MCP
SC

SuperCDMS Collaboration

15 papers in the library

Papers

15
Low Frequency Noise Identification for the SuperCDMS Experiment using Convolutional Neural Networks
SuperCDMS collaborationM. F. AlbakryI. AlkhatibD. Alonso-GonzálezJ. AnczarskiT. AralisT. AramakiA. Ashtari EsfahaniI. Ataee LangroudyR. BhattacharyyaP. L. BrinkM. Buchanan  +115
This paper presents a convolutional neural network (CNN) method to identify low-frequency noise (LFN) in SuperCDMS data. LFN resembles low-energy signal pulses and is hard to remove; the prior CDMSlite Run 3 event-selection criterion reduced sensitivity to low-mass dark matter. The CNN-based rejection aims to improve signal efficiency while maintaining purity. Applied to the CDMSlite Run 3 dataset, its impact on dark matter sensitivities is reported and further examined through case studies.
arXivarXiv · · October 30, 2026
0
Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector
SuperCDMS CollaborationM.F. AlbakryI. AlkhatibD. Alonso-GonzálezJ. AnczarskiT. AralisT. AramakiI. Ataee LangroudyC. BathurstR. BhattacharyyaA.J. BifflP.L. Brink  +181
Using a SuperCDMS HVeV detector, a blind analysis of 6.1 g·days of underground exposure produced exclusion limits on dark matter-electron scattering for masses down to 1 MeV/c², and on absorption processes (photon–dark photon mixing, axionlike particle–electron coupling) for particles above 1.2 eV/c². The result improves on previous HVeV limits by reducing luminescence from the detector holder's printed circuit boards.
arXivarXiv · · September 3, 2025
1
17
Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps
SuperCDMS CollaborationM. F. AlbakryI. AlkhatibD. Alonso-GonźalezD. W. P. AmaralJ. AnczarskiT. AralisT. AramakiI. Ataee LangroudyC. BathurstR. BhattacharyyaA. J. Biffl  +139
The SuperCDMS HVeV collaboration demonstrates a sub-keV calibration method for cryogenic silicon calorimeters using Compton steps from gamma-ray scattering. Applied to four detectors operated at 0 V bias, the calibration reveals the detector response is about 30% weaker than expected relative to the established high-voltage optical-photon calibration, indicating challenges in modeling low-mass dark matter searches.
arXivarXiv · · August 4, 2025
0
6
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
SuperCDMS CollaborationM.F. AlbakryI. AlkhatibD. Alonso-GonzálezD.W.P. AmaralJ. AnczarskiT. AralisT. AramakiI.J. ArnquistI. Ataee LangroudyE. AzadbakhtC. Bathurst  +130
This paper reports dark-matter-electron interaction constraints from the first underground run of multiple SuperCDMS HVeV detectors in the same housing. Using 7.63 g-days of exposure, it sets upper limits on the scattering cross section for dark matter masses 0.5–1000 MeV/$c^2$ and on dark photon and axion-like particle couplings for masses 1.2–23.3 eV/$c^2$. The 225 m water-equivalent overburden, anticoincidence selection, and improved pile-up rejection enhance sensitivity; for heavy-mediator scattering, the cross-section limit improves by up to a factor of 25 over a previous search.
arXivarXiv · · July 10, 2024
0
58
Effective Field Theory Analysis of CDMSlite Run 2 Data
SuperCDMS CollaborationM.F. AlbakryI. AlkhatibD.W.P. AmaralT. AralisT. AramakiI.J. ArnquistI. Ataee LangroudyE. AzadbakhtS. BanikC. BathurstD.A. Bauer  +118
An effective field theory (EFT) analysis of CDMSlite Run 2 data, which used a 600 g Ge detector in high-voltage mode to search for low-mass WIMPs (2–20 GeV/$c^2$), is presented. A binned likelihood Bayesian analysis performed on an extended energy range, with 5σ cuts around activation peaks, found the data consistent with background-only models. No additional EFT interaction was supported. Upper limits on WIMP mass and coupling-coefficient amplitudes and phases are given for each operator, improving previous bounds for WIMP masses above 5 GeV/$c^2$.
