MCP
PB

P. Benetti

17 papers in the library

Papers

17
Search for Inelastic Boosted Dark Matter with the ICARUS Detector at the Gran Sasso Underground National Laboratory
H. CarranzaJ. YuB. BrownS. BlanchardS. ChakrabortyR. RautD. KimM. AntonelloB. BaibussinovV. BelliniP. BenettiF. Boffelli  +48
Using 0.13 kton·year of ICARUS T-600 data, this search targets inelastic boosted dark matter (DM) from a multi-particle dark sector with a U(1)′ dark photon. The signal requires a DM particle inelastically scattering off an electron, producing a heavier dark state that decays to emit a dark photon, which kinetically mixes with a Standard Model photon and converts into an e⁺e⁻ pair. This yields a recoil electron plus an associated e⁺e⁻ pair. No events were observed among 4,134 triggers, leading to exclusion limits in the (m_X, ε) parameter space.
arXivarXiv · · December 12, 2024
0
Neutron emission from fracturing of granite blocks: An experimental revisitation
P. BenettiF. BoffelliC. MarcianoA. PiazzoliG.L. Raselli
This paper revisits the claim that neutron bursts are emitted during the fracture of Luserna granite. In controlled mechanical-loading experiments designed to replicate the earlier work of Carpinteri et al. (2013), no neutrons were detected. The authors therefore question the validity of those previously reported measurements.
arXivarXiv · · September 4, 2020
0
Double-beta decay investigation with highly pure enriched 82^{82}Se for the LUCIFER experiment
J.W. BeemanF. BelliniP. BenettiL. CardaniN. CasaliD. ChiesaM. ClemenzaI. DafineiS. Di DomizioF. FerroniL. GironiA. Giuliani  +17
The LUCIFER experiment aims to search for neutrinoless double-beta decay of $^{82}$Se using ZnSe scintillating bolometers. This study measured the radiopurity of 2.5 kg of 96.3% enriched $^{82}$Se metal at the Gran Sasso underground laboratory. Limits on contamination from $^{232}$Th, $^{238}$U, and $^{235}$U were set at <61, <110, and <74 μBq/kg (90% C.L.), respectively. These measurements enabled the most stringent lower limits on the half-lives of $^{82}$Se double-beta decay to the $0^+_1$, $2^+_2$, and $2^+_1$ excited states of $^{82}$Kr: $3.4\times10^{22}$ y, $1.3\times10^{22}$ y, and $1.0\times10^{22}$ y (90% C.L.).
arXivarXiv · · August 7, 2015
0
1
A Proposal for a Three Detector Short-Baseline Neutrino Oscillation Program in the Fermilab Booster Neutrino Beam
R. AcciarriC. Adams…P. Benetti
This proposal presents a Short-Baseline Neutrino (SBN) program using three Liquid Argon Time Projection Chamber (LAr-TPC) detectors along Fermilab's Booster Neutrino Beam to resolve neutrino anomalies and search for sterile neutrinos at the eV mass scale. With specific proton-on-target data sets, the program achieves ~5 sigma sensitivity for muon-to-electron neutrino appearance in the LSND-allowed parameter region, enabling both appearance and disappearance oscillation measurements. The document covers detector designs, infrastructure, and beamline reconfiguration options.
arXivarXiv · · March 5, 2015
0
427
Some conclusive considerations on the comparison of the ICARUS nu_mu to nu_e oscillation search with the MiniBooNE low-energy event excess
M. AntonelloB. BaibussinovP. BenettiF. BoffelliA. BubakE. CalligarichS. CentroA. CesanaK. CieslikD. B. ClineA.G. CoccoA. Dabrowska  +42
The ICARUS Collaboration searched for anomalous LSND-like $\nu_\mu \to \nu_e$ oscillations using their T600 LAr-TPC exposed to the CNGS beam. The result is consistent with no anomaly, setting oscillation probability limits of $3.4 \times 10^{-3}$ (90% CL) and $7.6 \times 10^{-3}$ (99% CL). These limits conflict with the low-energy event excess ($200 < E_{\nu}^{\text{QE}} < 475$ MeV) reported by MiniBooNE. After incorporating the official MiniBooNE energy resolution, the tension persists at 90% CL, implying the MiniBooNE excess may be unexplained or instrumental.
arXivarXiv · · February 17, 2015
0
Experimental observation of an extremely high electron lifetime with the ICARUS-T600 LAr-TPC
M. AntonelloB. BaibussinovP. BenettiF. BoffelliA. BubakE. CalligarichS. CentroA. CesanaK. CieslikD. B. ClineA.G. CoccoA. Dabrowska  +45
The ICARUS T600 detector, a large liquid Argon Time Projection Chamber (LAr-TPC) operated at the INFN Gran Sasso laboratory, achieved an electron lifetime exceeding 15 ms, corresponding to about 20 parts per trillion of equivalent O2 contamination. This milestone was enabled by the argon recirculation and purification systems, demonstrating that extremely low impurity levels necessary for long drift paths are attainable, a key result for scaling up future LAr-TPC detectors.
