MCP
SB

S. Basso

16 papers in the library

Papers

16
The International Axion Observatory (IAXO): case, status and plans. Input to the European Strategy for Particle Physics
A. ArcusaS. AhyouneK. AltenmullerI. AntolinS. BassoP. BrunV. BurwitzF. R. CandonJ. F. CastelS. CebrianD. ChouhanR. Della Ceca  +111
The International Axion Observatory (IAXO) is a next-generation helioscope that will detect solar axions with sensitivity sufficient to explore QCD axion models in the meV-to-eV mass range, a region inaccessible to other experiments. It will also probe dark photons, chameleons, gravitational waves, and supernova axions. IAXO's limits would be robust, independent of cosmological assumptions.
arXivarXiv · · March 31, 2025
0
An accurate solar axions ray-tracing response of BabyIAXO
S. AhyouneK. AltenmuellerI. AntolinS. BassoP. BrunF. R. CandonJ. F. CastelS. CebrianD. ChouhanR. Della CecaM. Cervera-CortesV. Chernov  +115
BabyIAXO, the intermediate stage of the International Axion Observatory (IAXO) at DESY, aims to detect solar axions via the helioscope technique. The paper presents a precise, integrated simulation of BabyIAXO's components—magnet, X-ray optics, and detectors—to calculate the detector response to the axion-photon coupling. Focusing on the Primakoff solar flux, the toolkit provides a unified framework for evaluating modifications to the helioscope and testing different axion production mechanisms.
arXivarXiv · · November 21, 2024
0
First light of BEaTriX, the new testing facility for the modular X-ray optics of the ATHENA mission
S. BassoB. SalmasoD. SpigaM. GhigoG. VecchiG. SironiV. CotroneoP. ConconiE. RedaelliA. BiancoG. PareschiG. Tagliaferri  +26
BEaTriX is a new X-ray facility at INAF-OAB Merate designed to measure the point spread function and effective area of ATHENA's silicon pore optics mirror modules before integration. It generates a broad, uniform, monochromatic, collimated beam at 4.51 keV using a micro-focus source, paraboloidal mirror, and crystal monochromator with asymmetric expansion. The beam is 170 mm × 60 mm with divergences of 1.65–3.45 arcsec. First light tests on a mirror module confirmed agreement with expectations, and the facility now operational for 30-minute characterizations.
arXivarXiv · · June 30, 2022
0
20
Physics potential of the International Axion Observatory (IAXO)
E. ArmengaudD. AttieS. BassoP. BrunN. BykovskiyJ. M. CarmonaJ. F. CastelS. CebriánM. CicoliM. CivitaniC. CogollosJ. P. Conlon  +79
The International Axion Observatory (IAXO) is a next-generation solar axion search with sensitivity to axion-like particles (ALPs) coupling to photons as low as $g_{a\gamma}\sim 10^{-12}$ GeV$^{-1}$ or to electrons $g_{ae}\sim 10^{-13}$. This enables it to detect the QCD axion in the 1 meV–1 eV range, which solves the strong CP problem, constitutes cold dark matter, and explains anomalous stellar cooling. IAXO can also probe lower-mass axions from gamma-ray transparency, soft X-ray excesses, and inflation, as well as string-theory axions relevant to dark matter and dark radiation.
arXivarXiv · · April 19, 2019
0
429
Manufacturing and testing a thin glass mirror shell with piezoelectric active control
D. SpigaM. BarberaA. ColluraS. BassoR. CandiaM. CivitaniM. Di BellaG. Di CiccaU. Lo CiceroG. LulloC.PelliciariM. Riva  +3
This paper presents a prototype thin glass mirror shell for future X-ray telescopes that integrates piezoelectric actuators for active figure correction. The mirrors are made from slumped glass foils, with commercial piezoelectric patches attached to the non-optical side. A photolithography-produced printed circuit carries the driving voltages, which are supplied by a multi-channel low-power voltage supply developed in-house. The required correction signals are determined from X-ray measurements in an intra-focal setup. The work describes the manufacturing process and the first X-ray test results.