arXivarXiv · · May 24, 2022
0
4
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
SuperCDMS CollaborationM.F. AlbakryI. AlkhatibD.W.P. AmaralT. AralisT. AramakiI.J. ArnquistI. Ataee LangroudyE. AzadbakhtS. BanikC. BathurstD.A. Bauer  +117
Operating a 1-gram silicon SuperCDMS-HVeV detector at 0 V, 60 V, and 100 V bias, this work observes an excess of events in the tens of eV region at 0 V. By comparing datasets, the dominant source of this excess is attributed to luminescence from the printed circuit boards in the detector holder. Despite the excess, the 0 V data set a competitive exclusion limit on spin-independent dark matter–nucleon elastic scattering for masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by a very low $\mathcal{O}(10)$ eV nuclear recoil threshold.
arXivarXiv · · April 17, 2022
0
47
Constraints on Lightly Ionizing Particles from CDMSlite
SuperCDMS CollaborationI. AlkhatibD.W.P. AmaralT. AralisT. AramakiI.J. ArnquistI. Ataee LangroudyE. AzadbakhtS. BanikD. BarkerC. BathurstD.A. Bauer  +106
Using the CDMSlite germanium detector, the Cryogenic Dark Matter Search set first direct-detection limits on the vertical intensity of cosmogenically produced lightly ionizing particles (LIPs) with charge below $e/(3\times10^5)$ and the strongest limits for charge $\leq e/160$, achieving a minimum intensity of $1.36\times10^{-7}\,\text{cm}^{-2}\text{s}^{-1}\text{sr}^{-1}$ at $e/160$. These results span LIP masses from 5 MeV/$c^2$ to 100 TeV/$c^2$ and $\beta\gamma$ values from 0.1 to $10^6$, excluding non-relativistic LIPs with $\beta\gamma$ as low as 0.1 for the first time.
arXivarXiv · · November 18, 2020
0
18
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS CollaborationD.W. AmaralT. AralisT. AramakiI.J. ArnquistE. AzadbakhtS. BanikD. BarkerC. BathurstD.A. BauerL.V.S. BezerraR. Bhattacharyya  +107
Using a 0.93 g SuperCDMS Si detector with a 3 eV phonon energy resolution and a charge resolution of 3% of a single electron-hole pair at 100 V bias, this paper reports constraints on light dark matter from a blind analysis of 1.2 gram-days of exposure acquired above ground. Incorporating charge carrier trapping and impact ionization into signal models, the dark matter-electron cross section $\bar{\sigma}_{e}$ is constrained for masses 0.5--$10^4$ MeV$/c^2$, with a minimum 90% confidence-level upper limit of $8.7\times10^{-34}$ cm$^2$. For dark photon kinetic mixing parameter $\varepsilon$ and axioelectric coupling $g_{ae}$, limits are set for masses 1.2--50 eV$/c^2$, reaching $3.3\times10^{-14}$ and $1.0\times10^{-9}$, respectively.
arXivarXiv · · May 28, 2020
0
277
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
SuperCDMS CollaborationT. AralisT. AramakiI.J. ArnquistE. AzadbakhtW. BakerS. BanikD. BarkerC. BathurstD.A. BauerL.V.S BezerraR. Bhattacharyya  +95
Using electron recoil data from cryogenic germanium detectors in the SuperCDMS Soudan experiment, new exclusion limits are set on two dark-matter candidates: the kinetic mixing parameter of dark photons and the axioelectric coupling of axion-like particles, assuming each constitutes all galactic dark matter. The constraints cover masses from 40 eV/$c^2$ to 500 eV/$c^2$, reaching below $10^{-15}$ for dark-photon mixing near 100 eV/$c^2$ and below $10^{-12}$ for axion-like coupling at a few hundred eV/$c^2$, thereby excluding previously untested parameter space below ~1 keV/$c^2$.
arXivarXiv · · November 27, 2019
0
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
SuperCDMS CollaborationR. AgneseT. AralisT. AramakiI.J. ArnquistE. AzadbakhtW. BakerS. BanikD. BarkerD.A. BauerT. BinderM.A. Bowles  +91
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) presents a profile-likelihood analysis of its final dataset, using a different detector than in previous runs. With an energy threshold of 70 eV and improved noise discrimination and background modeling, the experiment reports significantly enhanced sensitivity to dark matter particles with masses between 2.5 and 10 GeV/c$^2$. It sets an upper limit on the spin-independent dark matter-nucleon scattering cross section in germanium of $5.4 \times 10^{-42} \ \text{cm}^2$ at 5 GeV/c$^2$, a factor of approximately 2.5 improvement over the previous CDMSlite result.
