MCP
PB

P. Bialas

86 papers in the library

Papers

30
Partition function zeros of zeta-urns
P. BialasZ. BurdaD. A. Johnston
This paper studies the partition function zeros of the grand-canonical zeta-urn model, which exhibits a condensation transition of arbitrary order controlled by a single parameter. The authors compute the locus of zeros for finite-size systems and test scaling relations for the accumulation of zeros near the critical point, comparing with theoretical predictions for both first and higher order transitions.
arXivarXiv · · December 4, 2023
0
2
Quantum partition of energy for a free Brownian particle: Impact of dissipation
J. SpiechowiczP. BialasJ. Łuczka
The paper derives a quantum partition-of-energy relation for a free Brownian particle within the Caldeira-Leggett model. The average kinetic energy of the particle equals the thermal kinetic energy of the thermostat per degree of freedom, averaged over oscillator frequencies weighted by a probability distribution $\mathbb{P}(\omega)$. The study examines how dissipation mechanisms—Drude, Gaussian, algebraic, and Debye spectral densities—affect $\mathbb{P}(\omega)$ and the particle's kinetic energy, highlighting the roles of coupling strength and memory time.
arXivarXiv · · April 16, 2019
0
Partition of energy for a dissipative quantum oscillator
P. BialasJ. SpiechowiczJ. Łuczka
The paper presents a quantum energy equipartition result for a dissipative harmonic oscillator coupled to a thermostat of harmonic oscillators. The mean kinetic and potential energies of the oscillator equal the corresponding mean energies per degree of freedom of the thermostat, each averaged twice: first over the Gibbs canonical state of the thermostat, and second over the thermostat oscillator frequencies via probability distributions $\mathbb{P}_k(\omega)$ and $\mathbb{P}_p(\omega)$. The roles of coupling strength and memory time are analyzed for Drude and algebraically decaying damping kernels.
arXivarXiv · · April 16, 2019
0
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
G. KorcylP. BiałasC. CurceanuE. CzerwińskiK. DulskiB. FlakA. GajosB. GłowaczM. GorgolB. C. HiesmayrB. JasińskaK. Kacprzak  +27
This paper proposes and evaluates a single-chip FPGA-SoC platform for real-time tomographic data processing using the J-PET scanner. The system directly connects to scanner data streams, performing event building, filtering, coincidence search, and region-of-response reconstruction in programmable logic, with visualization on integrated processors. It significantly reduces data volume by converting raw data to list-mode representation while generating on-the-fly visualization, eliminating the need for powerful local computing facilities.
arXivarXiv · · July 26, 2018
0
130
Quantum analogue of energy equipartition theorem
P. BialasJ. SpiechowiczJ. Luczka
This paper establishes a quantum analogue of the classical energy equipartition theorem. For a free quantum Brownian particle described by the Caldeira-Leggett model, the mean kinetic energy $E_k$ of the particle is shown to equal the mean kinetic energy $\langle \mathcal E_k \rangle$ per degree of freedom of the thermostat oscillators, i.e., $E_k = \langle \mathcal E_k \rangle$. This relation is derived from the fluctuation-dissipation theorem and is claimed to be universal for any linear or nonlinear system in contact with a bosonic thermostat.
arXivarXiv · · May 10, 2018
0
Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade
M.M. AggarwalZ. Ahammed…P. Bialas
This paper reports on the particle identification (PID) performance of a full-size prototype for the ALICE TPC upgrade, which replaces gated MWPCs with a stack of four Gas Electron Multiplier (GEM) foils to enable continuous readout at 50 kHz Pb–Pb collision rates. The prototype's specific energy loss ($dE/dx$) resolution meets the performance of the current MWPC-based chambers and the upgrade requirements. Data from a test beam campaign at the CERN PS are reproduced by detailed simulations.
arXivarXiv · · May 8, 2018
0
24
A multi-instance deep neural network classifier: application to Higgs boson CP measurement
P. BialasD. NemethE. Richter-Wąs
The paper frames the CP state measurement of the Higgs boson in $H\rightarrow\tau\tau$ decays as a binary classification problem. It introduces a multi-instance deep neural network classifier whose final score multiplies single-instance scores under the prior that instances in a series belong to the same class. The classifier shows strong training-epoch dependence, requiring careful threshold tuning. The authors derive a formula for the optimal threshold.
