MCP
TK

T. Kozik

76 papers in the library

Papers

30
Measurement of the forward angle 12^{12}C+12^{12}C fragmentation differential cross sections at 62 MeV/nucleon
G. GuoG. Casini…T. Kozik
This paper reports high-precision measurements of forward-angle ($2^\circ \le \theta_\text{lab} \le 8^\circ$) differential cross sections for $^{12}\text{C}+^{12}\text{C}$ fragmentation at 62 MeV/nucleon using the FAZIA array. For heavier fragments ($Z=1$ to 6), angular distributions are better described by the Van Bibber formulation than by the Goldhaber model, indicating dissipative processes dominate in this angular range. Alpha particles show an anomalously narrow distribution, suggesting a cluster-structure origin. A kinematic scaling enables comparison with data at 50 and 95 MeV/nucleon.
arXivarXiv · · September 3, 2026
0
Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector
N. ChugS. D. Bass…T. Kozik
This paper reports a direct CPT symmetry test in ortho-positronium electromagnetic decays using the J-PET tomograph. The central contribution is a precise measurement of the CPT-sensitive angular correlation between the positronium spin and annihilation photon momenta, achieving an asymmetry amplitude of -0.00029 ± 0.00022 (stat.) from 47.8 million events collected over 356 days. This result, consistent with CPT symmetry, improves the statistical error by a factor of four compared to the previous best measurement, without requiring external magnetic fields.
arXivarXiv · · November 25, 2025
0
Model-independent measurement of isospin diffusion in Ni-Ni systems at intermediate energy
C. CiampiJ. D. Frankland…T. Kozik
The authors present a model-independent measurement of isospin diffusion in $^{58,64}$Ni+$^{58,64}$Ni collisions at 32 MeV/nucleon by combining two datasets: one from INDRA for impact-parameter reconstruction and one from the coupled INDRA-FAZIA apparatus for the quasiprojectile neutron-to-proton ratio. The isospin transport ratio as a function of impact parameter shows a clear evolution toward equilibration from semiperipheral to central collisions, providing data to constrain the symmetry energy of the nuclear Equation of State at sub- to saturation densities.
arXivarXiv · · December 18, 2024
0
Nanoporosity imaging by positronium lifetime tomography
K. DulskiE. BeyeneN. ChugC. CurceanuE. CzerwińskiM. DasM. GorgolB. JasińskaK. KacprzakŁ. KapłonG. KorcylT. Kozik  +16
We present a method for spatially resolved Positron Annihilation Lifetime Spectroscopy (PALS) that enables tomography of nanostructural porosity. By correlating the position and lifetime of positron annihilations, the technique images the size and distribution of free voids across an extended object. Using a stationary positron source and the J-PET tomograph, we simultaneously measured three porous materials—XAD4 polymer, silica aerogel IC3100, and polyvinyl toluene scintillator PVT—demonstrating the first porosity image obtained via this approach.
arXivarXiv · · September 12, 2024
0
4
Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner
P. MoskalD. Kumar…T. Kozik
Using a plastic-scintillator PET scanner that senses Compton scattering, this work measures the angular correlation between polarization planes of photons from positron-electron annihilation in a porous polymer. The observed distribution is narrower than predicted for maximally entangled two-photon states but broader than for separable photons, consistent with a model where pick-off annihilation produces unentangled photons while direct and para-positronium annihilations yield maximally entangled pairs. This shows that the annihilation mechanism in matter affects entanglement degree.
arXivarXiv · · July 11, 2024
0
Study of quasi-projectile properties at Fermi energies in 48Ca projectile systems
S. UpadhyayaK. MazurekT. KozikD. GruyerG. CasiniS. PiantelliL. BaldesiS. BarliniB. BorderieR. BougaultA. CamaianiC. Ciampi  +23
By analyzing FAZIA data for the neutron-rich $^{48}$Ca projectile at Fermi energies, this study isolates quasi-projectile (QP) fragments and compares their properties with HIPSE simulations. The central finding is that the N/Z ratio of QP fragments decreases with beam energy, and this trend is already present from the initial reaction phase. The result points to pre-equilibrium particle emission as a likely explanation for the observed N/Z reduction, clarifying the role of fast emissions in shaping the QP fragments for neutron-rich systems.
