MCP
RD

R. DeVoe

59 papers in the library · Same-name authors told apart using DBLP

Papers

30
Estimating cosmogenic backgrounds in nEXO at SNOLAB using Geant4 and FLUKA
R. RossS. Al Kharusi…R. DeVoe
The nEXO experiment searches for neutrinoless double beta decay in $^{136}$Xe using a five-tonne liquid xenon TPC. This paper estimates its cosmogenic background rate at the underground SNOLAB site, comparing Geant4 and FLUKA Monte Carlo simulations of muon-induced spallation and neutron reactions. Only $^{137}$Xe, from neutron capture on xenon, is concerning. The authors devise a veto strategy achieving 92% rejection of $^{137}$Xe with under 1 day dead time per 10 years.
arXivarXiv · · October 31, 2026
0
0
EXO-200 Public Data Release for AI/ML Applications
S. Al KharusiG. Anton…R. DeVoe
This paper releases a subset of EXO-200 calibration data for AI/ML applications. Approximately one million events from $^{228}$Th calibration campaigns (February–March 2018) are provided in HDF5 format, containing raw U-wire, V-wire, and APD waveforms along with reconstructed quantities such as charge and light energy. The dataset supports data preservation, education, and the development of machine-learning techniques for rare-event physics.
arXivarXiv · · September 28, 2026
0
0
Design of a high voltage delivery system for noble liquid time projection chambers
R. SaldanhaL. PaganiE. AngelicoE. P. BernardB. ChanaS. DelaquisR. DeVoeM. ElbeltagiS. FerraraD. GoeldiR. GorneaA. Odian  +120
This paper presents a high voltage (HV) delivery system for noble liquid time projection chambers (TPCs), specifically designed for the nEXO neutrinoless double beta decay experiment. Building on prior HV research and experimental investigations, the authors identify factors that influence HV stability and propose design choices to prevent electrical discharges. The novel system incorporates these stability-enhancing measures while meeting nEXO's stringent radiopurity requirements, offering a practical design framework for future noble-liquid HV applications.
arXivarXiv · · February 27, 2026
0
1
Characterization of CRYO ASIC for charge readout in the nEXO experiment
Z. LiM. Yu…R. DeVoe
This work characterizes the CRYO ASIC, a cryogenic charge-readout chip designed to operate directly in liquid xenon (LXe) for the nEXO neutrinoless double beta decay experiment, thereby minimizing input capacitance and pick-up noise. Tested on an auxiliary printed circuit board in a cryogenic chamber and a dedicated LXe test stand, the ASICs achieved the desired performance at LXe temperatures, with gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration via an on-chip pulser. Boiling from chip heat dissipation was mitigated by operating above ~0.1 MPa, and measured in-LXe noise agreed with simulation, indicating the $150~e^-$ design requirement can be met, establishing the CRYO ASIC as a viable low-noise in-LXe solution for nEXO.
arXivarXiv · · December 11, 2025
0
1
Search for Double Beta Decays of 134^{134}Xe with EXO-200 Phase II
S. Al KharusiG. Anton…R. DeVoe
Using EXO-200 Phase II data from a detector with 19.098% $^{134}$Xe, the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decays of $^{134}$Xe finds no significant signal. A world-leading lower limit on the $0\nu\beta\beta$ half-life is set at $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ yr (90% C.L.), and the $2\nu\beta\beta$ limit is $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ yr (90% C.L.), three times stronger than the Phase I measurement. New constraints on decays to the lowest excited state of $^{134}$Ba are also reported.
arXivarXiv · · November 17, 2025
0
Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments
T. J. RoosendaalC. T. Overman…R. DeVoe
This paper evaluates chemical vapor deposition (CVD) nickel as a structural material for low-radioactivity instruments. CVD Ni achieves a planar tensile strength of ~600 MPa, significantly higher than standard nickel, and record-low bulk contaminations of $^{232}\\mathrm{Th}$ (~70 ppq), $^{238}\\mathrm{U}$ (<100 ppq), and $^{\\mathrm{nat}}\\mathrm{K}$ (~900 ppt). However, welding and heat treatment reduce strength to standard Ni levels, with weld porosity as a likely cause. Surface-etch profiling reveals higher contamination extending ~10 $\\mu$m below the surface from the aluminum substrate. These results establish CVD Ni as promising while highlighting needed improvements in welding and surface cleaning for rare-event search experiments.
