MCP
SA

S. Azzoni

22 papers in the library

Papers

22
LiteBIRD Mission Overview after Mission Reformation
LiteBIRD CollaborationK. AizawaH. AkamatsuR. AkizawaE. AllysA. AnandD. AudleyJ. AumontS. AzzoniC. BaccigalupiM. BallardiniA. J. Banday  +163
LiteBIRD, a JAXA-led space mission, aims to measure the cosmic microwave background $B$-mode polarization to test inflationary models. After a 2024 reformation, the payload now uses a single 500-mm cross-Dragone telescope cooled to 5~K, covering 12 frequency bands from 40 to 402~GHz, coupled to 0.1~K transition-edge-sensor bolometers. The primary goal is a total uncertainty in the tensor-to-scalar ratio of $\delta r < 0.002$ (68% C.L.) from a 3-year survey at Sun-Earth L2.
arXivarXiv · · July 28, 2026
0
6
The Simons Observatory: forecasted constraints on primordial gravitational waves with the expanded array of Small Aperture Telescopes
The Simons Observatory CollaborationI. Abril-Cabezas…S. Azzoni
By expanding the Small Aperture Telescopes (SATs) from three to six and extending the survey to 2035, the Simons Observatory is forecast to achieve a $1\sigma$ constraint on the tensor-to-scalar ratio $r$ of $\sigma_r = 1.2\times10^{-3}$, assuming no primordial $B$-modes. This represents a factor of about 2.5 improvement over the original design, based on a $1/f$ noise model and a moderately complex foreground model, with 70% delensing from the Large Aperture Telescope.
arXivarXiv · · December 17, 2025
0
12
The Simons Observatory: Science Goals and Forecasts for the Enhanced Large Aperture Telescope
Simons Observatory CollaborationM. Abitbol…S. Azzoni
The Simons Observatory will upgrade its 6-meter Large Aperture Telescope by 2028, doubling mapping speed with 30,000 new detectors and an automated pipeline, and switching to a photovoltaic power supply. The survey will cover 60% of the sky at five times Planck's resolution and ten times the depth. The central science goal is to constrain the physics of the early universe and new light particles, measure neutrino mass and dark energy via tomographic structure growth at $z < 3$, and produce samples of over 30,000 galaxy clusters and 100,000 extragalactic millimeter sources.
arXivarXiv · · March 1, 2025
0
172
Requirements on the gain calibration for LiteBIRD polarisation data with blind component separation
F. CarralotA. CaronesN. KrachmalnicoffT. GhignaA. NovelliL. PaganoF. PiacentiniC. BaccigalupiD. AdakA. AnandJ. AumontS. Azzoni  +97
This work derives requirements on the relative calibration accuracy of the overall polarization gain ($\Delta g_\nu$) for the LiteBIRD experiment using the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. The tightest constraint is $\Delta g_\nu \approx 0.16\%$ at 166 GHz, where the CMB signal is brightest. When these requirements are applied to all channels simultaneously, the impact on the tensor-to-scalar ratio $r$ is a factor of 5 below the LiteBIRD budget. However, under a high-complexity sky model the requirements must be tightened by a factor of 1.8.
arXivarXiv · · November 4, 2024
0
7
The LiteBIRD mission to explore cosmic inflation
T. GhignaA. AdlerK. AizawaH. AkamatsuR. AkizawaE. AllysA. AnandJ. AumontJ. AustermannS. AzzoniC. BaccigalupiM. Ballardini  +147
LiteBIRD, a JAXA-led L-class mission launching in 2032, will map the full-sky CMB polarization from L2 to constrain inflation. With three telescopes covering 34–448 GHz, the experiment targets a sensitivity of 2.2 $\mu$K-arcmin and resolution of 0.5° at 100 GHz. Its central contribution is measuring the tensor-to-scalar ratio $r$ to an uncertainty $\delta r=0.001$ (including systematics), enabling a $>5\sigma$ detection of $r\geq0.01$ in two separate multipole ranges.
