Dosimetric and Deformation Effects of Image-Guided Interventions during Stereotactic Body Radiation Therapy of the Prostate using an Endorectal Balloon
Bernard L. JonesGregory GanQuentin DiotBKBrian Kavanagh
Robert D. TimmermanMoyed Miften Bernard L. Jones
Gregory Gan
Quentin Diot
BKBrian Kavanagh

Robert D. Timmerman
Moyed Miften
+6
This study assessed the dosimetric and deformation effects of manual endorectal balloon (ERB) interventions during prostate stereotactic body radiotherapy. Using daily cone-beam CT and deformable registration on 59 image sets from 35 fractions, interventions (re-inflation or repositioning) occurred in 69% of fractions. These interventions increased the prostate dose covering 95% of the PTV (D95) and coverage, reduced anterior-posterior deformation and sagittal rotation errors, and improved prostate shape similarity to the plan, confirming that such interventions are necessary to deliver the planned dose distribution.