MCP
PB

P. Barrow

24 papers in the library

Papers

24
A Precision Experiment to Investigate Long-Lived Radioactive Decays
J. R. AngevaareP. BarrowL. BaudisP. A. BreurA. BrownA. P. ColijnG. CoxM. GienalF. GjaltemaA. Helmling-CornellM. JonesA. Kish  +9
This paper introduces a dedicated experiment designed to investigate claims of non-Poissonian variations in long-lived radioactive decays. The setup monitors gamma emissions from $\beta$ decays using thirty-two NaI(Tl) detectors across four temperature-controlled sites on three continents. Environmental and operational conditions are tracked for correlation studies, and deadtime-free data acquisition is verified by LED pulsers. The experiment's stability and control of systematics enable precise measurements of effects well below $\mathcal{O}(10^{-4})$.
arXivarXiv · · April 8, 2018
0
Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
E. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. BenabderrahmaneT. Berger  +107
This paper reports liquid xenon response to keV electronic recoils from tritium beta decays below 15 keV, using the XENON100 detector at drift fields of 92, 154, and 366 V/cm. A Markov Chain Monte Carlo fitting method extracts photon yields and recombination fluctuations. At the two lower fields, yields agree with literature; the 366 V/cm measurement is new. The study also investigates electronic-nuclear recoil discrimination and its field dependence at these low energies, providing relevant data for dark matter searches. Key results include the first measurement at 366 V/cm and discrimination characterization.
arXivarXiv · · September 28, 2017
0
54
Search for Bosonic Super-WIMP Interactions with the XENON100 Experiment
XENON collaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiL. AlthueserF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. Bauermeister  +109
The XENON100 experiment searched for bosonic super-WIMPs, keV-scale dark matter candidates, using a dual-phase xenon time projection chamber. A profile likelihood analysis of 224.6 live days × 34 kg of data found no signal. This yielded the most stringent upper limits to date in the (8–125) keV/c² mass range, excluding couplings to electrons with $g_{ae} > 3 \times 10^{-13}$ for pseudo-scalar and $\alpha'/\alpha > 2 \times 10^{-28}$ for vector super-WIMPs, assuming they constitute all galactic dark matter.
arXivarXiv · · September 7, 2017
0
41
The XENON1T Dark Matter Experiment
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyB. AntunesF. ArneodoM. BalataP. BarrowL. Baudis  +133
The XENON1T experiment, located at LNGS, is the first ton-scale liquid xenon detector for WIMP dark matter. It uses a 2.0t active target from a 3.2t xenon inventory in a dual-phase time projection chamber, detecting scintillation and ionization signals with low-background photomultipliers. The paper describes the instrument, subsystems, and background-reduction strategies, and presents first results on detector response and subsystem performance.
arXivarXiv · · August 23, 2017
0
631
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +106
This paper describes how the XENON100 collaboration assessed intrinsic backgrounds from $^{222}$Rn, $^{220}$Rn, and $^{85}$Kr in their detector. Using high-energy alpha events and delayed coincidences, they derived the spatial distribution and abundance of each radionuclide across three science runs from 2010 to 2014. The results match external radon emanation and krypton measurements. A reduction in radon-daughter concentrations is attributed to the plating-out of charged ions on the negatively biased cathode.
arXivarXiv · · August 11, 2017
0
36
First Dark Matter Search Results from the XENON1T Experiment
E. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. BenabderrahmaneT. Berger  +113
The XENON1T experiment, a dual-phase xenon time projection chamber with approximately 2000 kg target mass, reports first dark matter search results from 34.2 live days of data. The electronic recoil background in the fiducial mass and WIMP search energy range is $(1.93 \pm 0.25) \times 10^{-4}$ events/(kg·day·keV$_{\mathrm{ee}}$), the lowest ever achieved in a dark matter detector. The data is consistent with the background-only hypothesis, yielding the most stringent exclusion limits on spin-independent WIMP-nucleon interaction cross sections for WIMP masses above 10 GeV/c$^2$, with a minimum of $7.7 \times 10^{-47}$ cm$^2$ at 90% confidence level for 35-GeV/c$^2$ WIMPs.
