MCP
SB

S. Bize

34 papers in the library

Papers

30
The CIPM list "Recommended values of standard frequencies": 2021 update
H S MargolisG PanfiloG PetitC OatesT IdoS Bize
The 2021 CIPM update of recommended standard frequency values introduces a robust analysis that accounts for correlations among input data from worldwide clock comparisons, using two different algorithms for three independent calculations. This method yields unbiased frequency values with properly estimated uncertainties, producing a consistent set of frequency ratios and absolute frequencies for atomic transitions serving as secondary representations of the second. The reduced uncertainties for optical transitions increase their weight in steering International Atomic Time and are relevant for the anticipated redefinition of the second based on optical clocks.
arXivarXiv · · January 25, 2024
0
Roadmap towards the redefinition of the second
N. DimarcqM. GertsvolfG. MiletiS.BizeC.W. OatesE. PeikD. CalonicoT. IdoP. TavellaF. MeynadierG. PetitG. Panfilo  +25
This paper presents the roadmap toward redefining the SI second, updated by the CCTF Task Force in 2020. It discusses the status of optical frequency standards, their contribution to time scales and UTC, comparison methods, and the required knowledge of Earth's gravitational potential. The mandatory criteria for redefinition and their current fulfilment level are described, along with options based on a single or a set of transitions.
arXivarXiv · · July 26, 2023
0
243
Accurate laser frequency locking to optical frequency combs under low-signal-to-noise-ratio conditions
C. GuoM. FavierN. GallandV. CambierH. Álvarez-MartínezM. LoursL. De SarloM. AndiaR. Le TargatS. Bize
This paper presents a method for locking a continuous-wave laser to an optical frequency comb under low signal-to-noise ratio (SNR) conditions where other methods fail. The approach achieves accuracy typically orders of magnitude higher than conventional wavemeters and extends the usable wavelength range of a given comb. It is demonstrated on a dipole lattice trap for an optical lattice clock, showing significantly better accuracy than alternative methods in this representative case.
arXivarXiv · · March 23, 2020
0
The unit of time: present and future directions
S. Bize
This review describes the current realization of the SI second via atomic clocks achieving fractional uncertainties near $10^{-16}$ and its dissemination through International Atomic Time (TAI). It then highlights the progress in optical frequency metrology over the past two decades, which has produced optical frequency standards with fractional uncertainties of $10^{-18}$. The paper discusses ongoing efforts toward a future redefinition of the second based on these optical standards and surveys existing and emerging scientific applications of atomic frequency standards.
arXivarXiv · · October 26, 2019
0
Direct comparisons of European primary and secondary frequency standards via satellite techniques
F. RiedelA. Al-Masoudi…S. Bize
This paper reports a 26-day comparison of five optical clocks and six atomic fountain clocks located at four European metrology institutes using two satellite-based frequency comparison techniques: TWSTFT and GPS PPP. With an enhanced statistical analysis procedure that accounts for correlations and gaps, combined overall uncertainties of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for optical clock comparisons were achieved. The fountain clock comparison showed a maximum relative frequency difference of $6.9 \times 10^{-16}$ with uncertainties of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$, demonstrating direct cross-border frequency comparisons at the $10^{-16}$ level.
arXivarXiv · · October 9, 2019
0
60
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
B. M. RobertsP. DelvaA. Al-MasoudiA. Amy-KleinC. BærentsenC. F. A. BaynhamE. BenklerS. BilickiS. BizeW. BowdenJ. CalvertV. Cambier  +42
Using a European network of fiber-linked optical atomic clocks, we search for coherent variations in clock frequency comparisons to constrain transient changes in the fine structure constant $\alpha$. The analysis improves constraints, for example limiting $\alpha$ variation to $<5\times10^{-17}$ for transients of $10^3$ s duration. This also enables a search for dark matter as topological defects; no evidence is found, yielding improved constraints on couplings between dark matter and standard model particles, especially for objects larger than $\sim10^4$ km.
arXivarXiv · · July 5, 2019
0
162
First international comparison of fountain primary frequency standards via a long distance optical fiber link
J. GuénaS. WeyersM. AbgrallC. GrebingV. GerginovP. RosenbuschS. BizeB. LipphardtH. DenkerN. QuintinS. M. F. RaupachD. Nicolodi  +16
The first comparison of distant caesium fountain primary frequency standards (PFSs) via a 1415 km optical fiber link between LNE-SYRTE (Paris) and PTB (Braunschweig) is reported. The phase-coherent optical transfer achieves far better resolution than satellite links. Agreement for each pair of distant fountains is within a few $10^{-16}$, supporting the stated PFS uncertainties. A new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency is also obtained with an uncertainty of $3.1\times 10^{-16}$.