arXivarXiv · · March 2, 2018
0
1
Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner
R. MasełekW. KrzemienK. KlimaszewskiL. RaczyńskiP. KowalskiR. ShopaW. WiślickiP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. Gajos  +22
The authors propose an energy-based method to separate 511 keV annihilation photons from prompt de-excitation photons in the J-PET scanner for 2+1 photon tomography. By setting an energy deposited threshold, signals below the threshold are identified as 511 keV photons and those above as prompt photons. Analyzing several radioisotopes, they select $^{44}\mathrm{Sc}$ as the most promising candidate. Simulations with GATE and J-POS yield an optimal threshold of about 375 keV, achieving nearly 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.
arXivarXiv · · March 2, 2018
0
5
Human Tissues Investigation Using PALS Technique
B. JasińskaB. ZgardzińskaG. ChołubekM. GorgolK. WiktorK. WysogldP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. GajosB. Głowacz  +25
This study applies Positron Annihilation Lifetime Spectroscopy (PALS) to uterine leiomyoma and normal tissue from patients. Significant differences in all PALS parameters were observed between the two tissue types. Tumorous tissues showed longer free annihilation and ortho-positronium lifetimes than healthy tissues. For most patients, the intensities of these annihilation channels were lower in tumors. The paper's novel contribution is the first determination of the $3\gamma$ annihilation fraction in such studies, used to characterize changes in tissue porosity during morphological alteration.
arXivarXiv · · November 13, 2017
0
66
J-PET: a new technology for the whole-body PET imaging
S. NiedźwieckiP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. GajosB. GłowaczM. GorgolB. C. HiesmayrB. JasińskaŁ. KapłonD. Kisielewska-Kamińska  +21
J-PET is the first whole-body PET scanner built from plastic scintillators instead of conventional crystals. Its 192 detection modules are arranged axially in three layers, forming a 85-cm diameter cylindrical chamber with a 50-cm axial field of view. The long strips of plastic scintillators provide low light attenuation, superior timing, and easy scalability of the axial field of view, offering a cost-effective path to whole-body PET imaging and compatibility with MR and CT inserts.
arXivarXiv · · October 31, 2017
0
211
Introduction of total variation regularization into filtered backprojection algorithm
L. RaczyńskiW. WiślickiK. KlimaszewskiW. KrzemieńP. KowalskiR. ShopaP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. GajosB. Głowacz  +21
This paper extends the filtered backprojection (FBP) algorithm by introducing total variation (TV) regularization, replacing the common use of apodizing functions. The proposed method is validated on a Derenzo-type phantom and yields higher cross-correlation coefficients between the reconstructed and true radioactive tracer distribution compared to standard FBP, demonstrating improved reconstruction quality.
arXivarXiv · · October 31, 2017
0
1
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
R. Y. ShopaK. KlimaszewskiP. KowalskiW. KrzemieńL. RaczyńskiW. WiślickiP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. GajosB. Głowacz  +21
The paper presents a 3D image reconstruction method for the J-PET tomograph using Filtered Back Projection, implemented in the STIR and TomoPy packages. Simulated 511 keV annihilation photons from a 1 mm spherical source were detected by a cylindrical detector, with hit coordinates smeared to match experimental resolutions. Without time-of-flight information, consistent Point Spread Functions of approximately 5-7 mm transverse and 9-20 mm longitudinal were obtained using STIR.
arXivarXiv · · October 30, 2017
0
8
Commissioning of the J-PET detector for studies of decays of positronium atoms
E. CzerwińskiK. DulskiP. BiałasC. CurceanuA. GajosB. GłowaczM. GorgolB. C. HiesmayrB. JasińskaD. KisielewskaG. KorcylP. Kowalski  +20
The Jagiellonian PET (J-PET) detector, designed for whole-body medical imaging and physics studies of electron-positron annihilation, is shown to reject background in positronium decays due to its high angular and time resolution. This capability enables measurement of the positronium spin and the momenta and polarization vectors of annihilation quanta, extending the detector's utility beyond imaging into fundamental physics research.
