MCP
SM

S. Merlet

10 papers in the library

Papers

10
Technologies for the ELGAR large scale atom interferometer array
B. CanuelS. Abend…S. Merlet
The ELGAR array of atom gradiometers is proposed to observe gravitational waves in the infrasound band, targeting a peak strain sensitivity of $3.3 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz. This paper details the main technological bricks required for its realization, including site options, atom optics, source requirements, seismic isolation, gravity gradient noise reduction, and metrology of noise couplings. The research pathways for each component are emphasized.
arXivarXiv · · July 8, 2020
0
30
Impact of direct digital synthesizer finite resolution on atom gravimeters
R KarcherFranck Pereira dos SantosS Merlet
This paper studies how the finite resolution of a direct digital synthesizer (DDS) chirp rate biases gravity measurements in free-fall atom gravimeters. The chirp compensates the gravitational phase shift, but DDS time and frequency resolution introduces a systematic bias that can degrade accuracy. The authors show that choosing chirp parameters to balance interferometer phase resolution against this bias mitigates the effect.
arXivarXiv · · January 21, 2020
0
ELGAR -- a European Laboratory for Gravitation and Atom-interferometric Research
B. CanuelS. Abend…S. Merlet
ELGAR is a proposed underground infrastructure that uses atom interferometry to detect gravitational waves in the infrasound band (0.1–10 Hz), a frequency range not covered by LISA or third-generation ground-based detectors. Based on advances in atomic physics, its design targets a peak strain sensitivity of $4.1 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz, enabling multi-band GW astronomy and also supporting research in gravitation, general relativity, and geology.
arXivarXiv · · November 9, 2019
0
203
Simultaneous accurate determination of both gravity and its vertical gradient
R. CaldaniK WengS. MerletFranck Pereira dos Santos
We present a method for simultaneously measuring gravity acceleration and its vertical gradient with a dual atom interferometer, free from uncertainty related to the positions of the two atomic samples. The method uses a dual lock technique that simultaneously adjusts the chirp rate applied to the laser frequency difference to compensate gravity acceleration, and the frequency jump at the mid pulse to compensate the gravity gradient. Both quantities are determined in terms of frequencies.
arXivarXiv · · December 21, 2018
0
Improving the accuracy of atom interferometers with ultracold sources
R KarcherA ImanalievS. MerletFranck Pereira dos Santos
By employing ultracold atoms (50 nK) in an atom gravimeter, this work achieves gravity measurements with 10 nm/s² statistical uncertainty and characterizes the limiting systematic effect of wavefront aberrations in light beam splitters. A model is developed for this effect, and a correction method based on extrapolating measurements to zero temperature yields a 13 nm/s² uncertainty, demonstrating that ultracold sources enable record-breaking accuracy for atom-interferometer inertial sensors.
arXivarXiv · · April 13, 2018
0
Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors
M. LangloisR. CaldaniA. TrimecheS. MerletFranck Pereira dos Santos
The authors experimentally demonstrate a method to extract the differential phase between two simultaneous atom interferometers. Using one magneto-optical trap, they produce two vertically separated, synchronously free-falling atomic sources via an accelerated lattice. By correlating each interferometer’s signal with a seismometer’s vibration measurement, they extract the phase of each interferometer. This yields vibration-noise-free differential phase sensitivity limited only by detection noise when the interferometers are in phase.
arXivarXiv · · December 6, 2017
0
Influence of chirping the Raman lasers in an atom gravimeter: phase shifts due to the Raman light shift and to the finite speed of light
B. ChengP. GillotS. MerletF. Pereira Dos Santos
This paper analyzes how the frequency chirp applied to Raman lasers in an atom gravimeter biases the gravity measurement. The authors show that chirping only one of the two lasers changes the Raman light shift, causing a bias of a fraction of $\mu$Gal. This effect is not canceled by averaging over the two directions of the Raman wavevector $k$, thus limiting the rejection efficiency of the $k$-reversal technique. The analysis separates this bias from the finite-speed-of-light effect, which is found to be consistent with expectations. The study highlights the benefit of chirping both lasers symmetrically.
arXivarXiv · · June 10, 2015
0
Perturbations of the local gravity field due to mass distribution on precise measuring instruments: a numerical method applied to a cold atom gravimeter
G. D'AgostinoS. MerletA. LandraginF. Pereira Dos Santos
This paper presents a numerical method, based on a finite-element simulation, that computes the gravitational field generated by objects of arbitrary geometry and density. Applied to an absolute cold atom gravimeter targeting a $10^{-9}$ relative uncertainty, the method quantifies the self-gravity perturbation of the instrument. The resulting bias is $(1.3 \pm 0.1) \times 10^{-9}$ of Earth's gravitational field, determined through a perturbative treatment.
arXivarXiv · · May 11, 2011
0
Comparison of 3 absolute gravimeters based on different methods for the e-MASS project
A. Louchet-ChauvetS. MerletQ. BodartA. LandraginF. Pereira Dos SantosH. BaumannG. D'AgostinoC. Origlia
A comparison of three absolute gravimeters (FG5#209, IMGC-02, and CAG) relying on optical and atomic interferometry methods was conducted at LNE in April 2010 for the e-MASS project. The instruments' gravitational acceleration measurements were compared at four points on the same pillar, aiming toward an absolute determination of $g$ for a watt balance experiment.
arXivarXiv · · August 17, 2010
0
Comparison between two mobile absolute gravimeters: optical versus atomic interferometers
S. MerletQ. BodartN. MalossiA. LandraginF. Pereira Dos SantosO. GitleinL. Timmen
This paper reports a direct comparison of two mobile absolute gravimeters: the LNE-SYRTE cold-atom interferometer and the Hannover FG5#220 optical interferometer. Both instruments participated in the 2009 International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. A subsequent bilateral comparison in the LNE watt balance laboratory found agreement between the two devices at $4.3 \pm 6.4$ $\mu$Gal, demonstrating that atomic and optical interferometry can achieve consistent gravity measurements when both instruments are movable.
arXivarXiv · · May 3, 2010
0
183
Frequent collaborators
A. Landragin (5)
Franck Pereira dos Santos (4)
F. Pereira Dos Santos (4)
B. Canuel (2)
S. Abend (2)
P. Amaro-Seoane (2)
F. Badaracco (2)
Q. Beaufils (2)
A. Bertoldi (2)
K. Bongs (2)
P. Bouyer (2)
C. Braxmaier (2)