arXivarXiv · · October 2, 2016
0
eXTP -- enhanced X-ray Timing and Polarimetry Mission
S.N. ZhangM. Feroci…S. Basso
The enhanced X-ray Timing and Polarimetry Mission (eXTP) is a planned Chinese-led space observatory for studying matter under extreme density, gravity, and magnetism. Its central contribution is a unique instrument suite that enables simultaneous spectral-timing-polarimetry observations of cosmic sources from 0.5–30 keV for the first time. The payload includes the Spectroscopic Focusing Array (total effective area ~0.9 m² at 2 keV), the Large Area Detector (~3.4 m² between 6–10 keV), the Polarimetry Focusing Array (~250 cm² at 2 keV), and the Wide Field Monitor. Launch was planned before 2025.
arXivarXiv · · July 29, 2016
0
The new SOXS instrument for the ESO NTT
P. SchipaniR. ClaudiS. CampanaA. BaruffoloS. BasaS. BassoE. CappellaroE. CasconeR. CosentinoF. DAlessioV. De CaprioM. Della Valle  +19
SOXS is a new spectroscopic facility for the ESO-NTT 3.58-m telescope that simultaneously covers the full optical/NIR band from 350 to 1750 nm with a resolution-slit product of about 4500, combining high efficiency and moderate sensitivity. The instrument also provides imaging capability in the visible band. The paper reports the current project status.
arXivarXiv · · July 13, 2016
0
56
Active shape correction of a thin glass/plastic X-ray mirror
D. SpigaM. BarberaS. BassoM. CivitaniA. ColluraS. Dell'AgostinoU. Lo CiceroG. LulloC. PelliciariM. RivaB. SalmasoL. Sciortino
This paper proposes an active shape correction method for thin glass/plastic X-ray mirrors, intended for future large-aperture telescopes. The central contribution is the concept of integrating piezoelectric actuators onto the non-optical side of slumped glass or plastic foils, with voltages driven by X-ray feedback from an intra-focal setup at the XACT facility. The aim is to correct residual deformations and improve angular resolution beyond current levels. Preliminary simulations and initial experimental steps are reported.
arXivarXiv · · October 4, 2015
0
Angular resolution measurements at SPring-8 of a hard X-ray optic for the New Hard X-ray Mission
D. SpigaL. RaimondiA. FuruzawaS. BassoR. BindaG. BorghiV. CotroneoG. GrisoniH. KuniedaF. MarioniH. MatsumotoH. Mori  +9
This paper reports hard X-ray angular resolution measurements of a multilayer-coated Wolter-I mirror shell, a demonstrator for the NHXM telescope (0.3–80 keV), performed at the SPring-8 BL20B2 beamline. To avoid finite-distance artifacts inherent in full-illumination tests of long-focal-length optics, a pencil-beam method was used, where the optic is tilted to compensate beam divergence. Reconstructed point-spread functions (PSFs) at 15–63 keV are presented and compared to PSFs computed from metrology data using Fresnel diffraction theory. The modeling accurately reproduces the measured PSFs.
arXivarXiv · · September 11, 2015
0
12
Profile reconstruction of grazing-incidence X-ray mirrors from intra-focal X-ray full imaging
D. SpigaS. BassoM. BavdazV. BurwitzM. CivitaniO. CitterioM. GhigoG. HartnerB. MenzG. PareschiL. ProserpioB. Salmaso  +2
This paper presents a method to reconstruct the surface profile of a grazing-incidence X-ray mirror from an intra-focal, full-illumination image alone, without a wavefront sensor. By placing the detector at an optimal distance from the mirror, intensity variations of the single-reflection image directly encode the mirror shape. The method is demonstrated on an intra-focal test (8 m distance) of a hot-slumped glass foil mirror prototype with a 20 m focal length, yielding a predicted imaging quality near 16 arcsec HEW.
arXivarXiv · · September 8, 2015
0
Development of mirrors made of chemically tempered glass foils for future X-ray telescopes
B. SalmasoM. CivitaniB. BrizzolariS. BassoM. GhigoG. PareschiD. SpigaL. ProserpioY. Suppiger
This paper investigates chemically tempered Gorilla glass foils as mirror substrates for future X-ray telescopes. The authors show that tempering does not degrade surface micro-roughness, but introduces stress that reduces longitudinal profile errors at scales near the mirror length. Simulations of the foil integration with reinforcing ribs indicate that this approach can meet the strength and resolution requirements of next-generation X-ray telescopes.
