MCP
TB

T. Bergmann

23 papers in the library

Papers

23
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
M. AkerK. AltenmüllerM. ArenzM. BabutzkaJ. BarrettS. BauerM. BeckA. BeglarianJ. BehrensT. BergmannU. BessererK. Blaum  +196
The KATRIN experiment's first four-week science run in spring 2019 measured the tritium beta-decay electron spectrum near the 18.57 keV endpoint using a MAC-E filter, yielding an effective neutrino mass square of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. This result sets an upper limit of 1.1 eV (90% confidence) on the absolute neutrino mass, matching the experimental sensitivity. The limit improves previous kinematic bounds by nearly a factor of two and offers a model-independent input for cosmology.
arXivarXiv · · September 13, 2019
0
High-resolution spectroscopy of gaseous 83m^\mathrm{83m}Kr conversion electrons with the KATRIN experiment
K. AltenmüllerM. ArenzW.-J. BaekM. BeckA. BeglarianJ. BehrensT. BergmannA. BerlevU. BessererK. BlaumF. BlockS. Bobien  +115
For the first time, the KATRIN experiment has measured conversion electrons from the decay of gaseous metastable $^{83\mathrm{m}}$Kr. This calibration run demonstrates the functionality of the full KATRIN beamline and is a major commissioning milestone for the upcoming neutrino mass measurement. The main spectrometer's excellent energy resolution of approximately 1 eV allowed the determination of the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of about 1%.
arXivarXiv · · March 15, 2019
0
The KATRIN Superconducting Magnets: Overview and First Performance Results
M. ArenzW.-J. BaekM. BeckA. BeglarianJ. BehrensT. BergmannA. BerlevU. BessererK. BlaumT. BodeB. BornscheinL. Bornschein  +112
The KATRIN experiment aims to determine the effective electron anti-neutrino mass with sub-eV sensitivity. This paper reports first performance results of the superconducting magnet chain that generates adiabatic fields up to 6 T guiding β-electrons within a 191 Tcm² flux. The entire 70-m-long beam-line magnet system was operated for weeks at 70% of design fields. Source magnetic field stability was better than 0.01% per month, and magnet safety systems were successfully tested.
arXivarXiv · · June 21, 2018
0
38
Muon-induced background in the KATRIN main spectrometer
K. AltenmüllerM. ArenzW.-J. BaekM. BeckA. BeglarianJ. BehrensT. BergmannA. BerlevU. BessererK. BlaumS. BobienT. Bode  +122
The KATRIN experiment, measuring the electron antineutrino mass with 0.2 eV/c² sensitivity, faces muon-induced backgrounds in its above-ground main spectrometer (MS). Coincidence measurements with a muon detector showed that about 12% of secondary electrons emitted from the inner MS surface are induced by cosmic-ray muons, with roughly one secondary electron per 17 muon crossings. However, the MS's magnetic and electrostatic shielding efficiently suppresses these electrons, and muons contribute less than 17% (90% confidence) of the total MS background.
arXivarXiv · · May 30, 2018
0
28
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
KATRIN CollaborationM. ArenzW.-J. BaekS. BauerM. BeckA. BeglarianJ. BehrensR. BerendesT. BergmannA. BerlevU. BessererK. Blaum  +118
The KATRIN experiment measures the electron neutrino mass via tritium beta-decay endpoint spectroscopy. A major background originates from short-lived radon isotopes inside the spectrometer. The magnetic pulse method reduces this background by briefly lowering the magnetic guiding field, which removes stored electrons. Its working principle is described, and commissioning measurements demonstrate its effectiveness. Simulations with Kassiopeia provide insight into electron storage and removal dynamics.
arXivarXiv · · May 3, 2018
0
12
First transmission of electrons and ions through the KATRIN beamline
M. ArenzW.-J. BaekM. BeckA. BeglarianJ. BehrensT. BergmannA. BerlevU. BessererK. BlaumT. BodeB. BornscheinL. Bornschein  +117
The KATRIN experiment, designed to measure the neutrino mass with 0.2 eV sensitivity, reports commissioning milestones: first transmission of electrons and ions through its fully assembled beamline. During the 2016 First Light campaign, photoelectrons from the rear wall and ions from a dedicated source were transmitted; in 2017, gaseous and condensed Kr-83m sources were used. Results demonstrate stable transmission from all sources and initial characterization of system performance.
