This paper presents the design and initial measurements of dual-polarization lumped element kinetic inductance detectors (LEKIDs) for CMB observations. The horn-coupled arrays consist of 20 elements (40 LEKIDs) from thin-film aluminum, optimized for 150 GHz, fabricated on either 160-micron silicon or 30-micron SOI wafers. Characterization with a linearly-polarized electronic source and a thermal source yielded noise spectra, noise-equivalent temperature, and responsivity, establishing the detectors' baseline performance.