arXivarXiv · · February 14, 2024
0
Isospin diffusion from 40,48^{40,48}Ca+40,48+^{40,48}Ca experimental data at Fermi energies: Direct comparisons with transport model calculations
Q. FableL. Baldesi…T. Kozik
This work studies isospin equilibration in $^{40,48}\text{Ca}+^{40,48}\text{Ca}$ cross-bombarding reactions at 35 MeV/nucleon. Using the quasiprojectile asymmetry parameter $\delta=(N-Z)/A$ and a new impact parameter reconstruction method, the isospin transport ratio is compared directly between experimental data and filtered antisymmetrized molecular dynamics (AMD)+GEMINI++ calculations. The results show that isospin equilibration increases as the impact parameter decreases from 9 to 3 fm, but full equilibration is not reached. Only a weak sensitivity to the stiffness of the nuclear equation of state is observed, with better agreement for neutron-rich systems.
arXivarXiv · · December 4, 2023
0
Feasibility studies for imaging e+^{+}e−^{-} annihilation with modular multi-strip detectors
S. SharmaL. Povolo…T. Kozik
This paper reports the first feasibility study of using modular multi-strip detectors to image e$^+$e$^-$ annihilations on a positron beamline. The goal is to enable inertial sensing with positronium (Ps) for testing the Einstein equivalence principle. Two detection modules were evaluated for reconstruction performance and spatial resolution, confirming the detectors' applicability for gravitational studies of Ps.
arXivarXiv · · September 12, 2023
0
4
Quasiprojectile breakup and isospin equilibration at Fermi energies: an indication of longer projectile-target contact times?
C. CiampiS. Piantelli…T. Kozik
The paper investigates quasiprojectile breakup in semiperipheral and peripheral collisions of $^{58,64}$Ni+$^{58,64}$Ni at 32 and 52 MeV/nucleon using the INDRA-FAZIA apparatus. Using the isospin transport ratio technique on the neutron-to-proton ratio of breakup fragments, the authors find that, for the same centrality, the breakup channel exhibits greater isospin equilibration than the binary output. This is interpreted as evidence of longer average projectile-target contact times for the breakup channel, supported by AMD+GEMINI++ simulations.
arXivarXiv · · August 29, 2023
0
Examination of cluster production in excited light systems at Fermi energies from new experimental data and comparison with transport model calculations
C. FrosinS. Piantelli…T. Kozik
Cluster production in light nuclear systems at Fermi energies is examined through four reactions—$^{32}$S+$^{12}$C and $^{20}$Ne+$^{12}$C at 25 and 50 MeV/nucleon—measured with the FAZIA detector. Experimental fragment multiplicities, angular distributions, and energy spectra are compared with AMD and HIPSE transport models, each combined with decay afterburners. The AMD model's inclusion of clustering and inter-clustering processes is essential for reproducing the data; the role of cluster aggregation in reaction dynamics grows with bombarding energy, confirming its importance for these light systems.
arXivarXiv · · March 30, 2023
0
Characterization of the breakup channel in the asymmetric systems 40,48^{40,48}Ca+12^{12}C at 25 and 40 MeV/nucleon
S.PiantelliG.Casini…T.Kozik
This study analyzes the breakup channel in asymmetric $^{40,48}$Ca+$^{12}$C reactions at 25 and 40 MeV/nucleon using the FAZIA array. The focus is on sources produced in dissipative collisions, partially from incomplete fusion. The central finding is that carbon fragments reconstructed via particle-fragment correlations largely serve as the light partner of a scission, with the relative velocity between breakup fragments examined as a function of beam energy and neutron content.