arXivarXiv · · June 4, 2024
1
23
LiteBIRD Science Goals and Forecasts: A full-sky measurement of gravitational lensing of the CMB
A. I. LonappanT. Namikawa…S. Azzoni
LiteBIRD's full-sky polarization maps, with a 30 arcmin beam and 2.16 μK-arcmin polarization noise, will enable a nearly full-sky lensing reconstruction using only polarization data. After removing Galactic foregrounds via harmonic-space internal linear combination, the lensing signal-to-noise ratio is about 40 over 90% of the sky. This is comparable to Planck's lensing measurement using both temperature and polarization, and a four-fold improvement over Planck's polarization-only measurement.
arXivarXiv · · December 8, 2023
0
21
LiteBIRD Science Goals and Forecasts: Improving Sensitivity to Inflationary Gravitational Waves with Multitracer Delensing
T. NamikawaA. I. Lonappan…S. Azzoni
The LiteBIRD experiment's sensitivity to the tensor-to-scalar ratio $r$ is increasingly limited by lensing $B$-mode polarization rather than foregrounds. This paper evaluates the improvement from combining multiple external lensing-mass tracers—CMB lensing maps from LiteBIRD and a CMB-S4-like experiment, cosmic infrared background, and galaxy surveys from Euclid and LSST—for delensing. Multi-tracer delensing reduces the lensing contribution and improves the constraint on $r$ by about 20% compared to single-tracer methods. Further foreground reduction would make delensing even more impactful.
arXivarXiv · · December 8, 2023
0
33
Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations
U. FuskelandJ. Aumont…S. Azzoni
LiteBIRD, a satellite mission targeting the CMB B-mode polarization, aims to detect primordial gravitational waves via the tensor-to-scalar ratio $r$ with uncertainty $\delta r < 0.001$. Because the CMB spectrum falls off steeply above 300 GHz relative to thermal dust emission, extending the high-frequency coverage can improve component separation. The paper shows that shifting the upper frequency cutoff from 400 to 600 GHz reduces the statistical uncertainty on $r$ by 30–50% under a spatially varying dust model, with most improvement already at 500 GHz.
arXivarXiv · · February 10, 2023
0
38
The Simons Observatory: pipeline comparison and validation for large-scale B-modes
K. WolzS. AzzoniC. Hervias-CaimapoJ. ErrardN. KrachmalnicoffD. AlonsoC. BaccigalupiA. Baleato LizancosM. L. BrownE. CalabreseJ. ChlubaJ. Dunkley  +5
The Simons Observatory Small Aperture Telescopes target a constraint on the primordial tensor-to-scalar ratio $r$ with $\sigma(r=0)\lesssim0.003$. This paper presents three analysis pipelines for constraining $r$ from simulated realistic frequency maps, using different combinations of parametric and non-parametric component separation and B-mode purification. In most scenarios, the three pipelines achieve similar performance. However, complex foregrounds can cause a $>2\sigma$ bias on $r$ with the default versions, motivating two extensions—using power-spectrum-based and map-based methods—that reduce the bias below statistical uncertainties in all explored foreground models, at a moderate cost in $\sigma(r)$.
arXivarXiv · · February 8, 2023
0
58
Contribution to the 2022 Cosmology session of the 56th Rencontres de Moriond: Moment expansion of polarized dust SED: A new path towards capturing the CMB BB-modes with LiteBIRD
L. VacherJ. AumontL. MontierS. AzzoniF. BoulangerM. Remazeilles
This paper presents a moment expansion of the polarized dust spectral energy distribution (SED) as a method to avoid biases in CMB $B$-mode analyses. Applied to simulated LiteBIRD polarization data (100--402 GHz), the approach yields an unbiased measurement of the tensor-to-scalar ratio $r$ with dispersion compatible with the instrument's target values, without requiring strong assumptions on dust complexity.