arXivarXiv · · March 2, 2017
0
Improved Tests of Lorentz Invariance in the Matter Sector using Atomic Clocks
H. Pihan-Le BarsC. GuerlinQ.G. BaileyS. BizeP. Wolf
By reanalyzing SYRTE's cesium fountain clock data with a second-order boost Lorentz transformation from the laboratory to the Sun-centered frame, the authors constrain the isotropic coefficient $\tilde{c}_{TT}$ of the $\tilde{c}_{\mu\nu}$ tensor in the minimal Standard-Model Extension. This tensor quantifies proton kinetic energy anisotropy. The new limit on $\tilde{c}_{TT}$, the least well-constrained component, improves by five orders of magnitude over the state of the art.
arXivarXiv · · January 19, 2017
0
Lorentz-symmetry test at Planck-scale suppression with nucleons in a spin-polarized 133^{133}Cs cold atom clock
H. Pihan-Le BarsC. GuerlinR.-D. LasseriJ.-P. EbranQ. G. BaileyS. BizeE. KhanP. Wolf
The authors present an improved model linking frequency shifts in a $^{133}\mathrm{Cs}$ cold atom clock to Lorentz-violating Standard-Model Extension coefficients of the proton and neutron. By using second-order Lorentz transformations and incorporating nuclear structure beyond the simpler Schmidt model, they access the isotropic coefficient $\tilde{c}_{TT}$ for both nucleons. Reanalyzing data from the FO2 fountain clock, they improve sensitivities by up to 12 orders of magnitude, reaching $10^{-20}$ GeV for neutron $\tilde{c}_{Q}$ and $10^{-13}$ GeV for neutron $\tilde{c}_{TT}$, among others.
arXivarXiv · · December 21, 2016
0
Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons
A. HeesJ. GuénaM. AbgrallS. BizeP.Wolf
Using six years of dual rubidium and caesium cold atom fountain data, the authors search for a massive scalar field dark matter candidate that would induce harmonic variations in fundamental constants. They find no such signal but provide improved constraints on the scalar's coupling to standard matter. These limits are complementary to and more than an order of magnitude stronger than prior results sensitive only to the fine structure constant.
arXivarXiv · · April 28, 2016
0
Development of a strontium optical lattice clock for the SOC mission on the ISS
S. OrigliaS. Schiller…S. Bize
This paper presents the development of a strontium optical lattice clock designed for the Space Optical Clock (SOC) mission on the ISS. The clock achieves a fractional inaccuracy goal of $5 \times 10^{-17}$ and instability below $1 \times 10^{-15} \tau^{-1/2}$, using space-compatible techniques like modular design and diode lasers. The clock transition in $^{88}$Sr was observed with a linewidth as small as 9 Hz, confirming its operational status for fundamental physics tests and relativistic geodesy.
arXivarXiv · · March 19, 2016
0
Comparing a mercury optical lattice clock with microwave and optical frequency standards
R TyumenevM FavierS BilickiE BookjansR Le TargatJ LodewyckD NicolodiY Le CoqM AbgrallJ GuénaL De SarloS Bize
This paper reports an optical lattice clock based on neutral mercury with a relative uncertainty of $1.7\times 10^{-16}$. By comparing it to a Cs atomic fountain, the absolute frequency of the $^1S_0 \rightarrow {}^3P_0$ transition of $^{199}$Hg is determined as $\nu_{\mathrm{Hg}} = 1\,128\,575\,290\,808\,154.62\,\mathrm{Hz} \pm 0.19\,\mathrm{Hz}\ (\mathrm{stat}) \pm 0.38\,\mathrm{Hz}\ (\mathrm{sys})$, limited only by the realization of the SI second. The $^{199}$Hg/$^{87}$Sr frequency ratio is measured directly as $2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times 10^{-16}$, agreeing with an independent measurement and establishing one of the few physical quantities agreed upon at this uncertainty level by different laboratories.
arXivarXiv · · March 7, 2016
0
Atomic fountains and optical clocks at SYRTE: status and perspectives
M. AbgrallB. ChupinL. De SarloJ. GuénaPh. LaurentY. Le CoqR. Le TargatJ. LodewyckM. LoursP. RosenbuschD. RoveraS. Bize
This paper reports on the work of the LNE-SYRTE atomic clock ensemble over the past decade, covering progress in atomic fountains for timekeeping and the development of optical lattice clocks based on strontium and mercury. These highly accurate clocks were used to test fundamental physical laws and to explore a future redefinition of the SI second.