arXivarXiv · · March 23, 2023
0
J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
S. SharmaJ. Baran…T. Kozik
The J-PET detector, built from inexpensive plastic scintillators, enables fundamental physics studies. A new modular prototype, with each module containing 13 plastic scintillators as a stand-alone detection unit, was commissioned. This design allows tests of discrete symmetries (C, P, T) in positronium decays and studies of photon polarization entanglement via Compton scattering, with potential for use with positron and positronium beams. Preliminary tests on two units in a continuous positron beam at Trento are reported.
arXivarXiv · · January 7, 2023
0
9
First results from the INDRA-FAZIA apparatus on isospin diffusion in 58,64^{58,64}Ni+58,64^{58,64}Ni systems at Fermi energies
C. CiampiS. Piantelli…T. Kozik
In the first experimental campaign of the combined INDRA-FAZIA apparatus at GANIL, the isospin equilibration process was studied in $^{58,64}$Ni+$^{58,64}$Ni reactions at 32 and 52 MeV/nucleon. Using the isospin transport ratio technique, the neutron content of the quasiprojectile residue and its evaporated light ejectiles were measured from peripheral to semi-central collisions. Results show a clear relaxation of the initial isospin imbalance with increasing centrality, with stronger equilibration at 32 MeV/nucleon, consistent with longer projectile-target interaction times.
arXivarXiv · · May 20, 2022
0
Dynamical fission of the quasiprojectile and isospin equilibration for the system 80Kr+ 48 Ca at 35 MeV/nucleon
S. PiantelliG. Casini…T. Kozik
For the system $^{80}\mathrm{Kr}+^{48}\mathrm{Ca}$ at 35 $\mathrm{MeV}/\mathrm{nucleon}$, the degree of isospin equilibration between the two fission fragments from dynamical quasiprojectile fission is investigated and found to depend on their charge asymmetry. The experimental data, collected with the FAZIA setup, are compared with the AMD+GEMINI model, which provides insight into the process timescale. The central contribution is the characterization of this isospin-equilibration–asymmetry correlation as a signature of the reaction dynamics.
arXivarXiv · · October 1, 2020
0
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
P. MoskalT. BednarskiSz. NiedzwieckiM. SilarskiE. CzerwinskiT. KozikJ. ChhokarM. BałaC. CurceanuR. Del GrandeM. DadgarK. Dulski  +27
The J-PET 24-module prototype, a plastic-scintillator-strip scanner with a 300 mm axial field of view, demonstrates a cost-effective approach to total-body PET. Its triggerless DAQ and digital front-end required novel calibration for time, thresholds, and gain. The prototype achieves a coincidence resolving time of CRT = $490 \pm 9$ ps, yielding a position reconstruction accuracy of $\sigma(\Delta l) = 18$ mm that is largely position-independent.
arXivarXiv · · August 25, 2020
0
20
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
N. G. SharmaM. Silarski…T. Kozik
The paper presents a new signal-processing method for reconstructing hit-position and hit-time in long plastic scintillator detectors, motivated by J-PET scanners. The method uses the Mahalanobis distance to measure the similarity between registered signals and synchronized model signals stored in a library. Validated on a two-strip J-PET prototype (5×9×300 mm³), the method yields Time-of-Flight (TOF) resolution of 325 ps FWHM and spatial resolution of 25 mm FWHM. Compared to the simpler Linear Fitting method, the Mahalanobis approach achieves comparable TOF resolution with fewer threshold levels, reducing electronics cost.
arXivarXiv · · April 27, 2020
0
0
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
S. SharmaJ. Chhokar…T. Kozik
The authors establish a relationship between Time-Over-Threshold (TOT) and energy loss for photons in the plastic scintillators of the J-PET scanner, using a $^{22}$Na source placed at the scanner centre. The source emits 511 keV and 1275 keV photons, and by measuring the scattering angle from the J-PET geometry, the incident photon energy and deposited energy are determined unambiguously. The resulting TOT-energy calibration covers the 100–1000 keV range, enabling TOT to replace charge integration for combined time and energy readout in the J-PET tomograph.