arXivarXiv · · May 18, 2017
0
1k+
Effective field theory search for high-energy nuclear recoils using the XENON100 dark matter detector
E. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. BenabderrahmaneT. Berger  +105
This paper reanalyzes XENON100 data from science run II (34 kg × 224.6 live days) using a non-relativistic effective field theory (EFT) for WIMP-nucleon interactions. Extending the nuclear recoil energy range to 6.6–240 keV_nr, the data remains compatible with background. The study sets 90% CL exclusion limits on EFT coupling constants via a binned profile likelihood, and also constrains inelastic WIMP scattering where the WIMP up-scatters to a higher mass state.
arXivarXiv · · May 7, 2017
0
101
Material radioassay and selection for the XENON1T dark matter experiment
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +109
The XENON1T dark matter experiment requires extremely radiopure materials to reduce background events when searching for WIMP signals. This paper reports the results of an extensive radioassay campaign using gamma-ray spectroscopy and mass spectrometry on over one hundred material samples. The measured trace radioactive activities guided material selection and placement during detector construction and provided essential input for Monte-Carlo-based sensitivity estimates.
arXivarXiv · · May 4, 2017
0
17
Search for WIMP Inelastic Scattering off Xenon Nuclei with XENON100
E. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. BenabderrahmaneT. Berger  +104
Using 7.64×10³ kg·day of XENON100 data, the first constraints on the spin-dependent inelastic WIMP-nucleon cross section are reported. The search targets WIMP-¹²⁹Xe scattering that excites the nucleus, producing a nuclear recoil accompanied by a prompt de-excitation photon. No signal is found, and a profile likelihood analysis yields a 90% C.L. upper limit of 3.3×10⁻³⁸ cm² at 100 GeV/c², the strongest bound on this channel to date.
arXivarXiv · · May 1, 2017
0
47
Search for magnetic inelastic dark matter with XENON100
XENON collaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +103
The XENON100 experiment reports the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using 224.6 live days of data. This signature is predicted by magnetic inelastic dark matter, a model proposed to reconcile the DAMA/LIBRA modulation signal with null results from other experiments. No candidate events were found; the scenarios with WIMP masses of 58.0 GeV/c$^2$ and 122.7 GeV/c$^2$ are excluded at 3.3 $\sigma$ and 9.3 $\sigma$, respectively.
arXivarXiv · · April 19, 2017
0
16
Online 222^{222}Rn removal by cryogenic distillation in the XENON100 experiment
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +110
The XENON100 experiment uses a cryogenic distillation column integrated into its gas purification loop to remove radioactive $^{222}$Rn from xenon online. By inserting an auxiliary $^{222}$Rn emanation source, the column achieved a radon reduction factor of $R > 27$ (95% C.L.) in the detector, significantly reducing the constant radon background.
arXivarXiv · · February 22, 2017
0
Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data
XENON collaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +102
Using 4 years of XENON100 data (2010-2014), a profile likelihood method searched for periodic modulation of electronic recoil event rates. A weak modulation at $431^{+16}_{-14}$ days appeared in the $(2.0-5.8)$ keV single-scatter sample with $1.9\,\sigma$ global significance, but no other significant modulation was found. This annual modulation signature is incompatible with a dark matter signal, and it excludes the DAMA/LIBRA annual modulation due to dark matter electron interactions via axial vector coupling at $5.7\,\sigma$.
arXivarXiv · · January 3, 2017
0
102
Removing krypton from xenon by cryogenic distillation to the ppq level
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +110
The XENON1T dark matter experiment requires a natural krypton concentration in xenon below 200 ppq to suppress background from $^{85}$Kr beta decay. This work describes a cryogenic distillation column designed with the McCabe-Thiele method that achieves a krypton reduction factor of $6.4\cdot10^5$ at process speeds above 3 kg/h. The resulting $\rm{^{nat}}$Kr/Xe concentration below 26 ppq is the lowest ever reported, nearly an order of magnitude below the XENON1T requirement and sufficient for future experiments like XENONnT and DARWIN.
