MCP
VB

V. Bondar

18 papers in the library

Papers

18
New high-sensitivity search for neutron to mirror-neutron oscillations at the PSI UCN source
N. J. AyresZ. BerezhianiG. BisonK. BodekV. BondarP. -J. ChiuM. DaumC. B. DoorenbosS. EmmeneggerK. KirchV. KletzlJ. Krempel  +10
A collaboration at the Paul Scherrer Institute performed a high-sensitivity search for neutron to mirror-neutron (n-n') oscillations using a dedicated apparatus and the PSI UCN source. By analyzing neutron losses under magnetic fields from 5 to 109 microT with field mapping and Monte Carlo simulations, no evidence of oscillations was found. New limits on the oscillation time constant exclude the previously claimed parameter space to 99.98% confidence.
arXivarXiv · · February 26, 2026
0
Simulation and optimization of the Active Magnetic Shield of the n2EDM experiment
N. J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudG. L. CaratschE. ChanelW. ChenC. CrawfordV. CzamlerC. B. Doorenbos  +38
The n2EDM experiment searches for the neutron electric dipole moment using passive shielding and an Active Magnetic Shield (AMS) of eight coils on an irregular grid. The AMS suppresses external disturbances up to ±50 μT (homogeneous) and ±5 μT/m (gradients) to a few μT. This work presents a finite-element simulation of AMS fields inside the magnetically shielded room, accurate enough to match measurements. The simulation is demonstrated by optimizing the number and placement of feedback sensors with a genetic algorithm.
arXivarXiv · · January 30, 2026
0
Ultracold neutron energy spectrum and storage properties from magnetically induced spin depolarization
N. J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudD. BowlesG. L. CaratschE. ChanelW. ChenP. -J. ChiuC. B. Crawford  +44
This paper presents a method to extract the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements in the n2EDM apparatus. The approach also distinguishes specular from diffuse wall collisions, as demonstrated by comparing two storage chambers. The method is validated against an independent magnetic-filter measurement, and the extracted spectrum is used to compute the neutron center-of-mass offset, a key systematic effect for neutron electric dipole moment searches.
arXivarXiv · · November 10, 2025
0
Phase space compression of a positive muon beam in two spatial dimensions
A. AntogniniN. J. AyresI. BelosevicV. BondarA. EggenbergerM. HildebrandtR. IwaiK. KirchA. KnechtG. LospallutoJ. NuberA. Papa  +4
The muCool collaboration demonstrates the first simultaneous phase-space compression of a positive muon beam in two spatial dimensions. Using a cryogenic helium gas target with a strong density gradient in a homogeneous magnetic field and a complex electric field, the keV-energy, sub-mm-size beam is compressed, enabling a factor $10^5$ improvement in brightness for precision muSR and other measurements. This is the first stage of a novel high-brightness muon beam; the next phase will extract the beam into vacuum.
arXivarXiv · · October 28, 2024
0
Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments
N. J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudD. BowlesE. ChanelW. ChenP.-J. ChiuC. B. CrawfordO. Naviliat-Cuncic  +38
The paper reports a degaussing procedure for the magnetically shielded room (MSR) of the n2EDM experiment that halves the residual magnetic field. With the full coil system and vacuum vessel installed, the field inside the ~1.4 m³ volume is reduced below 300 pT and made more uniform. The procedure is also faster and generates less heat, cutting the thermal relaxation time from 12 h to ~1.5 h.
arXivarXiv · · September 28, 2023
0
A large 'Active Magnetic Shield' for a high-precision experiment
C. AbelN.J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudE.ChanelJ. ChenW. ChenP.-J. ChiuC.B. Crawford  +39
The paper presents the design and implementation of a large Active Magnetic Shield (AMS) for the n2EDM neutron electric dipole moment experiment. The AMS, a system of eight feedback-controlled coils on an irregular grid around a 5m cubic magnetically shielded room, compensates static and variable magnetic fields up to ±50 μT (homogeneous) and ±5 μT (first-order gradients), suppressing them to a few μT in the sub-Hertz range. This fulfills the experiment's stringent stability requirements while remaining compact for spatial constraints.