arXivarXiv · · October 30, 2017
0
16
Time calibration of the J-PET detector
M. SkurzokM. SilarskiD. AlfsP. BialasShivaniC. CurceanuE. CzerwinskiK. DulskiA. GajosB. GlowaczM. GorgolB. C. Hiesmayr  +23
This paper presents the time calibration and synchronization of the J-PET scanner, a PET prototype for whole-body 3D imaging using organic scintillators. Each of the 192 scintillator strips arranged in three cylindrical layers is irradiated with a $^{22}\text{Na}$ source. A small detector provides a common reference time, enabling synchronization of all detector modules for high time- and angular-resolution imaging of annihilation photons.
arXivarXiv · · October 16, 2017
0
6
Analysis procedure of the positronium lifetime spectra for the J-PET detector
K. DulskiB. ZgardzinskaP. BialasC. Curceanu E. CzerwinskiA. GajosB. GłowaczM. GorgolB. C. HiesmayrB. JasinskaD. Kisielewska-KaminskaG. KorcylP. Kowalski  +21
The authors present a computer program for analyzing positronium lifetime spectra from the J-PET detector, which combines positron emission tomography with positron annihilation lifetime spectroscopy. The program uses an iterative fitting procedure and, when tested on hexane data at various temperatures, performs comparably to the standard LT 9.0 software.
arXivarXiv · · October 16, 2017
0
16
Multichannel FPGA based MVT system for high precision time (20~ps~RMS) and charge measurement
M. PałkaP. StrzempekG. KorcylT. BednarskiSz. NiedźwieckiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczM. GorgolB. Jasińska  +20
This paper presents a Multi-Voltage Threshold (MVT) system implemented on an FPGA that samples fast signals (1–2 ns edges) in voltage and time domains, achieving 20 ps RMS time precision and charge reconstruction within 10% error. By using FPGA differential inputs as comparators and an internal TDC, a compact 192-channel system with low power and cost is realized. Validated in a Time-of-Flight PET system, it achieves σ(TOF) ≈ 68 ps, twice better than current systems.
arXivarXiv · · July 12, 2017
0
114
Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation
L. RaczyńskiW. WiślickiW.KrzemieńP. KowalskiD. AlfsT. BednarskiP. BiałasC. CurceanuE. CzerwińskiK. DulskiA. GajosB. Głowacz  +22
The paper derives closed-form analytical formulas for the time resolution of the J-PET tomograph by combining Tikhonov regularization for signal processing with Kernel Density Estimation. The method is validated on signals from a single 30 cm plastic scintillator detection unit with vacuum tube photomultipliers, showing consistency between experimental and theoretical results.
arXivarXiv · · June 3, 2017
0
Measurement of gamma quantum interaction point in plastic scintillator with WLS strips
J. SmyrskiD. AlfsT. BednarskiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczN. Gupta-SharmaM. GorgolB. JasińskaM. Kajetanowicz  +20
This paper demonstrates that the axial coordinate of a gamma quantum interaction point inside a plastic scintillator bar can be measured by detecting scintillation photons escaping the bar with an array of wavelength-shifting (WLS) strips. Using a BC-420 scintillator bar and sixteen BC-482A WLS strips, a spatial resolution of 5 mm ($\sigma$) was achieved for annihilation photons from $^{22}$Na, suggesting a potential improvement for the J-PET collaboration's plastic-scintillator-based PET scanner.
arXivarXiv · · December 27, 2016
0
61
A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators
D. KamińskaA. GajosE. CzerwińskiD. AlfsT. BednarskiP. BiałasC. CurceanuK. DulskiB. GłowaczN. Gupta-SharmaM. GorgolB. C. Hiesmayr  +17
This paper demonstrates that the J-PET scanner, constructed from plastic scintillators rather than the inorganic crystals used in standard PET scanners, can measure angular and energy resolutions of $\sigma(\theta) \approx 0.4^{\circ}$ and $\sigma(E) \approx 4.1$ keV for ortho-positronium $3\gamma$ decays. While Compton scattering in plastic prevents direct energy measurement, the faster signal decay in plastic reduces pileup, allowing higher source activity to compensate for lower efficiency. Monte Carlo simulations confirm J-PET's suitability for studying discrete symmetries in o-Ps decays alongside medical imaging.
