Angular resolution measurements at SPring-8 of a hard X-ray optic for the New Hard X-ray Mission
D. SpigaL. RaimondiA. FuruzawaS. BassoR. BindaGBG. BorghiV. CotroneoG. GrisoniH. KuniedaF. MarioniH. MatsumotoH. Mori +9
D. Spiga
L. Raimondi
A. Furuzawa
S. Basso
R. Binda
GBG. Borghi
V. Cotroneo
G. Grisoni
H. Kunieda
F. Marioni
H. Matsumoto
H. Mori
+21
This paper reports hard X-ray angular resolution measurements of a multilayer-coated Wolter-I mirror shell, a demonstrator for the NHXM telescope (0.3–80 keV), performed at the SPring-8 BL20B2 beamline. To avoid finite-distance artifacts inherent in full-illumination tests of long-focal-length optics, a pencil-beam method was used, where the optic is tilted to compensate beam divergence. Reconstructed point-spread functions (PSFs) at 15–63 keV are presented and compared to PSFs computed from metrology data using Fresnel diffraction theory. The modeling accurately reproduces the measured PSFs.

arXiv ·