arXivarXiv · · August 11, 2025
0
3
Sensitivity of nEXO to 136^{136}Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter
G. RichardsonB. G. Lenardo…R. DeVoe
nEXO's sensitivity to charged-current interactions of $\nu_e$ or fermionic dark matter with $^{136}$Xe is studied, exploiting a time-delayed coincident signal in the scintillation channel from low-lying isomeric states of $^{136}$Cs. A detailed Monte Carlo simulation shows that correlated signal can achieve background discrimination of $10^{-9}$, enabling background-free solar neutrino measurements above 0.668 MeV. nEXO could measure the CNO neutrino flux with 25% statistical uncertainty, constrain $^7$Be neutrino mean energy to $\sigma\leq1.5$ keV, and probe dark matter masses $m_\chi=0.668$-$7$ MeV with sensitivity up to three orders of magnitude better than current limits.
arXivarXiv · · June 27, 2025
0
3
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a 136^{136}Xe double beta decay experiment
M. YvaineD. Fairbank…R. DeVoe
This work extends single-atom barium imaging in solid xenon, relevant for $^{136}$Xe neutrinoless double-beta-decay background rejection, by detecting Ba atoms occupying a hexa-vacancy matrix site. Despite increased photobleaching at this site, imaging is achieved. The study observes abrupt fluorescence turn-off in single Ba atoms and demonstrates significant fluorescence recovery upon annealing of Ba deposits. Post-annealing, hexa-vacancy Ba atoms exhibit antibleaching while tetra-vacancy Ba atoms show bleaching, suggesting laser-induced matrix site transfer. These findings advance barium tagging across all relevant sites in solid xenon.
arXivarXiv · · June 29, 2024
0
0
Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200
S. LiI. Ostrovskiy…R. DeVoe
This work demonstrates a Wasserstein Generative Adversarial Network to simulate photodetector signals from the EXO-200 time projection chamber. Trained on raw scintillation waveforms from real calibration data, the network produces high-quality simulated waveforms an order of magnitude faster than traditional simulation. It generalizes beyond the training sample, correctly learning position-dependent scintillation response and identifying dead channels. When integrated into the EXO-200 analysis framework, the simulated waveforms yield energy distributions comparable to real data, though some discrepancies remain.
arXivarXiv · · March 11, 2023
0
6
Search for Two-neutrino Double-Beta Decay of 136Xe^{136}\rm Xe to the 01+0^+_1 excited state of 136Ba^{136}\rm Ba with the Complete EXO-200 Dataset
EXO-200 CollaborationS. Al Kharusi…R. DeVoe
A search for two-neutrino double-beta decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ uses the complete EXO-200 dataset. A convolutional neural network doubles detection efficiency over previous EXO-200 analyses. The median 90% confidence level half-life sensitivity is $2.9 \times 10^{24}~\rm yr$ with a $234.1~\rm kg~yr$ exposure. No significant signal is found, yielding a lower limit $T^{2\nu}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90% CL, a 70% improvement over the previous best constraint.
arXivarXiv · · March 2, 2023
0
0
Search for MeV Electron Recoils from Dark Matter in EXO-200
EXO-200 CollaborationS. Al Kharusi…R. DeVoe
Using 234.1 kg yr of ¹³⁶Xe exposure in the EXO-200 detector, a search for electron recoils from charged-current dark matter absorption finds no significant excess above a background of $6.8 \times 10^{-4}$ cts kg⁻¹ yr⁻¹ keV⁻¹ above 4 MeV. This excludes new parameter space for the absorption cross-section for dark matter masses $m_\chi = 2.6$–$11.6$ MeV, with a minimum excluded cross-section of $6 \times 10^{-51}$ cm² at $m_\chi = 8.3$ MeV at 90% CL.