arXivarXiv · · July 16, 2015
0
Development of a strontium optical lattice clock for the SOC mission on the ISS
K. BongsY. Singh…S. Bize
The SOC project aims to install a strontium optical lattice clock on the ISS by the end of the decade, improving on the ACES mission by at least an order of magnitude. A compact, modular demonstrator built during 2011–2015 targets fractional frequency instability below $1\times10^{-15}/\sqrt{\tau}$ and inaccuracy below $5\times10^{-17}$. The current status includes laser subsystems and robust preparation of cold $^{88}\mathrm{Sr}$ atoms in a second-stage magneto-optical trap.
arXivarXiv · · March 29, 2015
0
142
Testing local position and fundamental constant invariance due to periodic gravitation and boost using long-term comparison of the SYRTE atomic fountains and H-masers
M. E. TobarP. L. StanwixJ.J. McFerranJ. GuénaM. AbgrallS. BizeA. ClaironPh. LaurentP. RosenbuschD. RoveraG. Santarelli
The frequencies of Cs and Rb fountain clocks at SYRTE were compared with H-masers over eight years to search for periodic violations of local position invariance (LPI) correlated with the Earth's changing solar gravitational potential and boost relative to the CMB. A numerical derivative method reduced the impact of H-maser drifts, yielding a standard error of $4.8\times10^{-6}$ for the gravity LPI coefficient in a Cs fountain comparison and up to $10^{-11}$ for boost LPI coefficients. Combining with a cryogenic sapphire oscillator comparison, independent limits on all nine coefficients of the boost violation vector for fundamental constants were set at parts in $10^{10}$.
arXivarXiv · · June 6, 2013
0
Experimenting an optical second with strontium lattice clocks
R. Le TargatL. Lorini…S. Bize
This work demonstrates that two strontium optical lattice clocks agree within their accuracy budget at a total uncertainty of $1.6\times 10^{-16}$, and their comparison with three independent caesium fountain clocks yields a reproducibility limited only at $3.1\times 10^{-16}$ by the best microwave realizations of the SI second. These results show that optical clocks have surpassed the caesium fountains used to define the second, providing a key step toward a redefinition of the unit of time.
arXivarXiv · · January 25, 2013
0
Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock
J. GuénaP. RosenbuschPh. LaurentM. AbgrallD. RoveraM. LoursG. SantarelliM. E. TobarS. BizeA. Clairon
We report the operation of a dual alkali atomic fountain clock that simultaneously cools, launches, and detects 133Cs and 87Rb atoms in LNE-SYRTE's FO2 double fountain without degradation of stability or accuracy. The first Rb/Cs frequency measurement campaign in this configuration yields a new determination of the absolute 87Rb hyperfine frequency.
arXivarXiv · · January 3, 2013
0
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
S. SchillerA. Görlitz…S. Bize
The Space Optical Clocks (SOC) project aims to install an optical lattice clock on the ISS, improving upon the ACES mission by at least one order of magnitude. As a precursor, the EU-funded SOC2 project (2011-2015) develops two transportable lattice optical clock demonstrators based on trapped neutral ytterbium and strontium atoms. These achieve a relative frequency instability below $1\times10^{-15}$ at 1 s and inaccuracy below $5\times10^{-17}$, representing improvements of about two and one orders over today's best transportable clocks. This paper presents the first year's results.
arXivarXiv · · June 17, 2012
0
49
Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
J. J. McFerranD. V. MagalhaesC. MandacheJ. MilloW. ZhangY. Le CoqG. SantarelliS. Bize
By trapping Hg atoms in an optical lattice in the Lamb-Dicke regime, the authors obtain a sub-15 Hz spectral line at 265.6 nm and lock an ultrastable laser to this clock transition. The locked laser achieves a fractional frequency instability of $5.4\times 10^{-15}/\sqrt{\tau}$ for $\tau\leq 400$ s. The probe light is derived from a 1062.6 nm fiber laser stabilized to a cavity with a mean drift of $-6.0\times 10^{-17}$ s$^{-1}$ over five months.