arXivarXiv · · March 14, 2022
0
Probing Cosmic Inflation with the LiteBIRD Cosmic Microwave Background Polarization Survey
LiteBIRD CollaborationE. AllysK. ArnoldJ. AumontR. AurlienS. AzzoniC. BaccigalupiA. J. BandayR. BanerjiR. B. BarreiroN. BartoloL. Bautista  +179
LiteBIRD is a JAXA-led L-class space mission to map the full-sky cosmic microwave background polarization in 15 frequency bands at 34–448 GHz, targeting a total sensitivity of 2.2 μK-arcmin. Its primary scientific goal is to detect or rule out well-motivated models of cosmic inflation by searching for the B-mode polarization signal, which would also probe quantum gravity and new physics beyond the standard models.
arXivarXiv · · February 6, 2022
0
662
Moment expansion of polarized dust SED: a new path towards capturing the CMB BB-modes with LiteBIRD\textit{LiteBIRD}
L. VacherJ. AumontL. MontierS. AzzoniF. BoulangerM. Remazeilles
For LiteBIRD to achieve its target accuracy on the tensor-to-scalar ratio $r$ (∼1e-3), the complex spectral energy distribution (SED) of polarized Galactic dust must be correctly modeled. A moment expansion of the dust SED, which imposes minimal assumptions, is applied to simulated LiteBIRD $B$-mode cross-angular power spectra at 100–402 GHz. Expanding only in the spectral index $\beta$ reduces bias but does not yield reliable $r$ estimates. The authors introduce for the first time an expansion in both $\beta$ and temperature $T$, showing that accounting for $T$ variations is necessary to avoid biases. With this expansion, an unbiased $r$ is recovered with uncertainty $\sigma(r)=8.8\times10^{-4}$.
arXivarXiv · · November 15, 2021
0
QUBIC IV: Performance of TES Bolometers and Readout Electronics
M. PiatG. Stankowiak…S. Azzoni
QUBIC IV reports the performance of its 256 NbSi transition edge sensor (TES) bolometers and time-domain multiplexing readout. The low-noise amplifier achieved 0.3 nV/Hz$^{-0.5}$ white noise, and about 80% of detectors operated within specifications. The instrument noise equivalent power was about 2×10$^{-16}$ W/Hz$^{-0.5}$, sufficient for demonstrating bolometric interferometry, though limited by microphonics and noise aliasing.
arXivarXiv · · January 17, 2021
0
36
A minimal power-spectrum-based moment expansion for CMB B-mode searches
S. AzzoniM. H. AbitbolD. AlonsoA. GoughN. KatayamaT. Matsumura
To mitigate foreground modeling biases in primordial B-mode searches, this paper proposes a power-spectrum-based moment expansion that captures spectral index variations across the sky using a small set of physically interpretable parameters. Validated on Simons Observatory-like simulations, the method recovers an unbiased tensor-to-scalar ratio $r$ with standard deviation $\sigma(r)\approx 0.003$. Applied to BICEP2/Keck data, it yields an upper bound $r<0.06$ (95% C.L.), consistent with previous decorrelation-based results. The approach is directly applicable to ground-based multi-frequency surveys.
arXivarXiv · · November 23, 2020
0
QUBIC I: Overview and ScienceProgram
J.-Ch. HamiltonL. Mousset…S. Azzoni
QUBIC is a novel bolometric interferometer for CMB B-mode polarization that combines the systematic-error control of interferometry with the wide-band sensitivity of bolometers. Its synthesized beam's frequency-dependent shape enables multi-sub-band polarization mapping within the 150 and 220 GHz bands, aiding foreground removal. Simulations for three years of observation from Argentina, assuming perfect foreground subtraction and stable atmosphere, yield a statistical sensitivity to the effective tensor-to-scalar ratio of $\sigma(r)=0.015$.
arXivarXiv · · November 4, 2020
0
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
L. MoussetM.M. Gamboa Lerena…S. Azzoni
This paper reports that bolometric interferometry enables spectral imaging, allowing a single instrument to reconstruct sky maps in multiple sub-bands from a wide frequency band. Using the QUBIC instrument, the authors demonstrate point-source reconstruction and Galactic dust mapping, characterize the frequency-dependent point spread function, and study noise correlations between sub-bands via simulations. They conclude that with QUBIC, spectral imaging performance is nearly optimal for up to five sub-bands, offering a method to separate CMB B-mode polarization from astrophysical foregrounds.