arXivarXiv · · November 27, 2019
0
67
Performance assessment of the 2γγ positronium imaging with the total-body PET scanners
P. MoskalD. Kisielewska…T. Kozik
This paper assesses the feasibility of reconstructing ortho-positronium lifetime images from 2γ annihilations in total-body PET scanners. Simulations using $^{44}$Sc (a positron and prompt gamma emitter) and triple coincidences show that total-body sensitivity for lifetime imaging is 12.2 times (LYSO) and 4.7 times (plastic) higher than standard 2γ imaging with a 20 cm AFOV LYSO scanner. Spatial and time resolution are evaluated for coincidence resolving times of 140 ps, 50 ps, and 10 ps.
arXivarXiv · · November 15, 2019
0
89
Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
N. KrawczykB. C. Hiesmayr…T. Kozik
The J-PET tomograph, built from plastic scintillators, detects 511 keV photons from electron-positron annihilation. Compton scattering, most probable at an angle orthogonal to the photon's electric field, allows polarization determination by registering multiple scatterings. This study estimates the physical limitations on the accuracy of such polarization measurements for J-PET.
arXivarXiv · · January 18, 2019
0
1
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
P. MoskalN. Krawczyk…T. Kozik
The J-PET detector, which registers 511 keV photons via Compton scattering in plastic scintillators, can determine the linear polarization of individual photons on an event-by-event basis. For a scattering angle of about 82°, the single-event polarization resolution is approximately 40°, but for samples exceeding ten thousand events, the relative average polarization can be determined to within a few degrees. This extends polarization measurements to the MeV energy range, five orders of magnitude beyond the optical regime, enabling studies of quantum entanglement and discrete symmetries in positronium decays.
arXivarXiv · · September 27, 2018
0
82
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
K. DulskiC. Curceanu…T. Kozik
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET detector built from plastic scintillators and is designed for both medical imaging and studies of positronium properties. This paper reports the commissioning of J-PET for positronium decay studies. By analyzing positron lifetime in a porous polymer, the authors demonstrate that J-PET can simultaneously image the density distribution of annihilation points and perform positron annihilation lifetime spectroscopy.
arXivarXiv · · September 12, 2018
0
32
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
J. RajA. Gajos…T. Kozik
This work assesses the feasibility of testing time reversal (T) violation using polarized annihilation photons from ortho-positronium decay with the J-PET detector. J-PET, an organic-scintillator scanner with axial symmetry and high acceptance, can measure both momenta and polarization vectors of annihilation photons. The unique polarization measurement enables construction of a T-violation operator from photon momenta before and after scattering in the detector, making J-PET suitable for this discrete-symmetry test beyond medical imaging.
arXivarXiv · · September 4, 2018
0
9
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
G. KorcylP. Białas…T. Kozik
This paper proposes and evaluates a single-chip FPGA-SoC platform for real-time tomographic data processing using the J-PET scanner. The system directly connects to scanner data streams, performing event building, filtering, coincidence search, and region-of-response reconstruction in programmable logic, with visualization on integrated processors. It significantly reduces data volume by converting raw data to list-mode representation while generating on-the-fly visualization, eliminating the need for powerful local computing facilities.
arXivarXiv · · July 26, 2018
0
130
Feasibility study of the positronium imaging with the J-PET tomograph
P. MoskalD. Kisielewska…T. Kozik
This paper explores the feasibility of imaging ortho-positronium annihilation into three photons using the J-PET tomograph built from plastic scintillators. The proposed method determines hit-times and positions of registered photons to reconstruct annihilation points and ortho-positronium lifetimes event-by-event. Simulations with a cylindrical phantom containing materials with lifetimes from 2.0 ns to 3.0 ns yield a mean lifetime resolution of about 40 ps, which may enable detection of morphological changes in cell structures, as suggested by prior Positron Annihilation Lifetime Spectroscopy measurements.
