. Tests on the flight model demonstrate excellent performance, and the pipeline's main steps are verified. After launch, three months of commissioning and calibration will precede the operational phase.
arXivarXiv · · January 15, 2010
0
186
Frequent collaborators
N. Mandolesi (19)
M. Bersanelli (16)
R. Leonardi (15)
A. Mennella (15)
M. Sandri (15)
M. Tomasi (15)
A. Zonca (15)
F. Cuttaia (14)
S. Galeotta (14)
A. Gregorio (14)
L. Terenzi (14)
A. Zacchei (14)