MCP
OP

O. Preis

6 papers in the library

Papers

6
The Nice Cube (Nice3) nanosatellite project
F. MillourS. Ottogalli…O. Preis
CubeSats have limited data-transmission capability. The Nice Cube (Nice3) project at Universite Cote d'Azur studies the feasibility of a student-built CubeSat that uses an optical link to the ground to achieve a moderate downlink rate of 1 kb/s or better. This paper reports the current state of the project and its planned future developments.
arXivarXiv · · August 29, 2018
0
1
A detector interferometric calibration experiment for high precision astrometry
A. CrouzierF. MalbetF. HenaultA. LegerC. CaraJ. M. LeDuigouO. PreisP. KernA. DelboulbeG. MartinP. FeautrierE. Stadler  +14
This paper presents an experimental calibration method for high-precision astrometry using a detector interferometric testbed. The method generates modulated Young fringes on the detector, parameterized by time- and space-dependent pixel functions, and iteratively minimizes the parameters to extract pixel positions. The calibration achieves pixel position accuracy of 4e-4 pixel, leading to an astrometric accuracy of 6e-5 pixel for a point spread function (PSF) motion over five pixels, and a photon-noise-limited precision of 3e-5 pixel in static mode. The goal is to reach 5e-6 pixel accuracy for Nyquist-sampled polychromatic PSFs, enabling detection of habitable-zone low-mass planets around solar-like stars.
arXivarXiv · · September 8, 2016
0
The latest results from DICE (Detector Interferometric Calibration Experiment)
A. CrouzierF. MalbetF. HenaultA. LegerC. CaraJ. M. LeDuigouO. PreisP. KernA. DelboulbeG. MartinP. FeautrierE. Stadler  +14
The DICE testbed aims to achieve $10^{-5}$ pixel centroid precision for the Theia astrometric mission. After upgrades, its metrology system calibrated pixel positions to $4\times10^{-4}$ pixel accuracy. Using this calibration, a moving point-spread function (over $>5$ pixels) yielded an astrometric accuracy of $6\times10^{-5}$ pixel, while static jitter ($<10^{-3}$ pixel) reached a photon-noise-limited precision of $3\times10^{-5}$ pixel.
arXivarXiv · · August 1, 2016
0
Metrology calibration and very high accuracy centroiding with the NEAT testbed
A. CrouzierF. MalbetO. PreisF. HenaultP. KernG. MartinP. FeautrierE. StadlerS. LafrasseA. DelboulbeE. BeharM. Saint-Pe  +10
The NEAT astrometric mission requires centroiding precision of $5\times 10^{-6}$ pixel. The European consortium's testbed, operating in vacuum, combines a pseudo-star source (blackbody through a pinhole mask imaged onto a CCD) with a Young-fringe metrology system projected onto the same CCD. This metrology calibrates intra- and inter-pixel quantum efficiency variations, reducing pixelation errors. The paper reports experiments and data reduction since first light in July 2013, aiming to prove the feasibility of the required precision.
arXivarXiv · · July 5, 2014
0
First experimental results of very high accuracy centroiding measurements for the neat astrometric mission
A. CrouzierF. MalbetO. PreisF. HenaultP. KernG. MartinP. FeautrierE. StadlerS. LafrasseA. DelboulbeE. BeharM. Saint-Pe  +10
The NEAT astrometric mission requires centroiding precision of 5e-6 pixel to detect Earth-like exoplanets. The European NEAT consortium is building a vacuum testbed to demonstrate this precision. This paper presents the metrology and pseudo-stellar source subsystems, a performance model, and an error budget. First light was achieved in July 2013, and initial measurements taken in air already show pixel position accuracy of about 1e-4 pixel, representing a step toward the target precision.
arXivarXiv · · September 13, 2013
0
An experimental testbed for NEAT to demonstrate micro-pixel accuracy
A. CrouzierF. MalbetO. PreisF. HenaultP. KernG. MartinP. Feautrierc. CaraP. LagageA. LegerJ. M. LeDuigouM. Shao  +1
This paper describes the design of a vacuum testbed for the proposed NEAT astrometric mission, which must estimate stellar centroids at a precision of $5\times10^{-6}$ pixel. The testbed is intended to demonstrate that this precision is achievable once intra- and inter-pixel quantum efficiency variations are calibrated and corrected by a metrology system, a factor that simulations indicate is critical to reaching the required micro-pixel accuracy. The paper presents the basic relations, trade-offs, and design choices involved, along with the current status of the demonstration.
arXivarXiv · · August 1, 2012
0
Frequent collaborators
A. Crouzier (5)
F. Malbet (5)
F. Henault (5)
J. M. LeDuigou (5)
P. Kern (5)
G. Martin (5)
P. Feautrier (5)
M. Shao (5)
R. Goullioud (5)
A. Leger (4)
C. Cara (4)
A. Delboulbe (4)