arXivarXiv · · July 2, 2022
0
18
Development of a 127^{127}Xe calibration source for nEXO
B. G. LenardoC. A. Hardy…R. DeVoe
The authors propose a $^{127}$Xe electron capture source for in-situ calibration of the nEXO experiment, which searches for neutrinoless double beta decay ($0\nu\beta\beta$) using a 5-tonne liquid xenon TPC. With a 36.3-day half-life and a small $Q$-value, $^{127}$Xe can be maintained continuously in the detector without adding backgrounds, enabling calibration of position- and time-dependent response. The work describes source production, preliminary tests, and simulations projecting the precision of spatial corrections to light and charge response.
arXivarXiv · · January 12, 2022
0
8
Search for Majoron-emitting modes of 136^{136}Xe double beta decay with the complete EXO-200 dataset
S. Al KharusiG. Anton…R. DeVoe
Using the full EXO-200 dataset (234.1 kg·yr of $^{136}$Xe exposure), including upgraded detector data with a lower energy threshold, the collaboration set a new lower limit on the half-life of the spectral index $n=1$ Majoron-emitting neutrinoless double-beta decay of $^{136}$Xe: $T_{1/2}^{\rm{^{136}Xe}} > 4.3 \cdot 10^{24}$ yr at 90% C.L. This result is 3.6 times more stringent than the previous EXO-200 limit, constraining the Majoron-neutrino coupling to $|\langle g_{ee}^{M}\rangle| < (0.4-0.9) \cdot 10^{-5}$. For the $n=7$ mode, the improvement is 8.4-fold, yielding the most stringent limits to date for $n=1,2,3,7$.
arXivarXiv · · September 3, 2021
0
33
NEXO: Neutrinoless double beta decay search beyond 102810^{28} year half-life sensitivity
nEXO CollaborationG. Adhikari…R. DeVoe
The nEXO experiment, using a time projection chamber with 5000 kg of enriched liquid xenon, targets neutrinoless double beta decay in $^{136}$Xe. Updated detector design, higher-fidelity simulation, and advanced analysis based on EXO-200 yield a predicted half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level over 10 years, covering the inverted neutrino mass ordering parameter space and most of the normal ordering for nearly all nuclear matrix elements. The design incorporates custom electroformed copper to reduce material backgrounds, and the model is robust against several background deviations.
arXivarXiv · · June 30, 2021
0
388
Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory
S. Al KharusiG. Anton…R. DeVoe
The EXO-200 experiment measured the first-forbidden non-unique β-decay $^{137}\mathrm{Xe}(7/2^-)\to\,^{137}\mathrm{Cs}(7/2^+)$ using an AmBe neutron source. With a signal-to-background ratio exceeding 99-to-1 in the 1075–4175 keV range, the resulting spectral shape provides a rare, accurate test of theoretical predictions relevant to the reactor antineutrino anomaly and spectral bump.
arXivarXiv · · February 1, 2020
0
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
P. LvG.F. Cao…R. DeVoe
This paper reports the angular and spectral dependence of specular reflectance of SiPMs from FBK and Hamamatsu in the 120 nm–280 nm vacuum ultraviolet range. The refractive index and extinction coefficient of the SiO₂ film on FBK SiPMs are derived from reflectance measurements of a reference wafer. Diffuse reflectance at 193 nm is also measured. The optical constants are used to predict reflectance in liquid xenon, which is relevant for large-scale photodetector systems.
arXivarXiv · · December 4, 2019
0
24
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
O. NjoyaT. Tsang…R. DeVoe
The authors report measurements of electron drift properties in liquid and gaseous xenon. Using a laser-driven gold photocathode in a small chamber with a 2.0 cm drift distance, they measure drift velocities and longitudinal diffusion coefficients. At 0.5 kV/cm, the drift velocity in liquid xenon is $1.97 \pm 0.04$ mm/$\mu$s with a temperature coefficient of $(-0.69\pm0.05)$\%/K; in gaseous xenon at 1.5 bar, it is $1.42 \pm 0.03$ mm/$\mu$s with $(+0.11\pm0.01)$\%/K. Diffusion coefficients are $25.7 \pm 4.6$ cm$^2$/s (liquid) and $149 \pm 23$ cm$^2$/s (gas). The photocathode's quantum efficiency is also studied.