arXivarXiv · · July 28, 2016
0
113
Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
A. GajosD. KamińskaE. CzerwińskiD. AlfsT. BednarskiP. BiałasB. GłowaczM. GorgolB. JasińskaŁ. KapłonG. KorcylP. Kowalski  +19
This paper introduces a trilateration-based algorithm that simultaneously reconstructs the decay location and time of ortho-positronium atoms decaying into three photons using the positions and times of detected photons. Monte Carlo simulations with the J-PET detector yield a spatial resolution of about 2 cm (FWHM) in X and Y and 1 cm in Z after a kinematic fit. The method also enables discrimination of random three-photon background and a novel determination of ortho-positronium linear polarization, supporting tests of CP and CPT symmetries.
arXivarXiv · · February 24, 2016
0
91
Sampling FEE and Trigger-less DAQ for the J-PET Scanner
G. KorcylD. AlfsT. BednarskiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczB. JasińskaD. KamińskaŁ. KapłonP. Kowalski  +20
The paper presents a complete trigger-less data acquisition system for the J-PET tomography scanner. The readout chain continuously digitizes signals without preliminary selection, generating up to 8 Gbps. A Central Controller Module based on a Xilinx Zynq SoC with 16 optical transceivers performs online event building and feature extraction. Signal discrimination uses LVDS buffers in the FPGA. This trigger-less approach preserves most information for high-level processing, a novel method for such detector systems.
arXivarXiv · · February 17, 2016
0
61
Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
B. JasińskaM. GorgolM. WiertelR. ZaleskiD. AlfsT. BednarskiP. BiałasE. CzerwińskiK. DulskiA. GajosB. GłowaczD. Kamińska  +21
The paper selects a mesoporous material for experiments requiring a high yield of long-lived positronium, as needed for symmetry-violation studies with the J-PET scanner. By measuring $γ$-ray energy spectra and positron annihilation lifetime spectra, the fraction of 3$γ$ annihilation in various materials is found to range from 20% to 25%. The polymer XAD-4 yields the highest 3$γ$ fraction and o-Ps formation probability, and SEM-EDS confirms its high purity.
arXivarXiv · · February 17, 2016
0
69
Scatter fraction of the J-PET tomography scanner
P. KowalskiW. WiślickiL. RaczyńskiD. AlfsT. BednarskiP. BiałasE. CzerwińskiA. GajosB. GłowaczJ. JasińskaD. KamińskaG. Korcyl  +15
The J-PET collaboration is developing a plastic-scintillator Positron Emission Tomography system. This paper simulates the scatter fraction, a key background parameter defined by the NEMA-NU-2-2012 standard. Event selection methods are designed to suppress gamma quanta scattered in the phantom or undergoing multiple scattering in the detector. For the single-layer J-PET scanner, the estimated scatter fraction ranges from 37% to 53%, depending on the applied energy threshold.
arXivarXiv · · February 17, 2016
0
39
Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system
P. MoskalD. AlfsT. BednarskiP. BiałasE. CzerwińskiC. CurceanuA. GajosB. GłowaczM. GorgolB. C. HiesmayrB. JasińskaD. Kamińska  +15
The Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector capable of testing discrete symmetries in the purely leptonic positronium system. Positronium—a parity and charge conjugation eigenstate—decays into photons. J-PET can determine expectation values of discrete-symmetries-odd operators constructed from the ortho-positronium spin and the momenta and polarization vectors of its annihilation photons, enabling tests of C, CP, T, and CPT symmetries in the leptonic sector.
arXivarXiv · · February 16, 2016
0
125
Beam profile investigation of the new collimator system for the J-PET detector
E. KubiczM. SilarskiA. WieczorekD. AlfsT. BednarskiP. BiałasE. CzerwińskiA. GajosB. GłowaczB. JasińskaD. KamińskaG. Korcyl  +14
This paper presents three methods for determining the beam profile of collimated annihilation gamma quanta for the J-PET detector. The central contribution is the demonstration that using two lead bricks of dimensions 5x10x20 cm³ forms a beam with a Gaussian profile characterized by 1 mm full width at half maximum (FWHM). This precise profile characterization is essential for detector calibration and signal reconstruction, and simulations guided the selection of an optimal collimator system balancing beam profile parameters, dimensions, and weight for the 24-module J-PET prototype.