arXivarXiv · · October 28, 2020
0
0
QUBIC V: Cryogenic system design and performance
S. MasiE.S. Battistelli…S. Azzoni
The QUBIC experiment's cryogenic system, designed for long-duration CMB polarization measurements, is presented. The system uses two pulse-tube refrigerators to cool a ~1 m³, ~165 kg instrument to ~3K. A ⁴He evaporator cools the beam combiner to ~1K, and a ³He evaporator cools the detector arrays to ~0.33K. The system operated stably for over six months, and tilting from 20° to 90° elevation caused no significant temperature changes, confirming readiness for deployment.
arXivarXiv · · August 24, 2020
0
29
QUBIC VI: cryogenic half wave plate rotator, design and performances
G. D&#39;AlessandroL. Mele…S. Azzoni
The QUBIC Stokes polarimeter rotates a half-wave plate (HWP) at cryogenic temperature to modulate polarization while minimizing spurious signals from optical element emissivity. Its rotation is driven by an external stepper motor to avoid thermal load at low temperature. Tests show positioning precision below 0.1° and an extra power load of only a few mK on the ~8 K cryogenic stage.
arXivarXiv · · August 24, 2020
0
QUBIC III: Laboratory Characterization
S.A. TorchinskyJ.-Ch. Hamilton…S. Azzoni
The QUBIC Technological Demonstrator successfully validates bolometric interferometry through laboratory characterization. A prototype scanned a far-field modulated millimeter-wave source to produce synthesized beam maps, achieving measured beams matching theoretical simulations and enabling spectro-imaging. Polarization performance showed less than 0.5% cross-polarization rejection. The instrument is now ready for deployment in Argentina.
arXivarXiv · · August 23, 2020
0
28
QUBIC VIII: Optical design and performance
C. O&#39;SullivanM. De Petris…S. Azzoni
QUBIC uses bolometric interferometry to detect CMB B-mode polarisation around the recombination peak. A cold reflective combiner overlays beams from 400 feedhorns onto two focal planes, combining imager sensitivity with interferometer systematic-error control. A fixed groundshield and a moving forebaffle limit local contamination. The paper presents the optics modelling, design, manufacturing, and preliminary measurements.
arXivarXiv · · August 23, 2020
0
36
QUBIC: the Q & U Bolometric Interferometer for Cosmology
E.S. BattistelliP. AdeJ.G. AlberroA. AlmelaG. AmicoL. H. ArnaldiD. AugusteJ. AumontS. AzzoniS. BanfiP. BattagliaA. Baù  +127
QUBIC combines Transition Edge Sensor bolometers with interferometric techniques to measure the faint polarization signal of the cosmic microwave background left by inflation. This hybrid design achieves the sensitivity of cryogenic detectors and the systematic-error control of an interferometer, distinguishing it from classical imaging CMB experiments. The instrument, demonstrated in the lab, will be deployed in Argentina at the end of 2019.
arXivarXiv · · January 28, 2020
0
21
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
M. PiatB. Bélier…S. Azzoni
QUBIC is a ground-based CMB experiment that measures polarized fluctuations using bolometric interferometry, combining the systematic-immunity of an interferometer with the sensitivity of cryogenic detectors. Its detection chain uses 2048 NbSi Transition Edge Sensors (TESs) cooled to 350 mK, read out via time-domain multiplexing (MUX factor 128) with SQUIDs at 1 K and a SiGe ASIC at 60 K. Characterization results from a reduced detector setup are presented, focusing on the detectors and readout system.
arXivarXiv · · November 27, 2019
0
Frequent collaborators
J. Aumont (18)
L. Montier (18)
G. Pisano (18)
M. Zannoni (18)
M. Bersanelli (16)
F. Columbro (16)
P. de Bernardis (16)
C. Franceschet (16)
M. Gervasi (16)
L. Lamagna (16)
S. Masi (16)
A. Paiella (16)