arXivarXiv · · July 14, 2023
0
Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI
N. J. AyresG. BisonK. BodekV. BondarT. BouillaudE. ChanelP.-J. ChiuB. ClementC. B. CrawfordM. DaumC. B. DoorenbosS. Emmenegger  +35
This paper reports a search for a short-range, spin-dependent interaction mediated by axion-like particles, using ultracold neutrons stored in vacuum near material surfaces. The dominant systematic uncertainty from magnetic-field gradients was controlled to about 4 pT/cm. No new interaction was found, and a new limit on the monopole-dipole coupling $g_s g_p \lambda^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) was set for force ranges $5\,\mu\text{m} < \lambda < 25\,\text{mm}$, improving the previous limit by a factor of 2.7 and providing the current tightest constraint obtained with free neutrons.
arXivarXiv · · March 31, 2023
0
Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelC. B. CrawfordM. DaumB. DechenauxS. EmmeneggerP. Flaux  +26
This paper reports a null result from a demonstration experiment that searched for ultralight axion dark matter by looking for a frequency modulation in the free spin-precession signal of $^{199}$Hg in a $1\,\mathrm{\mu T}$ magnetic field. The axion would produce an oscillating pseudo-magnetic field via its coupling to nuclear spins. The search covers axion masses $10^{-16}\,\mathrm{eV} \lesssim m_a \lesssim 10^{-13}\,\mathrm{eV}$ and achieves a peak sensitivity to the axion-nucleon coupling $g_{aNN} \approx 3.5 \times 10^{-6}\,\mathrm{GeV}^{-1}$.
arXivarXiv · · December 2, 2022
0
22
The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
N.J. AyresG. BanG. BisonK. BodekV. BondarT. BouillaudB. ClementE. ChanelP.-J. ChiuC. B. CrawfordM. DaumC. B. Doorenbos  +32
The n2EDM experiment's magnetically shielded room (MSR) provides a 2.92m-sided cubic interior (25m³) with 87 openings for apparatus and intermediate space for electronics. Characterization shows a remanent magnetic field below 100pT in the central 1m³ and below 600pT throughout the entire inner volume, with a quasi-static shielding factor of about 100,000 at 0.01Hz across all spatial directions, increasing to 10^8 above 1Hz.
arXivarXiv · · June 21, 2022
0
Improved search for neutron to mirror-neutron oscillations in the presence of mirror magnetic fields with a dedicated apparatus at the PSI UCN source
N.J.AyresZ.BerezhianiR.BiondiG.BisonK.BodekV.BondarP.-J.ChiuM.DaumR.T.DinaniC.B.DoorenbosS.EmmeneggerK.Kirch  +13
This paper presents a new search for neutron to mirror-neutron ($n-n'$) oscillations using ultracold neutrons stored in a large 1.47 m$^3$ vessel at PSI, designed to test for anomalous loss as a function of applied magnetic field $B$. The experiment will reach sensitivity to oscillation times $\tau_{nn'}/\sqrt{\cos(\beta)}$ above one hundred seconds, scanning $B$ to confirm or exclude previously reported potential signals, where $\beta$ is the angle between the mirror magnetic field $B'$ and $B$.
arXivarXiv · · October 31, 2021
0
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
N. J. AyresG. BanG. BisonK. BodekV. BondarP.-J. ChiuB. ClementC. B. CrawfordM. DaumS. EmmeneggerM. FertlA. Fratangelo  +28
This paper presents the first dedicated study of magnetic Johnson-Nyquist noise (JNN) from metal electrodes in neutron electric-dipole-moment (nEDM) experiments. The authors derive surface- and volume-averaged RMS noise amplitudes for a cylindrical geometry and model noise as current dipoles to simulate spatial and temporal JNN dependencies. Applying these to the n2EDM apparatus, they show that JNN does not limit the $^{133}$Cs and $^{199}$Hg co-magnetometers and that its impact is negligible for nEDM searches down to $4\times 10^{-28}\,e\cdot\mathrm{cm}$ per measurement, making solid aluminum electrodes viable.
arXivarXiv · · February 2, 2021
0
The design of the n2EDM experiment
N. J. AyresG. BanL. BienstmanG. BisonK. BodekV. BondarT. BouillaudE. ChanelJ. ChenP.-J. ChiuB. ClémentC. Crawford  +49
n2EDM, a next-generation experiment under construction at PSI, targets a neutron electric dipole moment with an order-of-magnitude better sensitivity than its predecessor. The design overview covers the experimental method, setup, sensitivity requirements, and technical implementation, with provisions for further substantial improvements.