arXivarXiv · · February 12, 2018
0
64
Performance of the EDELWEISS-III experiment for direct dark matter searches
E. ArmengaudQ. ArnaudC. AugierA. BenoîtL. BergéT. BergmannJ. BillardT. de BoissièreG. BresA. BroniatowskiV. BrudaninP. Camus  +51
The paper reports performance results of the EDELWEISS-III experiment, which uses cryogenic germanium detectors with a Fully Inter-Digitized (FID) design to search for WIMP dark matter. The key achievement is the demonstrated rejection of surface $\alpha$ and $\beta$ decays ($R_{\rm surf} < 4 \times 10^{-5}$ per $\alpha$ at 90% C.L.) and bulk $\gamma$-ray events ($R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.) through simultaneous heat and ionization measurements. The 24 FID detectors achieve baseline resolutions below 0.7 keV$_{ee}$ (FWHM) for fiducial ionization energy and below 1.5 keV$_{ee}$ for heat energy, with a fiducial volume fraction of $(74.6 \pm 0.4)\%$.
arXivarXiv · · June 4, 2017
0
165
Development of 100^{100}Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
E. ArmengaudC. AugierA.S. BarabashJ.W. BeemanT.B. BekkerF. BelliniA. BenoîtL. BergéT. BergmannJ. BillardR.S. BoikoA. Broniatowski  +90
This paper reports the development of $^{100}$Mo-enriched scintillating bolometers for the CUPID neutrinoless double-beta decay search. The detectors achieve 4–6 keV FWHM energy resolution near the 3034 keV $Q$-value, >8$\sigma$ rejection of $\alpha$-induced background above 2.6 MeV, and crystal radiopurity <10 $\mu$Bq/kg for $^{232}$Th and $^{226}$Ra. Using only 10 kg$\times$d exposure, the two-neutrino double-beta decay half-life of $^{100}$Mo was measured with the highest accuracy to date: $T_{1/2}=[6.90\pm0.15(\text{stat.})\pm0.37(\text{syst.})]\times10^{18}$ yr. Lithium molybdate was selected for the CUPID-0/Mo demonstrator.
arXivarXiv · · April 6, 2017
0
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS CollaborationE. ArmengaudQ. ArnaudC. AugierA. BenoîtL. BergéT. BergmannJ. BillardJ. BlümerT. de BoissièreG. BresA. Broniatowski  +54
Using a 582 kg-day fiducial exposure of 800 g Germanium bolometers with interleaved electrodes, the EDELWEISS-III experiment searched for galactic dark matter WIMPs in the 4–30 GeV/$c^2$ mass range. For 5 (20) GeV/$c^2$ WIMPs, 9 (4) events were observed against an expected background of 6.1 (1.4), yielding a 90% CL spin-independent cross-section limit of $4.3\times 10^{-40}$ cm$^2$ ($9.4\times 10^{-44}$ cm$^2$). This is a 41-fold improvement over the previous EDELWEISS-II low-mass WIMP search for 7 GeV/$c^2$ WIMPs and is in tension with some recent WIMP signal hints.
arXivarXiv · · March 16, 2016
0
124
Commissioning of the vacuum system of the KATRIN Main Spectrometer
M. ArenzM. BabutzkaM. BahrJ.P. BarrettS. BauerM. BeckA. BeglarianJ. BehrensT. BergmannU. BessererJ. BlümerL.I. Bodine  +138
The KATRIN Main Spectrometer, a 1240 m³ ultra-high vacuum vessel, requires a pressure in the 10⁻¹¹ mbar range for neutrino-mass measurement. Its vacuum system combines six turbo-molecular pumps (screened against magnetic-field interference) and 3 km of non-evaporable getter strips. Commissioning with a 300°C bake-out showed that the system already operates close to the required pressure, nearly meeting the functional demands for the experiment starting in late 2016.
arXivarXiv · · March 3, 2016
0
60
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO4_4 scintillating bolometers
E.ArmengaudQ.ArnaudC.AugierA.BenoitL.BergeR.S.BoikoT.BergmannJ.BlumerA.BroniatowskiV.BrudaninP.CamusA.Cazes  +81
LUMINEU uses ZnMoO$_4$ scintillating bolometers enriched in $^{100}$Mo to search for neutrinoless double beta decay. The detectors measure both the light and heat from particle interactions, providing high energy resolution and background discrimination. Aboveground and underground tests with natural and enriched crystals show that energy resolution, $\alpha/\beta$ discrimination, and radioactive contamination meet specifications. Simulations indicate that zero background near 3 MeV can be achieved with hundreds of kg$\times$years of exposure, supporting future experiments targeting the inverted neutrino mass hierarchy.