arXivarXiv · · May 18, 2012
0
Feshbach resonances in Cesium at Ultra-low Static Magnetic Fields
D. J. PapoularS. BizeA. ClaironH. MarionS. J. KokkelmansG. V. Shlyapnikov
Using an atomic fountain clock, the authors observed Feshbach resonances in $^{133}$Cs atoms at ultra-low static magnetic fields for two hyperfine states. The high sensitivity allowed measurements at densities of $2\times10^7$ cm$^{-3}$ with high signal-to-noise ratio. The resonances were reproduced by coupled-channels calculations in excellent agreement with the data. The authors identify them as s-wave resonances involving weakly-bound triplet states, identify the resonant closed channels, and explain the multi-peak structure. A model accounting for collisional processes in the fountain explains the asymmetric resonance shape in the kinetic-energy-dominated regime.
arXivarXiv · · May 11, 2012
0
A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty
J. J. McFerranL. YiS. MejriS. Di MannoW. ZhangJ. GuénaY. Le CoqS. Bize
This paper reports a measurement of the $(6s^2)^1S_0 \to (6s7s)^3P_0$ clock transition in $^{199}$Hg with a fractional uncertainty of $5.7\times10^{-15}$, an improvement of nearly three orders of magnitude. The atoms are trapped in a vertical lattice at the newly determined magic wavelength $362.5697\pm0.0011$ nm. A Rabi pulse of 80 ms at 265.6 nm yields an atomic quality factor $Q \approx 10^{14}$, and only three laser wavelengths are used for the entire sequence.
arXivarXiv · · January 17, 2012
0
1
An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
S.T. DawkinsR. ChicireanuM. PetersenJ. MilloD.V. MagalhãesC. MandacheY. Le CoqS. Bize
The paper presents an ultra-stable deep-UV interrogation source for a mercury optical lattice clock. A Fabry-Pérot cavity with fused-silica mirrors (low thermal noise) stabilizes a 1062.6 nm fiber laser. The signal is referenced to primary frequency standards via an optical frequency comb, achieving fractional stability at the 1E-15 level. After two frequency-doubling stages, several milliwatts at 265.6 nm are obtained for clock interrogation.
arXivarXiv · · March 22, 2010
0
Ultrastable lasers based on vibration insensitive cavities
J. MilloD. V. MagalhaesC. MandacheY. Le CoqE. M. L. EnglishP. G. WestergaardJ. LodewyckS. BizeP. LemondeG. Santarelli
The paper presents two ultrastable lasers built from vibration-insensitive cavities, one with vertical and one with horizontal optical axis. Using fused silica mirror substrates reduces the thermal noise limit, improving frequency stability. Vibration sensitivity in each spatial direction is at or below $1.5 \times 10^{-11}$ per $\text{m} \cdot \text{s}^{-2}$, and the design eliminates fine-tuning of support points. One laser achieves a relative frequency stability better than $5.6 \times 10^{-16}$ at 1 second, the best reported for this cavity length.
arXivarXiv · · January 29, 2009
0
312
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
J. MilloM. AbgrallM. LoursE.M.L. EnglishH. JiangJ. GuenaA. ClaironS. BizeY. Le CoqG. SantarelliM.E. Tobar
The authors generate a low-noise microwave reference by locking a fiber-based femtosecond laser to an ultra-stable optical cavity. The system achieves stability of about $3\times10^{-15}$ from 1 s to 10 s, comparable to a cryogenic sapphire oscillator (CSO) and a Ti:Sapphire comb. Applied to Ramsey spectroscopy in a cesium fountain clock, it yields a stability of $3.5\times10^{-14}\tau^{-1/2}$. The continuously operated fiber setup thus shows potential to replace the CSO in high-stability atomic clocks.
arXivarXiv · · January 23, 2009
0
Doppler-free spectroscopy of the 1S0-3P0 optical clock transition in laser-cooled fermionic isotopes of neutral mercury
M. PetersenR. ChicireanuS.T. DawkinsD.V. MagalhãesC. MandacheY. LecoqA. ClaironS. Bize
We report the first direct laser spectroscopy of the $^1$S$_0$-$^3$P$_0$ optical clock transition at 265.6 nm in laser-cooled fermionic isotopes of neutral mercury. The Doppler-free recoil doublet is resolved by measuring trap depletion from excited $^3$P$_0$ atoms. Absolute frequencies are measured as $1128575290808 \pm 5.6$ kHz for $^{199}$Hg and $1128569561140 \pm 5.3$ kHz for $^{201}$Hg, improving precision by over four orders of magnitude over prior indirect determinations. Mercury's low blackbody radiation sensitivity makes it a promising candidate for optical lattice clocks.
