MCP
SA

S. Akers

3 papers in the library

Papers

3
In-Flight Performance of Spider's 280 GHz Receivers
Elle C. ShawP. A. R. AdeS. AkersM. AmiriJ. AustermannJ. BeallD. T. BeckerS. J. BentonA. S. BergmanJ. J. BockJ. R. BondS. A. Bryan  +75
The SPIDER balloon-borne instrument mapped the cosmic microwave background during its second flight (2022–2023) with new 280 GHz receivers. Each receiver uses an array of transition-edge sensors coupled to the sky through feedhorns made from stacked silicon wafers, optimized to map polarized Galactic dust emission over a large area. This article reports the receivers' in-flight performance, including optical loading at float altitude and an early detector noise analysis, providing a unique dataset for future studies.
arXivarXiv · · August 19, 2024
0
Design and pre-flight performance of SPIDER 280 GHz receivers
E. C. ShawP. A. R. AdeS. AkersM. AmiriJ. AustermannJ. BeallD. T. BeckerS. J. BentonA. S. BergmanJ. J. BockJ. R. BondS. A. Bryan  +70
The paper describes upgrades to the Spider balloon-borne telescope for its second flight, focusing on the design and pre-flight performance of three new 280 GHz receivers. These receivers incorporate over 1500 feedhorn-coupled transition-edge sensors and are characterized through laboratory measurements of detector properties and optical performance. Their primary contribution is to map polarized Galactic dust emission at 280 GHz, which will help separate this foreground from the primordial B-mode polarization signal in the cosmic microwave background, the main scientific target of the instrument.
arXivarXiv · · December 22, 2020
0
4
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
A.S. BergmanP.A.R. AdeS. AkersM. AmiriJ.A. AustermannJ.A. BeallD.T. BeckerS.J. BentonJ.J. BockJ.R. BondS.A. BryanH.C. Chiang  +67
This paper presents the design and characterization of 280 GHz focal plane units (FPUs) for the balloon-borne SPIDER-2 instrument, aiming to constrain B-mode contamination from Galactic dust in the cosmic microwave background. Each FPU comprises a 16×16 grid of corrugated silicon feedhorns coupled to aluminum-manganese transition-edge sensor (TES) bolometers. Three FPUs collectively provide 1,530 polarization-sensitive bolometers (765 spatial pixels). Cryogenic measurements show high uniformity: median saturation power is ~3 pW at 300 mK, varying less than 6% across each array, with one array achieving 95% yield.
arXivarXiv · · November 11, 2017
0
20
Frequent collaborators
M. Amiri (3)
O. Doré (3)
M. Farhang (3)
K. Freese (3)
M. Galloway (3)
K. Ganga (3)
A. Grigorian (3)
R. Gualtieri (3)
M. Halpern (3)
J. Hartley (3)
M. Hasselfield (3)
G. Hilton (3)