arXivarXiv · · January 19, 2016
0
13
Scintillating bolometers based on ZnMoO4_4 and Zn100^{100}MoO4_4 crystals to search for 0νν2ββ decay of 100^{100}Mo (LUMINEU project): first tests at the Modane Underground Laboratory
D.V. PodaE. ArmengaudQ. ArnaudC. AugierA. BenoîtL. BergéR.S. BoikoT. BergmannJ. BlümerA. BroniatowskiV. BrudaninP. Camus  +81
The LUMINEU project develops scintillating bolometers based on ZnMoO$_4$ crystals to search for $0\nu2\beta$ decay of $^{100}$Mo. Using a low-thermal-gradient Czochralski technique, a Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time. Initial tests of the detectors at the Modane Underground Laboratory demonstrate high detection performance, laying the groundwork for large-scale experiments targeting the inverted neutrino mass hierarchy.
arXivarXiv · · February 4, 2015
0
Spectroscopic variability of two Oe stars
G. RauwT. MorelY. NazeT. EversbergF. AlvesW. ArnoldT. BergmannN.G. Correia ViegasR. FahedA. FernandoJ.N. Gonzalez-PerezL.F. Gouveia Carreira  +19
The paper analyzes 20 years of optical spectra of the Oe stars HD45314 and HD60848 to understand their contrasting X-ray properties. For HD60848, double-peaked H-alpha profiles are well reproduced by a Keplerian disk model with a 30° inclination, and a time lag between line equivalent-width variations is found. For HD45314, highly asymmetric lines and a major change in behavior between 2002 and 2013 outbursts prevent the simple disk model from fitting, suggesting a more complex disk velocity field linked to its peculiar gamma Cas-like X-ray emission.
arXivarXiv · · January 7, 2015
0
Focal-plane detector system for the KATRIN experiment
J. F. AmsbaughJ. BarrettA. BeglarianT. BergmannH. BichselL. I. BodineJ. BonnN. M. BoydT. H. BurrittZ. ChaouiS. ChilingaryanT. J. Corona  +39
The focal-plane detector system for the KATRIN experiment, designed to detect low-energy electrons from the main spectrometer, integrates a multi-pixel silicon p-i-n-diode array, custom readout electronics, superconducting magnets, vacuum systems, calibration devices, a scintillating veto, and a custom data-acquisition system. This paper describes the system and reports its performance after final installation.
arXivarXiv · · April 10, 2014
0
138
Dead layer on silicon p-i-n diode charged-particle detectors
B. L. WallJ. F. AmsbaughA. BeglarianT. BergmannH. C. BichselL. I. BodineN. M. BoydT. H. BurrittZ. ChaouiT. J. CoronaP. J. DoeS. Enomoto  +16
The dead layer on silicon p-i-n diode charged-particle detectors causes incomplete ionization collection, degrading energy deposition and resolution. By comparing Monte Carlo simulations with measured electron energy spectra from 12 to 20 keV for the KATRIN detector, this study shows that a substantial fraction of ionization in the dead layer escapes by diffusion: 46% is collected in the depletion zone, while the rest is neutralized. The simple model of a thinner dead layer with zero charge collection is ruled out.
arXivarXiv · · October 4, 2013
0
Axion searches with the EDELWEISS-II experiment
E. ArmengaudQ. ArnaudC. AugierA. BenoitL. BergéT. BergmannJ. BlümerA. BroniatowskiV. BrudaninP. CamusA. CazesB. Censier  +53
Using 448 kg.d of data from the EDELWEISS-II germanium bolometers, this work sets new 95% CL limits on axion couplings to photons ($g_{A\gamma}<2.13\times10^{-9}$ GeV$^{-1}$) for masses not fully covered by helioscopes, and to electrons ($g_{Ae}<2.56\times10^{-11}$). It also constrains $g_{Ae}\times g_{AN}^{\text{eff}}<4.70\times10^{-17}$. These results exclude DFSZ axions with $0.91\text{ eV}<m_A<80\text{ keV}$ and KSVZ axions with $5.73\text{ eV}<m_A<40\text{ keV}$.
arXivarXiv · · July 4, 2013
0
182
Background studies for the EDELWEISS dark matter experiment
E. ArmengaudC. AugierA. BenoîtL. BergéT. BergmannJ. BlümerA. BroniatowskiV. BrudaninB. CensierM. ChapellierF. CharlieuxF. Couedo  +46
The EDELWEISS-II collaboration used cryogenic Ge detectors in a 384 kg×days exposure to set a WIMP-nucleon spin-independent cross-section limit of $4.4\times10^{-8}$ pb at 90% C.L. for a WIMP mass of 85 GeV. Using GEANT4 simulations normalised to measured material radioactivity, the authors show that the expected gamma-ray background (20–200 keV) agrees with the observed 82 events/kg/day, and the computed neutron background of 1.0–3.1 events (90% C.L.) is consistent with the 5 nuclear-recoil events observed. Extending to EDELWEISS-III (800 g crystals, cleaner materials, extra internal shielding), the simulation predicts a gamma background of 14–44 events/kg/day and a neutron background of 0.7–1.4 events/year in a 24 kg fiducial mass, projecting sensitivity to cross-sections down to a few×$10^{-9}$ pb.