arXivarXiv · · May 29, 2018
0
233
Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
A. GajosC. Curceanu…T. Kozik
This paper investigates the feasibility of testing time-reversal (T) symmetry in a purely leptonic system using the J-PET detector. Two strategies are proposed to search for T violation via non-vanishing angular correlations of final-state observables in the decays of metastable triplet positronium. A pilot measurement with J-PET is presented, along with an assessment of its performance in reconstructing three-photon decays and an analysis of the detector's sensitivity to T-violation-sensitive observables.
arXivarXiv · · April 19, 2018
0
Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner
R. MasełekW. Krzemien…T. Kozik
The authors propose an energy-based method to separate 511 keV annihilation photons from prompt de-excitation photons in the J-PET scanner for 2+1 photon tomography. By setting an energy deposited threshold, signals below the threshold are identified as 511 keV photons and those above as prompt photons. Analyzing several radioisotopes, they select $^{44}\mathrm{Sc}$ as the most promising candidate. Simulations with GATE and J-POS yield an optimal threshold of about 375 keV, achieving nearly 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.
arXivarXiv · · March 2, 2018
0
5
Human Tissues Investigation Using PALS Technique
B. JasińskaB. Zgardzińska…T. Kozik
This study applies Positron Annihilation Lifetime Spectroscopy (PALS) to uterine leiomyoma and normal tissue from patients. Significant differences in all PALS parameters were observed between the two tissue types. Tumorous tissues showed longer free annihilation and ortho-positronium lifetimes than healthy tissues. For most patients, the intensities of these annihilation channels were lower in tumors. The paper's novel contribution is the first determination of the $3\gamma$ annihilation fraction in such studies, used to characterize changes in tissue porosity during morphological alteration.
arXivarXiv · · November 13, 2017
0
66
J-PET: a new technology for the whole-body PET imaging
S. NiedźwieckiP. Białas…T. Kozik
J-PET is the first whole-body PET scanner built from plastic scintillators instead of conventional crystals. Its 192 detection modules are arranged axially in three layers, forming a 85-cm diameter cylindrical chamber with a 50-cm axial field of view. The long strips of plastic scintillators provide low light attenuation, superior timing, and easy scalability of the axial field of view, offering a cost-effective path to whole-body PET imaging and compatibility with MR and CT inserts.
arXivarXiv · · October 31, 2017
0
211
Introduction of total variation regularization into filtered backprojection algorithm
L. RaczyńskiW. Wiślicki…T. Kozik
This paper extends the filtered backprojection (FBP) algorithm by introducing total variation (TV) regularization, replacing the common use of apodizing functions. The proposed method is validated on a Derenzo-type phantom and yields higher cross-correlation coefficients between the reconstructed and true radioactive tracer distribution compared to standard FBP, demonstrating improved reconstruction quality.
arXivarXiv · · October 31, 2017
0
1
Three-dimensional image reconstruction in J-PET using Filtered Back Projection method
R. Y. ShopaK. Klimaszewski…T. Kozik
The paper presents a 3D image reconstruction method for the J-PET tomograph using Filtered Back Projection, implemented in the STIR and TomoPy packages. Simulated 511 keV annihilation photons from a 1 mm spherical source were detected by a cylindrical detector, with hit coordinates smeared to match experimental resolutions. Without time-of-flight information, consistent Point Spread Functions of approximately 5-7 mm transverse and 9-20 mm longitudinal were obtained using STIR.
arXivarXiv · · October 30, 2017
0
8
Frequent collaborators
P. Moskal (58)
G. Korcyl (57)
P. Kowalski (53)
M. Silarski (52)
Z. Rudy (48)
E. Czerwiński (45)
A. Gajos (45)
E. Kubicz (45)
L. Raczyński (43)
W. Wiślicki (42)
W. Krzemień (41)
M. Pałka (41)