arXivarXiv · · February 11, 2015
0
The imaging properties of the Gas Pixel Detector as a focal plane polarimeter
S. FabianiE. Costa…S. Basso
The paper reports on the 2012 calibration of the Gas Pixel Detector (GPD) as a focal-plane photoelectric polarimeter, coupled for the first time with a JET-X optics module (3.5 m focal length, 18 arcsec resolution at 4.5 keV). This configuration was proposed for the XIPE mission. The GPD measures energy, position, arrival time, and polarization angle per photon, enabling spectro-polarimetry, timing-polarimetry, and imaging-polarimetry. The derived imaging and polarimetric performance for extended sources, such as Pulsar Wind Nebulae and Supernova Remnants, are discussed, with potential improvements from finer-resolution optics.
arXivarXiv · · March 27, 2014
0
Evaluation of the surface strength of glass plates shaped by hot slumping process
L. ProserpioS. BassoF. BorsaO. CitterioM. CivitaniM. GhigoG. PareschiB. SalmasoG. SironiD. SpigaG. TagliaferriA. D'Este  +6
This paper evaluates the mechanical strength of D263 borosilicate glass plates after hot slumping, a process used to shape X-ray telescope mirrors. Over 200 flat and bent specimens (100 mm x 100 mm, 0.4 mm thick) were tested via destructive double-ring tests. The results, analyzed with Weibull statistics and non-linear FEM, inform the survival probability of the IXO telescope design under launch loads.
arXivarXiv · · February 14, 2014
0
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
J.W. den HerderL. Piro…S. Basso
ORIGIN is a proposed ESA mission to study metal creation from the cosmic dawn using a soft X-ray observatory. Its central contribution is a high-resolution spectral imaging instrument capable of identifying physical conditions of all abundant elements between C and Ni. This instrument will be used to observe Gamma-Ray Bursts to probe metal enrichment at high redshifts (z≈10) and to study the chemical composition of galaxy clusters and the Warm-Hot Intergalactic Medium at lower redshifts via absorption lines in GRB spectra.
arXivarXiv · · April 11, 2011
0
14
Analytical computation of the off-axis Effective Area of grazing incidence X-ray mirrors
D. SpigaV. CotroneoS. BassoP. Conconi
This paper presents analytical formulas for the off-axis effective area of grazing-incidence X-ray mirrors in the double-cone approximation, replacing time-consuming ray-tracing. The method requires only an integration and standard routines to compute X-ray coating reflectivity for a given incidence angle. Algebraic expressions for the geometric area as a function of off-axis angle are provided. The analytical results are validated through comparison with a ray-tracing code.
arXivarXiv · · June 29, 2009
0
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study
G. TagliaferriS. BassoG. BorghiW. BurkertO. CitterioM. CivitaniP. ConconiV. CotroneoM. FreybergD. GaroliP. GorensteinG. Hartner  +7
Simbol-X extends grazing-incidence hard X-ray imaging up to 80 keV with a mirror module of 100 electroformed nickel shells coated with multilayer reflectors. Phase A built three engineering models (two, two, and three shells) and demonstrated that the mandrels could be fabricated with the required surface quality, a valid integration process was developed, and the produced shells achieved a half-energy width (HEW) below ∼30 arcsec at 30 keV with reasonable effective area. However, improvements are still needed to meet the full requirement of HEW <20 arcsec from 0.5 to 30 keV and a goal of 40 arcsec at 60 keV.
arXivarXiv · · March 13, 2009
0
19
Frequent collaborators
D. Spiga (13)
G. Pareschi (11)
G. Tagliaferri (8)
M. Civitani (8)
B. Salmaso (7)
V. Cotroneo (6)
V. Burwitz (5)
F. Muleri (4)
A. Rubini (4)
P. Soffitta (4)
M. Ghigo (4)
P. Conconi (4)