arXivarXiv · · May 15, 2013
0
102
Muon-induced background in the EDELWEISS dark matter search
EDELWEISS collaborationB. SchmidtE. ArmengaudC. AugierA. BenoitL. BergéT. BergmannJ. BlümerG. BresA. BroniatowskiV. BrudaninB. Censier  +46
Using the EDELWEISS muon-veto system, the muon flux underground at LSM was measured as $\Phi_{\mu} = (5.4 \pm 0.2 ^{+0.5}_{-0.9})$ muons/m$^2$/d, and muon-induced background rates in the Ge detectors were determined. The irreducible rate of muon-induced neutrons after vetoing was $\Gamma^{\mu-n}_{\rm irred} < 6 \cdot 10^{-4}$ evts/(kg$\cdot$d) at 90% C.L., corresponding to fewer than 0.6 expected events for the 3000 kg$\cdot$d exposure of EDELWEISS-3.
arXivarXiv · · February 28, 2013
0
87
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
EDELWEISS CollaborationE. ArmengaudC. AugierA. BenoîtL. BergéT. BergmannJ. BlümerA. BroniatowskiV. BrudaninB. CensierM. ChapellierF. Charlieux  +43
The EDELWEISS-II experiment searched for low-mass WIMPs (E < 20 keV) using germanium heat-and-ionization detectors. Over 113 kg.d of exposure, no exponential distribution of low-energy nuclear recoils from WIMP elastic scattering was found. For a 10 GeV WIMP mass, the observation of one event yields a 90% CL upper limit of $1.0 \times 10^{-5}$ pb on the spin-independent WIMP-nucleon cross-section, constraining the parameter space associated with CoGeNT, DAMA, and CRESST signals.
arXivarXiv · · July 7, 2012
0
The WR 140 periastron passage 2009: first results from MONS and other optical sources
R. FahedA. F. J. MoffatJ. ZorecT. EversbergA. N. ChenéF. AlvesW. ArnoldT. BergmannL. F. Gouveia CarreiraF. Marques DiasA. FernandoJ. Sanchez Gallego  +20
We present spectroscopy of the colliding-wind binary WR 140 (WC7 + O4-5) during its January 2009 periastron passage. Updated orbital parameters, revised WR and O star masses, and new mass-loss rate constraints are derived from the data, refining the archetype of this binary class.
arXivarXiv · · January 7, 2011
0
0
Variability monitoring of OB stars during the Mons campaign
T. MorelG. RauwT. EversbergF. AlvesW. ArnoldT. BergmannN. G. Correia ViegasR. FahedA. FernandoL. F. Gouveia CarreiraT. HungerJ. H. Knapen  +19
This paper presents preliminary results from a three-month campaign under the Mons project, which uses time-resolved Hα observations to monitor the wind and circumstellar properties of multiple OB stars. The central contribution is the characterization of short-term variability in these massive stars, offering insights into their dynamic environments through spectroscopic monitoring.
arXivarXiv · · September 23, 2010
0
Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter
Pierre Auger CollaborationP. Abreu…T. Bergmann
The Pierre Auger Observatory updates the correlation between ultra-high-energy cosmic rays (above $6\times10^{19}$ eV) and nearby extragalactic matter using data through December 2009 (69 events, up from 27). The fraction of arrival directions within $3.1^\circ$ of an AGN in the Véron-Cetty & Véron catalog within 75 Mpc is $(38^{+7}_{-6})\%$, down from the earlier $(69^{+11}_{-13})\%$ but still above the 21% isotropic expectation. The largest excess is near Cen A.
arXivarXiv · · September 9, 2010
0
580
Parity Violation in Hydrogen and Longitudinal Atomic Beam Spin Echo I
T. BergmannT. GasenzerM. DeKievietO. NachtmannM.-I. Trappe
This paper analyzes the propagation of hydrogen atoms in static electric and magnetic fields within a longitudinal atomic beam spin echo (lABSE) apparatus. The atoms acquire geometric (Berry) phases that reveal a new manifestation of parity (P) violation in atomic physics. Analytical and numerical calculations are provided for the metastable 2S states, and conditions for adiabatic evolution of the relevant atomic states are investigated. The work establishes the theoretical foundation for measuring P-violating geometric phases in lABSE experiments.
arXivarXiv · · November 10, 2008
0
Frequent collaborators
K. Eitel (15)
M. Weber (15)
D. Tcherniakhovski (11)
A. Beglarian (9)
P. J. Doe (9)
S. Enomoto (9)
F. Harms (9)
A. Menshikov (9)
M. Steidl (9)
S. Wüstling (9)
M. Kleifges (9)
S. Chilingaryan (8)