arXivarXiv · · September 19, 2014
0
The trigger system of the ICARUS experiment for the CNGS beam
M. AntonelloB. BaibussinovP. BenettiF. BoffelliA. BubakE. CalligarichS. CentroA. CesanaK. CieslikD. B. ClineA.G. CoccoA. Dabrowska  +47
The ICARUS T600 detector, the largest liquid Argon TPC ever built, uses a trigger system that combines scintillation light, charge signals on TPC wires, and time information (for beam events). The paper reports the system's efficiency, background, and live-time as functions of event energy, evaluated using thousands of CNGS neutrino interactions and cosmic ray events collected over three years.
arXivarXiv · · May 29, 2014
0
Search for anomalies in the νe appearance from a νμ beam
M. AntonelloB. BaibussinovP. BenettiF. BoffelliA. BubakE. CalligarichN. CanciS. CentroA. CesanaK. CieslikD. B. ClineA.G. Cocco  +48
Using an almost doubled sample of 1995 CNGS neutrino interactions, the ICARUS experiment identifies four clear νe events, against an expectation of 6.4±0.9 from conventional sources. The result is compatible with no anomalous νμ→νe oscillation. At 90% and 99% confidence levels, the limits on possible oscillated events are 3.7 and 8.3, corresponding to oscillation probability limits of 3.4×10^{-3} and 7.6×10^{-3}, respectively.
arXivarXiv · · July 17, 2013
0
Precise 3D track reconstruction algorithm for the ICARUS T600 liquid argon time projection chamber detector
M. AntonelloB. BaibussinovP. BenettiE. CalligarichN. CanciS. CentroA. CesanaK. CieslikD. B. ClineA. G. CoccoA. DabrowskaD. Dequal  +44
This paper presents a new 3D track reconstruction algorithm for liquid argon time projection chambers (LAr TPCs), implemented on the ICARUS T600 detector. The method reconstructs charged particle trajectories from the detector's spatial readout. Its efficiency is evaluated on simulated tracks, and the algorithm is also applied to real data tracks from the CNGS neutrino beam, demonstrating practical utility.
arXivarXiv · · October 18, 2012
0
Experimental search for the LSND anomaly with the ICARUS detector in the CNGS neutrino beam
M. AntonelloB. BaibussinovP. BenettiE. CalligarichN. CanciS. CentroA. CesanaK. CieslikD. B. ClineA. G. CoccoA. DabrowskaD. Dequal  +45
The ICARUS experiment searched for the LSND anomaly, which would appear as an excess of $\nu_e$ events from $\nu_\mu$ to $\nu_e$ oscillations with a fast energy oscillation averaging to $\sin^2(1.27\,\Delta m^2_{\text{new}}\,L/E_\nu)=1/2$. Using 1091 neutrino events (about 50% of its 2010-2011 CNGS data) at an average energy of 20 GeV over 730 km, ICARUS observed 2 $\nu_e$ events against 3.7±0.6 expected from conventional sources. This result is compatible with no anomaly and sets oscillation probability limits of $5.4\times10^{-3}$ (90% CL) and $1.1\times10^{-2}$ (99% CL), narrowing the allowed LSND parameter space to a small region around $(\Delta m^2,\, \sin^2(2\theta))_{\text{new}} = (0.5\,\text{eV}^2,\,0.005)$ where LSND, MiniBooNE, KARMEN, and ICARUS agree at 90% CL.
arXivarXiv · · September 1, 2012
0
Precision measurement of the neutrino velocity with the ICARUS detector in the CNGS beam
M. AntonelloB. BaibussinovF. BoffelliP. BenettiE. CalligarichN. CanciS. CentroA. CesanaK. CieslikD. B. ClineA. G. CoccoA. Dabrowska  +59
The ICARUS detector at LNGS measured the neutrino time of flight from CERN's CNGS beam using a 3-ns bunched proton beam. The measured neutrino arrival time is compatible with the speed of light, yielding a difference $\mathrm{tof}_c - \mathrm{tof}_\nu = (0.10 \pm 0.67_\mathrm{stat.} \pm 2.39_\mathrm{syst.})\,\mathrm{ns}$ for 25 events. This result improves upon the collaboration's earlier measurement with reduced statistical and systematic uncertainties.
arXivarXiv · · August 13, 2012
0
151
Measurement of the neutrino velocity with the ICARUS detector at the CNGS beam
M. AntonelloP. ApriliB. BaibussinovM. Baldo CeolinP. BenettiE. CalligarichN. CanciF. CarbonaraS. CentroA. CesanaK. CieslikD. B. Cline  +53
The ICARUS T600 detector at LNGS measured the time of flight of neutrinos from CERN using a specially bunched CNGS beam (four 3 ns bunches, 524 ns apart, with ~10^12 protons per pulse). From 7 beam-associated events, the neutrino arrival time was consistent with the speed of light, showing no evidence for superluminal propagation. This result directly contradicts the OPERA claim that neutrinos arrived ~60 ns earlier than light.