arXivarXiv · · November 25, 2019
0
34
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
P. NakarmiI. Ostrovskiy…R. DeVoe
This paper reports the first measurement of specular reflectivity and relative photodetection efficiency (PDE) of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μm micro-cells in liquid xenon using xenon scintillation light (~175 nm). At 15° incidence, specular reflectivity of three samples is 30.4±1.4%, 28.6±1.3%, and 28.0±1.3%, respectively. PDE at normal incidence varies by ±8% (standard deviation) among devices. Both reflectivity and PDE decrease with increasing incidence angle.
arXivarXiv · · October 14, 2019
0
32
Simulation of charge readout with segmented tiles in nEXO
Z. LiW.R. Cen…R. DeVoe
nEXO, a proposed tonne-scale liquid xenon TPC searching for $0\nu\beta\beta$ decay of $^{136}$Xe, uses segmented charge-collection tiles as its anode. A dedicated simulation shows that a multi-variate method and a deep neural network can distinguish signal from radioactive backgrounds. The estimated half-life sensitivity improves by $\sim$20\% with the multi-variate method and $\sim$32\% with the deep neural network, relative to the pre-conceptual design report.
arXivarXiv · · July 17, 2019
0
29
Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset
G. AntonI. Badhrees…R. DeVoe
Using the complete EXO-200 dataset, a search for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{136}$Xe employs a deep neural network to distinguish signal from background. The analysis achieves a signal detection efficiency of $96.4\pm3.0\%$ and an energy resolution of $\sigma/E=1.15\pm0.02\%$ at the $Q$-value. With a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, the median 90% confidence level half-life sensitivity is $5.0 \cdot 10^{25}$ yr. No significant evidence for $0\nu\beta\beta$ is found, yielding a lower half-life limit of $3.5\cdot10^{25}$ yr at 90% confidence.
arXivarXiv · · June 6, 2019
0
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
G. GallinaP. Giampa…R. DeVoe
The Hamamatsu VUV4 MPPC was characterized for the nEXO experiment's liquid xenon scintillation detection. At 163 K and 3.1 V over voltage, correlated avalanches per pulse (0.161±0.005) and dark-noise rate (0.137 Hz/mm²) meet nEXO specifications. However, its photon detection efficiency at 189 nm and 233 K (13.4% and 11% for two devices) falls well below the advertised 24% saturation PDE, with the second device also below nEXO's requirement. The first device's PDE is marginally close, suggesting that modest improvements could make it a viable alternative to FBK-LF SiPMs.
arXivarXiv · · March 8, 2019
0
94
Study of Silicon Photomultiplier Performance in External Electric Fields
X.L. SunT. Tolba…R. DeVoe
This study reports that silicon photomultiplier (SiPM) light sensors maintain stable gain, photon detection efficiency, and correlated-pulse rates when exposed to external electric fields up to 30 kV/cm at 149 K, with no observable physical damage. The results confirm that SiPM performance is unaffected by strong external fields under these conditions.
arXivarXiv · · July 9, 2018
0
15
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
C. ChambersT. Walton…R. DeVoe
This paper demonstrates the first imaging of individual barium atoms in solid xenon, a key step toward barium tagging in the nEXO neutrinoless double beta decay experiment. By scanning a focused laser across a solid xenon matrix on a sapphire window, individual atoms are identified by fluorescence that persists for ~30 s before dropping abruptly to background. This establishes the practical principle for tagging the 136Ba daughter from 136Xe double beta decay to eliminate backgrounds in nEXO.
arXivarXiv · · June 27, 2018
0
74
nEXO Pre-Conceptual Design Report
nEXO CollaborationS. Al Kharusi…R. DeVoe
The nEXO pre-Conceptual Design Report describes a tonne-scale neutrinoless double beta ($0\nu\beta\beta$) decay search using $\simeq$ 5000 kg of xenon enriched to 90% in $^{136}$Xe, based on the liquid xenon technology validated by EXO-200. The projected half-life sensitivity is approximately $10^{28}$ years, an improvement of about two orders of magnitude over current results. The background is expected to be dominated by external radiation, so the sensitivity gain comes primarily from the increased active mass in a monolithic detector, with risk reduced by leveraging demonstrated intrinsic contamination levels.