arXivarXiv · · December 13, 2016
0
134
Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF.D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM.L. Benabderrahmane  +109
The XENON100 dark matter detector was calibrated using a dissolved $^{220}$Rn source. The $^{212}$Pb beta emission provided a low-energy electronic recoil calibration for dark matter searches, with the isotope spreading throughout the active volume and its activity decaying below background within a week after source closure. The $^{220}$Rn/$^{216}$Po delayed coincidence enabled the first mapping of convective motion inside the detector. A competitive measurement of the $^{212}$Po half-life, $t = 293.9 \pm 1.0 \pm 0.6$ ns, was also obtained.
arXivarXiv · · November 11, 2016
0
121
XENON100 Dark Matter Results from a Combination of 477 Live Days
XENON100 CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +105
Combining three runs totaling 477 live days from January 2010 to January 2014, the XENON100 experiment sets a new limit on the spin-independent WIMP-nucleon scattering cross section. With an ultra-low background of ~$5 \times 10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) and an exposure of 48 kg$\times$yr, a profile likelihood analysis of the (6.6–43.3) keV$_{\mathrm{nr}}$ energy range yields a minimum cross section of $1.1 \times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and 90% confidence level for WIMP masses above 8 GeV/$c^2$. Updated spin-dependent constraints are also reported.
arXivarXiv · · September 20, 2016
0
270
Search for Two-Neutrino Double Electron Capture of 124^{124}Xe with XENON100
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +105
Using 7636 kg·d of XENON100 data, a Bayesian search found no significant excess above background for two-neutrino double electron capture from the K-shell of $^{124}$Xe, setting a lower 90% credibility limit on the half-life of $T_{1/2}>6.5\times10^{20}$ yr. The projected sensitivity of XENON1T, currently being commissioned, reaches $T_{1/2}>6.1\times10^{22}$ yr after 2 t·yr exposure.
arXivarXiv · · September 12, 2016
0
Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector
P. BarrowL. BaudisD. CichonM. DanischD. FrancoF. KaetherA. KishM. LindnerT. Marrodan UndagoitiaD. MayaniL. RauchY. Wei  +1
The paper reports qualification tests of 321 Hamamatsu R11410-21 photomultiplier tubes (PMTs) for the XENON1T dark matter detector, selecting 248 for installation. The low-radioactivity, high-quantum-efficiency PMTs were tested in a nitrogen atmosphere at cryogenic temperatures, and a subset in gaseous and liquid xenon to simulate operating conditions. The study presents parameter distributions for all tested tubes, details rejection criteria, and discusses the impact of the selected PMTs on detector performance.
arXivarXiv · · September 6, 2016
0
DARWIN: towards the ultimate dark matter detector
J. AalbersF. AgostiniM. AlfonsiF.D. AmaroC. AmslerE. AprileL. AraziF. ArneodoP. BarrowL. BaudisM.L. BenabderrahmaneT. Berger  +107
DARWIN is a proposed multi-ton liquid xenon time projection chamber for direct dark matter detection. Its primary goal is to explore the accessible WIMP parameter space until neutrino interactions become an irreducible background. Besides WIMPs above 5 GeV/c², the detector's large mass, low threshold, and ultra-low background enable searches for solar axions, neutrinoless double-beta decay of ¹³⁶Xe, and coherent neutrino-nucleus scattering, as well as precision measurements of low-energy solar neutrinos.
arXivarXiv · · June 22, 2016
0
1k+
A low-mass dark matter search using ionization signals in XENON100
XENON100 CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiF. D. AmaroM. AnthonyF. ArneodoP. BarrowL. BaudisB. BauermeisterM. L. Benabderrahmane  +99
The XENON100 detector reports a dark matter search that uses only the ionization signal, dropping the scintillation requirement to lower the nuclear-recoil energy threshold to 0.7~keV. With 30 kg×yr of exposure, no background model can be constructed, so every selected event is treated as a potential signal. From 0.7 to 9.1~keV, an upper limit on the spin-independent WIMP-nucleon cross section excludes 6 GeV/$c^2$ WIMPs above $1.4\times10^{-41}$ cm$^2$ at 90% confidence.