arXivarXiv · · August 28, 2018
0
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
SuperCDMS CollaborationR. AgneseT. AralisT. AramakiI.J. ArnquistE. AzadbakhtW. BakerS. BanikD. BarkerD.A. BauerT. BinderM.A. Bowles  +90
Using a 0.93 gram SuperCDMS HVeV detector with a charge resolution of 0.1 electron-hole pairs, we set the first limits on inelastic electron-scattering dark matter and dark photon absorption from a single-charge-sensitive device. These constraints improve the sensitivity to dark matter particles down to 1 MeV/c², and achieve competitive dark photon limits with only 0.49 gram days of exposure, demonstrating the power of phonon-mediated detectors sensitive to single electronic excitations.
arXivarXiv · · April 27, 2018
0
462
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
SuperCDMS CollaborationR. AgneseT. AramakiI.J. ArnquistW. BakerD. BalakishiyevaS. BanikD. BarkerR. Basu ThakurD.A. BauerT. BinderM.A. Bowles  +92
The SuperCDMS experiment at Soudan reports a blind search for WIMPs using 1690 kg·days of germanium data. One candidate event was observed, consistent with expected backgrounds. Combined with previous Ge results, this sets an upper limit on the spin-independent WIMP–nucleon cross section of $1.4 \times 10^{-44}$ cm$^2$ at 46 GeV/$c^2$, which is the strongest limit for WIMP–germanium-nucleus interactions for masses above 12 GeV/$c^2$.
arXivarXiv · · August 29, 2017
0
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS CollaborationR. AgneseA.J. AndersonT. AralisT. AramakiI.J. ArnquistW. BakerD. BalakishiyevaD. BarkerR. Basu ThakurD.A. BauerT. Binder  +96
The CDMSlite mode of the SuperCDMS experiment applies a high detector-bias voltage to amplify phonon signals from drifting charges, achieving an energy threshold as low as 56 eV$_{\text{ee}}$. Detailed noise studies, electric-field geometry corrections, and a fiducial parameter eliminate poorly measured events, yielding an energy resolution from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. Accounting for astrophysical uncertainties in the WIMP velocity distribution, new spin-dependent limits exclude parameter space for WIMP masses $\lesssim$3 GeV/$c^2$.
arXivarXiv · · July 6, 2017
0
379
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS CollaborationR. AgneseA.J. AndersonT. AramakiM. AsaiW. BakerD. BalakishiyevaD. BarkerR. Basu ThakurD.A. BauerJ. BillardA. Borgland  +78
The CDMSlite experiment uses cryogenic germanium detectors with high bias voltage to amplify phonon signals for low-mass WIMP searches. The second run achieved a 56 eV electron-recoil energy threshold with 70 kg·days exposure. A fiducialization cut reduced backgrounds below previous levels, enabling the exclusion of new WIMP-nucleon spin-independent cross-section parameter space for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
arXivarXiv · · September 8, 2015
0
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS CollaborationR. AgneseA.J. AndersonD. BalakishiyevaR. Basu ThakurD.A. BauerJ. BillardA. BorglandM.A. BowlesD. BrandtP.L. BrinkR. Bunker  +75
A maximum likelihood analysis of low-energy CDMS II germanium data builds a background model (GEANT4 for surface events from $^{210}$Pb decay, calibration data for gamma background) and finds no statistically significant WIMP component. Fitting an analytic background model proposed by Collar and Fields, which previously claimed a large signal-like excess, confirms a strong preference for a signal hypothesis under those assumptions. However, excesses appear in both single- and multiple-scatter events, indicating the signal stems from an inadequate background model rather than WIMPs.
arXivarXiv · · October 4, 2014
0
23
Frequent collaborators
R. Bunker (15)
B. Cabrera (15)
J. Cooley (15)
P. Cushman (15)
E. Figueroa-Feliciano (15)
L. Hsu (15)
R. Mahapatra (15)
N. Mirabolfathi (15)
R. Partridge (15)
M. Pyle (15)
W. Rau (15)
B. Sadoulet (15)