arXivarXiv · · May 28, 2018
0
98
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
S. DelaquisM.J. Jewell…R. DeVoe
This paper applies deep neural networks (DNN) to raw digitized waveforms from EXO-200 to reconstruct total energy and position. The DNN is evaluated on real calibration data, achieving accuracy that matches or exceeds conventional methods. Crucially, the network is trained on experimental waveforms, reducing or eliminating reliance on Monte Carlo simulation, which typically limits the accuracy of DNN-based approaches in particle physics.
arXivarXiv · · April 25, 2018
0
73
Search for nucleon decays with EXO-200
J.B. AlbertG. Anton…R. DeVoe
Using 223 kg·yr of $^{136}$Xe exposure from EXO-200, the first search for nucleon decay in xenon isotopes sets lower partial lifetime limits of $3.3 \times 10^{23}$ yr (to $^{133}$Sb) and $1.9 \times 10^{23}$ yr (to $^{133}$Te), surpassing previous limits by factors of 9 and 7 to become the most stringent for these channels.
arXivarXiv · · October 20, 2017
0
28
Characterization of an Ionization Readout Tile for nEXO
nEXO CollaborationM. JewellA. SchubertW.R. CenJ. DalmassonR. DeVoeL. FabrisG. GrattaA. JamilG. LiA. OdianM. Patel  +133
This paper characterizes a charge-detecting tile for the nEXO neutrinoless double-beta decay experiment. The tile has 60 orthogonal metal strips on a 10 cm fused-silica wafer, replacing the conventional Frisch grid and wire structure to reduce radioactive backgrounds and cryogenic complexity. A prototype tested in liquid xenon with a ²⁰⁷Bi source achieves an energy resolution σ/E = 5.5% at 570 keV, matching simulations that include xenon recombination and detailed electrostatic modeling.
arXivarXiv · · October 14, 2017
0
45
Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
nEXO CollaborationJ.B. Albert…R. DeVoe
The proposed nEXO experiment aims to search for neutrinoless double beta decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years, using $5\times10^3$ kg of enriched liquid-xenon in a time projection chamber. This two-order-of-magnitude improvement over current limits arises from increased $^{136}$Xe mass, the monolithic active medium, and multi-parameter interaction measurements, based on demonstrated realizable background rates.
arXivarXiv · · October 13, 2017
0
Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector
J.B. AlbertG. Anton…R. DeVoe
Using the first year of data from the upgraded EXO-200 detector, a search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{136}$Xe is reported. Improvements include enhanced energy resolution ($\sigma/E = 1.23\%$), a 50% higher drift-region electric field, radon suppression, and better topological discrimination. Combining these with pre-upgrade data yields a median sensitivity of $3.7 \times 10^{25}$ yr at 90% confidence. No significant signal is observed, setting a lower half-life limit of $1.8 \times 10^{25}$ yr.
arXivarXiv · · July 27, 2017
0
366
Searches for Double Beta Decay of 134^{134}Xe with EXO-200
EXO-200 CollaborationJ.B. Albert…R. DeVoe
Using EXO-200, a detector originally designed for $^{136}$Xe, the first dedicated search for $^{134}$Xe double beta decay set lower limits on half-lives: $T_{1/2}^{2\nu\beta\beta} > 8.7 \times 10^{20}$ yr and $T_{1/2}^{0\nu\beta\beta} > 1.1 \times 10^{23}$ yr at 90% confidence level, based on $29.6\text{ kg}\cdot\text{yr}$ exposure. These limits improve on previous results by factors of nearly $10^{5}$ and 2 for the two-neutrino and neutrinoless modes, respectively.
arXivarXiv · · April 17, 2017
0
Frequent collaborators
G. Gratta (59)
A. Piepke (56)
A. Odian (55)
A. Pocar (55)
B. Mong (52)
V. Stekhanov (52)
L. Yang (50)
T. Daniels (49)
J. Farine (49)
A. Kuchenkov (49)
R. MacLellan (49)
R. Gornea (48)