arXivarXiv · · May 20, 2016
0
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
XENON CollaborationE. AprileF. AgostiniM. AlfonsiL. AraziK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. Bauermeister  +89
Using XENON100 electronic recoil data, the search finds no evidence of dark matter interacting with electrons, excluding several leptophilic models. For axial-vector couplings, cross-sections above $6 \times 10^{-35} \,\text{cm}^2$ are ruled out for a particle mass of $m_\chi = 2 \,\text{GeV}/c^2$. Halo-independently, DAMA/LIBRA's signal is excluded as arising from axial-vector couplings (4.4$\sigma$), mirror dark matter (3.6$\sigma$), and luminous dark matter (4.6$\sigma$).
arXivarXiv · · July 28, 2015
0
101
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
XENON CollaborationE. AprileJ. AalbersF. AgostiniM. AlfonsiM. AnthonyL. AraziK. ArisakaF. ArneodoC. BalanP. BarrowL. Baudis  +90
An analysis of 224.6 live days of XENON100 electronic recoil data (2–6 keV, Feb 2011–Mar 2012) searched for periodic rate modulations up to 500 days. A profile likelihood study found no statistically significant modulation, with a global significance below 1σ. The local 2.8σ annual modulation signal is disfavored as a dark matter signature by a multiple-scatter control sample and the modulation phase, and the DAMA/LIBRA annual modulation interpreted via axial-vector WIMP–electron coupling is excluded at 4.8σ.
arXivarXiv · · July 28, 2015
0
79
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
E. AprileF. AgostiniM. AlfonsiL. AraziK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. BauermeisterA. Behrens  +86
By combining material screening and production modifications, the XENON collaboration and Hamamatsu reduced the radioactivity of the R11410-21 photomultiplier tube (PMT) for the XENON1T dark matter experiment. Measurements of individual PMT components with ultra-low background germanium detectors guided the selection of cleaner materials and assembly changes. A screening of 216 tubes confirmed a mean activity of $^{238}$U at 1.9 mBq/PMT and $^{232}$Th at 0.9 mBq/PMT, which is sufficiently low for the experiment's background goals.
arXivarXiv · · March 26, 2015
0
148
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
E. AprileF. AgostiniM. AlfonsiK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. BauermeisterA. BehrensP. Beltrame  +79
The XENON1T dark matter detector requires a two-order-of-magnitude background reduction relative to XENON100. A water Cherenkov muon veto, 10 m in height and diameter, with 8-inch photomultipliers and reflective foil, was designed and optimized via Monte Carlo simulations. The central contribution is the demonstration that this veto achieves >99.5% efficiency for muons and >70% for muon-induced secondary showers, making muon-induced neutron backgrounds negligible for XENON1T.
arXivarXiv · · June 9, 2014
0
150
First Axion Results from the XENON100 Experiment
XENON100 CollaborationE. AprileF. AgostiniM. AlfonsiK. ArisakaF. ArneodoM. AugerC. BalanP. BarrowL. BaudisB. BauermeisterA. Behrens  +78
The XENON100 experiment reports the first direct search for axions and axion-like-particles using the axio-electric effect in liquid xenon. With 224.6 live days and a 34 kg fiducial exposure, no signal was found. The strongest limit to date is set on the axion-electron coupling $g_{Ae}$: below $7.7 \times 10^{-12}$ (90% CL) for solar axions, and below $1 \times 10^{-12}$ (90% CL) for axion-like-particles constituting the entirety of galactic dark matter in the 1--40 keV/$c^2$ mass range. Under the DFSZ and KSVZ models, QCD axions heavier than 0.3 eV/$c^2$ and 80 eV/$c^2$ are excluded, respectively.
arXivarXiv · · April 5, 2014
0
226
Frequent collaborators
L. Baudis (24)
A. Kish (24)
A. Brown (23)
M. Schumann (23)
M. Lindner (23)
C. Reuter (22)
E. Aprile (22)
F. Agostini (22)
M. Alfonsi (22)
F. Arneodo (22)
G. Bruno (22)
R. Budnik (22)