MCP
TW

T. Walker

5 papers in the library

Papers

5
A prototype differential atom interferometer for fundamental physics
C. F. A. BaynhamR. HobsonO. BuchmuellerD. EvansL. HawkinsL. Iannizzotto-VenezzeA. JossetD. LeeE. PasatembouB. E. SauerM. R. TarbuttT. Walker  +80
The AION project reports a tabletop prototype of a single-photon long-baseline atom interferometer using the $^{87}\text{Sr}$ clock transition. The detector operates at the Standard Quantum Limit (SQL), producing a signal with no unexpected noise beyond atom shot noise, and remains at the SQL even when additional laser phase noise is introduced. This result demonstrates a key milestone toward extending atom interferometers to long baselines, enabling searches for dark matter and gravitational waves in the mid-frequency band around 1 Hz.
arXivarXiv · · April 12, 2025
0
16
Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser
G. BruhaugH. G. RinderknechtY. EM. S. WeiR. B. BrannonD. GuyR. G. PeckN. LandisG. BrentR. FairbanksC. McAteeT. Walker  +8
A hardened THz energy meter for the kilojoule-scale OMEGA EP laser measures THz pulses from high-intensity laser-plasma interactions. It uses a shielded pyrometer with a second identical pyrometer for background subtraction, configurable for 0.3–10 THz and microjoule-to-joule energies via filtration and aperture changes. Calibrated up to 1000 nJ absorbed energy, initial experiments detected up to 15 µJ at the detector, potentially corresponding to hundreds of mJ depending on emission models.
arXivarXiv · · November 8, 2022
0
Magnetocardiography with a modular spin-exchange relaxation free atomic magnetometer array
R WyllieM KauerG SmetanaR WakaiT Walker
This paper presents a portable four-channel atomic magnetometer array operating in the spin-exchange relaxation-free (SERF) regime for biomagnetic measurements, particularly foetal magnetocardiography. Its modular design allows independent positioning and orientation of each sensor, enabling non-planar array geometries. In a magnetically shielded room, adult magnetocardiograms were acquired with a single-channel baseline sensitivity of 6–11 fT Hz$^{-1/2}$, matching the room's independently measured noise level.
arXivarXiv · · June 23, 2011
0
161
DUSEL Theory White Paper
S. RabyT. WalkerK.S. BabuH. BaerA.B. BalantekinV. BargerZ. BerezhianiA. de GouveaR. DermisekA. DolgovP. Fileviez PerezG. Gabadadze  +19
This white paper, produced by the 2008 DUSEL Theory Workshop at Ohio State University, presents the scientific case for the Deep Underground Science and Engineering Laboratory (DUSEL) in Lead, South Dakota. It focuses on six proposed experiments: long baseline neutrino oscillations, proton decay, dark matter, astrophysical neutrinos, neutrinoless double beta decay, and N-Nbar oscillations. The paper aims to inform NSF and Congressional decision-making about the facility's physics potential.
arXivarXiv · · October 24, 2008
0
27
Spin-axis relaxation in spin-exchange collisions of alkali atoms
S. KadlecekT. WalkerD.K. WalterC. EricksonW. Happer
We present calculations of spin-relaxation rates of alkali-metal atoms due to the spin-axis interaction in binary collisions. For high-temperature conditions, classical-path trajectories yield rates nearly identical to the distorted-wave Born approximation. The coupling coefficients derived from binary-collision measurements match those from molecular decoupling experiments and follow a simple scaling law.
arXivarXiv · · September 26, 2000
0
Frequent collaborators
C. F. A. Baynham (1)
R. Hobson (1)
O. Buchmueller (1)
D. Evans (1)
L. Hawkins (1)
L. Iannizzotto-Venezze (1)
A. Josset (1)
D. Lee (1)
E. Pasatembou (1)
B. E. Sauer (1)
M. R. Tarbutt (1)
O. Ennis (1)