arXivarXiv · · July 22, 2008
0
Interference-filter-stabilized external-cavity diode lasers
X. BaillardA. GauguetS. BizeP. LemondePh. LaurentA. ClaironP. Rosenbusch
This paper presents an external-cavity diode laser design in which a low-loss interference filter replaces the usual diffraction grating for wavelength selection. The filter enables a linear cavity that reduces sensitivity to misalignment and decouples feedback from tuning, allowing independent optimization of each. The design is demonstrated at 698, 780, and 852 nm and is proposed as suitable for space-borne lasers.
arXivarXiv · · May 5, 2006
0
418
Cold atom Clocks and Applications
S. BizeP. LaurentM. AbgrallH. MarionI. MaksimovicL. CacciapuotiJ. GruenertC. VianF. Pereira dos SantosP. RosenbuschP. LemondeG. Santarelli  +5
This paper reports advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. By employing a cryogenic sapphire oscillator as an ultra-stable local reference, the $^{133}$Cs and $^{87}$Rb atomic fountains achieve a frequency instability of $1.6\times 10^{-14}\tau^{-1/2}$. A method to control the cold-collision shift further improves stability to $2\times 10^{-16}$ at $50,000$ s, and the clocks realize the SI second with an accuracy of $7\times 10^{-16}$, an order of magnitude better than uncooled devices. The paper also describes tests of fundamental constant variations using these fountains and updates on the PHARAO space clock for the ACES/ESA mission.
arXivarXiv · · February 22, 2005
0
New Limits to the Drift of Fundamental Constants from Laboratory Measurements
M. FischerN. KolachevskyM. ZimmermannR. HolzwarthTh. UdemT.W. HaenschM. AbgrallJ. GruenertI. MaksimovicS. BizeH. MarionF.Pereira Dos Santos  +8
The authors remeasured the absolute 1S-2S transition frequency in atomic hydrogen and compared it to a 1999 measurement, finding a drift of $(-29\pm 57)$ Hz relative to the Cs hyperfine splitting. Combining this with optical Hg$^+$ and microwave Rb-Cs clock data, they deduce separate limits: $\dot{\alpha}/\alpha = (-0.9\pm 2.9)\times 10^{-15}$ yr$^{-1}$ and a fractional time variation of the Rb/Cs nuclear magnetic moment ratio of $(-0.5 \pm 1.7)\times 10^{-15}$ yr$^{-1}$, the latter constraining strong-interaction constancy.
arXivarXiv · · December 12, 2003
0
Precision Spectroscopy of Atomic Hydrogen and Variations of Fundamental Constants
M. FischerN.KolachevskyM. ZimmermannR. HolzwarthTh. UdemT.W. HänschM. AbgrallJ. GrünertI. MaksimovicS. BizeH. MarionF. Pereira Dos Santos  +5
A 2003 measurement of the 1S–2S two-photon transition frequency in atomic hydrogen, combined with published optical clock data for $^{199}\mathrm{Hg}^+$ and a $^{87}\mathrm{Rb}$–$^{133}\mathrm{Cs}$ comparison, yields the first model-independent bound on the present-day fractional time variation of the fine-structure constant: $\partial/\partial t (\ln \alpha) = (-0.9 \pm 4.2) \times 10^{-15}\,\mathrm{yr}^{-1}$. The result does not assume any relation between drifts of electromagnetic, strong, or weak coupling constants. A corresponding limit on the ratio of $^{87}\mathrm{Rb}$ and $^{133}\mathrm{Cs}$ nuclear magnetic moments is also given.
arXivarXiv · · November 26, 2003
0
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
P. WolfS. BizeA. ClaironA.N. LuitenG. SantarelliM.E. Tobar
By comparing a cryogenic sapphire oscillator with a hydrogen maser, this work sets new constraints on Lorentz invariance violation. The oscillator frequency's orientation and velocity dependence yields limits on the Mansouri–Sexl parameters: $\delta - \beta + 1/2 \leq 3.4 \times 10^{-9}$ (Michelson–Morley test) and $\beta - \alpha - 1 \leq 4.1 \times 10^{-7}$ (Kennedy–Thorndike test). The latter represents a 50-fold improvement over the best previous result, and both improve the authors' 2003 limits by about a factor of two.
arXivarXiv · · June 11, 2003
0
Frequent collaborators
A. Clairon (14)
G. Santarelli (13)
M. Abgrall (12)
J. Lodewyck (9)
R. Le Targat (8)
Y. Le Coq (8)
J. Guéna (7)
P. Rosenbusch (7)
P. Lemonde (7)
H. Marion (7)
M. Lours (6)
C. Mandache (6)