arXivarXiv · · January 21, 2021
0
A search for neutron to mirror-neutron oscillations
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelP.-J. ChiuC. CrawfordM. DaumR. T. DinaniS. Emmenegger  +31
The neutron electric dipole moment collaboration performed a dedicated search for neutron to mirror-neutron oscillations at the Paul Scherrer Institute, finding no evidence. New lower limits on the oscillation time $\tau_{nn'}$ were set: $\tau_{nn'} > 352$ s at $B'=0$ (95% C.L.), $\tau_{nn'} > 6$ s for all $0.4~\mu\text{T} < B' < 25.7~\mu\text{T}$ (95% C.L.), and $\tau_{nn'}/\sqrt{\cos\beta} > 9$ s for all $5.0~\mu\text{T} < B' < 25.4~\mu\text{T}$ (95% C.L.), where $\beta$ is the fixed angle between the applied and local mirror magnetic fields. These are the best constraints measured around $B' \sim 10~\mu$T and $B' \sim 20~\mu$T.
arXivarXiv · · September 23, 2020
0
Measurement of the permanent electric dipole moment of the neutron
C. AbelS. AfachN. J. AyresC. A. BakerG. BanG. BisonK. BodekV. BondarM. BurghoffE. ChanelZ. ChowdhuriP.-J. Chiu  +72
We report a neutron electric dipole moment (EDM) measurement at the Paul Scherrer Institute using Ramsey's method with ultracold neutrons. The experiment employed a $^{199}$Hg co-magnetometer and cesium magnetometer array to control magnetic field changes. The result, $d_n = (0.0 \pm 1.1_{\text{stat}} \pm 0.2_{\text{sys}}) \times 10^{-26} e\,\text{cm}$, is consistent with zero and constrains time-reversal-violating physics beyond the Standard Model.
arXivarXiv · · January 31, 2020
0
1k+
nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelP.-J. ChiuM. DaumS. EmmeneggerL. Ferraris-BouchezP. Flaux  +31
This paper reports the data-taking strategy for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute, using ultracold neutrons stored in a single chamber. The magnetic field, monitored by a mercury cohabiting magnetometer and cesium magnetometers, was precisely controlled with field coils. The approach balances statistical sensitivity and systematic effect control, achieving an irreducible sensitivity better than $1 \times 10^{-26}$ ecm.
arXivarXiv · · November 9, 2018
0
The n2EDM experiment at the Paul Scherrer Institute
C. AbelN. J. AyresG. BanG. BisonK. BodekV. BondarE. ChanelP.-J. ChiuB. ClementC. CrawfordM. DaumS. Emmenegger  +36
The n2EDM experiment at the Paul Scherrer Institute is a new spectrometer for measuring the neutron electric dipole moment (nEDM) at room temperature in vacuum using ultracold neutrons. Its design features a large double storage chamber and neutron transport optimized for the PSI UCN source. Building on the previous apparatus, the new setup is calculated to achieve an order of magnitude improvement in sensitivity.
arXivarXiv · · November 6, 2018
0
Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations
C. AbelN. AyresG. BisonK. BodekV. BondarP.-J. ChiuM. DaumS. EmmeneggerP. FlauxL. Ferraris-BouchezW. C. GriffthN. Hild  +24
The nEDM collaboration at PSI conducted a new search for neutron–mirror-neutron ($n-n'$) oscillations, a hypothetical mixing process faster than neutron beta decay. Run configurations were chosen with filling time 29 s, storage times 180 s and 380 s, and applied magnetic fields of 10 µT and 20 µT to overlap with previous efforts and improve sensitivity. The normalization technique and magnetic field characterization required for the experiment are described. The resulting statistical sensitivity is comparable to the leading constraints on $n-n'$ oscillations.
arXivarXiv · · November 5, 2018
0
Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields
C. AbelN.J. AyresG. BanG. BisonK. BodekV. BondarM. DaumM. FairbairnV.V. FlambaumP. GeltenbortK. GreenW.C. Griffith  +36
This paper reports a search for axion-like dark matter by measuring the ratio of spin-precession frequencies of ultracold neutrons and $^{199}$Hg atoms in electric and magnetic fields. No signal was observed for axion masses $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. The null result provides the first laboratory constraints on the coupling of axion dark matter to gluons, improving on astrophysical limits by up to three orders of magnitude, and improves on previous laboratory constraints on the axion–nucleon coupling by up to a factor of 40.
arXivarXiv · · August 21, 2017
0
Frequent collaborators
K. Kirch (17)
G. Bison (16)
K. Bodek (16)
B. Lauss (16)
D. Ries (16)
P. Schmidt-Wellenburg (16)
J. Zejma (16)
G. Zsigmond (16)
T. Lefort (15)
G. Pignol (15)
S. Roccia (15)
N. Severijns (15)