arXivarXiv · · March 15, 2012
0
A search for the analogue to Cherenkov radiation by high energy neutrinos at superluminal speeds in ICARUS
ICARUS CollaborationM. AntonelloP. ApriliB. BaibussinovM. Baldo CeolinP. BenettiE. CalligarichN. CanciF. CarbonaraS. CentroA. CesanaK. Cieslik  +53
The ICARUS experiment refutes the superluminal neutrino interpretation of the OPERA result by testing the Cohen–Glashow prediction that superluminal neutrinos ($\delta = 5 \times 10^{-5}$) would emit Cherenkov-like $e^+e^-$ pairs and photons via $Z^0$ exchange. Analyzing 2010–2011 data from the same CERN neutrino beam, ICARUS finds event rates and deposited energy distributions consistent with an unperturbed spectrum, with no such events observed. This yields a stricter limit of $\delta < 2.5 \times 10^{-8}$ at 90% confidence.
arXivarXiv · · October 17, 2011
0
54
Underground operation of the ICARUS T600 LAr-TPC: first results
C. RubbiaM. AntonelloP. ApriliB. BaibussinovM. Baldo CeolinL. BarzèP. BenettiE. CalligarichN. CanciF. CarbonaraF. CavannaS. Centro  +65
The ICARUS T600 Liquid Argon Time Projection Chamber (LAr-TPC) is the first large-mass (760 ton) detector combining bubble-chamber-like imaging with precise energy measurement. Operating at the Gran Sasso underground laboratory, it studies cosmic rays, neutrino oscillations, and proton decay. Its physical potential is demonstrated through neutrino interactions reconstructed with unprecedented detail, marking a new detector generation for fundamental physics.
arXivarXiv · · June 6, 2011
0
242
Effects of Nitrogen contamination in liquid Argon
R.AcciarriM.AntonelloB. BaibussinovM.Baldo-CeolinP.BenettiF.CalapriceE.CalligarichM.CambiaghiN.CanciF.CarbonaraF.CavannaS.Centro  +20
This paper measures the reduction of liquid argon scintillation light caused by nitrogen contamination. A dedicated detector injected controlled amounts of gaseous nitrogen into liquid argon, covering a concentration range from ~0.1 ppm to ~1000 ppm. Scintillation yield decreased with increasing nitrogen concentration, with a rate constant of $k(N_2)=0.11\,\mu\text{s}^{-1}\text{ppm}^{-1}$. The slow component's lifetime and amplitude decreased appreciably from O(1 ppm) concentration, observed via high-time-resolution PMT waveform recording.
arXivarXiv · · April 8, 2008
0
Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light
R.AcciarriM.AntonelloB.BaibussinovM.Baldo-CeolinP.BenettiF.CalapriceE.CalligarichM.CambiaghiN.CanciF.CarbonaraF.CavannaS. Centro  +21
The paper reports a combined measurement of oxygen contamination effects on both ionization electron charge and scintillation light in liquid argon (LAr), using two detectors at LNGS. The key result is the rate constant of the light quenching process induced by oxygen, $k'(O_2) = 0.54 \pm 0.03 \ \mu s^{-1} \text{ppm}^{-1}$, determined from the correlation between electron lifetime (inferring O$_2$ concentration) and the long-lived scintillation component lifetime over a concentration range of $10^{-3}$ to $10$ ppm. This provides a unified characterization of oxygen's impact on LAr detector performance.
arXivarXiv · · April 8, 2008
0
A new, very massive modular Liquid Argon Imaging Chamber to detect low energy off-axis neutrinos from the CNGS beam. (Project MODULAr)
B. BaibussinovM. Baldo CeolinG. BattistoniP. BenettiA. BorioE. CalligarichM. CambiaghiF. CavannaS. CentroA. G. CoccoR. DolfiniA. Gigli Berzolari  +24
The MODULAr proposal describes a 20 kt fiducial-volume liquid argon time projection chamber (LAr-TPC) for the CNGS beam, designed to detect low-energy off-axis neutrinos and to search for $\theta_{13}$ oscillations and CP violation. The detector, cloned from the ICARUS T600 technology, achieves higher efficiency and lower backgrounds than water Cherenkov or scintillator detectors by enabling unambiguous recognition of virtually all channels. The concept involves a modular array of five 5 kt units, a new 1.2 km water-equivalent depth experimental hall 10 km off-axis, and an upgraded proton beam, with an estimated 4-5 year construction timeline.
arXivarXiv · · April 11, 2007
0
Frequent collaborators
G. Meng (15)
B. Baibussinov (14)
S. Centro (14)
F. Pietropaolo (14)
S. Ventura (14)
E. Calligarich (13)
C. Farnese (13)
A. Fava (13)
A. Ferrari (13)
D. Gibin (13)
A. Guglielmi (13)
A. Menegolli (13)