arXivarXiv · · February 16, 2016
0
8
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
P. MoskalO. RundelD. AlfsT. BednarskiP. BiałasE. CzerwińskiA. GajosK. GiergielM. GorgolB. JasińskaD. KamińskaŁ. Kapłon  +18
This paper introduces a method for recording timestamps of multiple photons at both ends of a plastic scintillator strip using a matrix of silicon photomultipliers (SiPM), aiming to improve the time resolution of the J-PET tomograph. Simulations show that the improvement saturates as the number of SiPM increases, and a 2x5 configuration at each end (reading twenty timestamps) is optimal. This configuration achieves a coincidence resolving time of approximately 0.170 ns for a 15 cm axial field-of-view and 0.365 ns for 100 cm, enabling a cost-effective TOF-PET scanner with better resolution and larger field-of-view.
arXivarXiv · · February 5, 2016
0
198
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
D. KamińskaT. BednarskiP. BiałasE. CzerwińskiA. GajosM. GorgolB. JasińskaŁ. KapłonG. KorcylP. KowalskiT. KozikW. Krzemień  +15
This paper describes prospects for using the J-PET detector to search for violation of CP and CPT symmetries in ortho-positronium decays into three photons. Non-zero expectation values of selected correlations between the ortho-positronium spin and photon momentum vectors would indicate physics beyond the Standard Model. The J-PET detector, which uses polymer scintillators instead of crystals, offers improved time and angular resolution and high geometrical acceptance, enabling constraints on violation parameters with better precision than the current ~10^{-3} level.
arXivarXiv · · September 3, 2015
0
14
Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy
E. KubiczB. JasińskaB. ZgardzińskaT. BednarskiP. BiałasE. CzerwińskiA. GajosM. GorgolD. KamińskaŁ. KapłonA. KochanowskiG. Korcyl  +17
The study applies Positron Annihilation Lifetime Spectroscopy (PALS) to characterize the hydration state of Saccharomyces cerevisiae. The ortho-positronium (o-Ps) lifetime shifts from 2.4 ns (lyophilized) to 2.9 ns (aqueous) for the longer-lived component, and from 1.2 ns to 1.4 ns for the shorter-lived component in dried yeasts, with full hydration reached within 10 hours. Environmental Scanning Electron Microscopy further reveals surface changes in the cell membrane between dry and wet states.
arXivarXiv · · August 30, 2015
0
Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance
N. G. SharmaM. SilarskiT. BednarskiP. BiałasE. CzerwińskiA. GajosM. GorgolB. JasińskaD. KamińskaŁ. KapłonG. KorcylP. Kowalski  +15
The J-PET detector, a Positron Emission Tomograph using polymer scintillator strips, requires precise reconstruction of the hit-time and hit-position of annihilation gamma quanta. This paper presents a reconstruction method that compares sampled photomultiplier signals (digitized at ~20 ps precision) against a library of model signals using the Mahalanobis distance as a similarity measure. The achievable resolution depends on the number and values of the sampling thresholds.
arXivarXiv · · August 29, 2015
0
20
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
A. WieczorekB. ZgardzińskaB. JasińskaM. GorgolT. BednarskiP. BiałasE. CzerwińskiA. GajosD. KamińskaŁ. KapłonA. KochanowskiG. Korcyl  +16
Positron annihilation lifetime spectroscopy (PALS) using the positronium probe reveals three structural transitions (at 260 K, 283 K, and 370 K) in a J-PET plastic scintillator based on a polystyrene matrix doped with 2,5-diphenyloxazole and 2-(4-styrylphenyl)benzoxazole, across 123–423 K. A significant hysteresis in the ortho-positronium intensity versus temperature is observed, and at 370 K, the intensity varies with time.
arXivarXiv · · August 27, 2015
0
10
Frequent collaborators
G. Korcyl (47)
Z. Rudy (47)
P. Moskal (47)
M. Silarski (46)
P. Kowalski (45)
T. Kozik (43)
E. Czerwiński (41)
M. Zieliński (41)
W. Krzemień (39)
L. Raczyński (39)
W. Wiślicki (38)
E. Kubicz (37)