MCP
VD

V. Datskov

12 papers in the library

Papers

12
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
CUORE CollaborationM. Sisti…V. Datskov
CUORE, a 741 kg array of TeO₂ bolometers searching for neutrinoless double beta decay of ¹³⁰Te, aims for a 1σ half-life sensitivity of 10²⁶ y in five years at a background of 0.01 counts/keV/kg/y. Its precursor, CUORE‑0 (a single 52‑bolometer tower), began taking data in spring 2013 to verify expected performance. This paper reports CUORE’s status and presents the first CUORE‑0 data.
arXivarXiv · · February 12, 2015
0
11
CUORE-0 results and prospects for the CUORE experiment
CUORE CollaborationD.R. Artusa…V. Datskov
The CUORE-0 detector, a single CUORE-style tower of 52 TeO₂ bolometers, tested the background and performance of the upcoming CUORE experiment. With 18.1 kg·yr exposure, CUORE-0 data show the background meets CUORE's design goal, and the projected neutrinoless double-beta decay half-life sensitivity of $1.6\times10^{26}$ yr (1σ) for $^{130}$Te in five years of live time is within reach.
arXivarXiv · · February 9, 2015
0
1
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
D. R. ArtusaF. T. Avignone III…V. Datskov
The CUORE experiment uses 741 kg of TeO$_2$ crystals with 5 keV (0.2%) energy resolution to search for neutrinoless double beta decay of $^{130}$Te. Its projected half-life sensitivity after five years is $1.6\times10^{26}$ y at $1\sigma$ ($9.5\times10^{25}$ y at 90% CL), corresponding to an effective Majorana mass limit of 40--100 meV (50--130 meV). The paper further notes that adding auxiliary light detectors for background rejection could enable bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and other nuclei.
arXivarXiv · · July 4, 2014
0
0
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
D. R. ArtusaF. T. Avignone III…V. Datskov
This paper reviews the status and outlook of bolometric neutrinoless double beta decay ($0\nu\beta\beta$) searches, focusing on the goal of fully exploring the inverted neutrino mass hierarchy. By simulating a future CUORE-like detector array with improved background suppression from simultaneous heat and light readout, the authors show that a bolometric experiment with approximately 1 ton of isotope mass could reach a sensitivity to the effective Majorana neutrino mass $|m_{ee}|$ of order 10–20 meV, thereby covering the entire inverted hierarchy region. The paper also identifies key challenges and R&D priorities.
arXivarXiv · · April 17, 2014
0
142
Searching for neutrinoless double-beta decay of 130^{130}Te with CUORE
CUORE CollaborationD. R. Artusa…V. Datskov
CUORE is a cryogenic bolometer array built to search for neutrinoless double-beta decay of $^{130}$Te, a hypothesized lepton-number-violating process. The detector uses 988 TeO$_2$ crystals operated at 10 mK, containing 206 kg of $^{130}$Te with an average energy resolution of 5 keV. The projected half-life sensitivity after five years of live time is $1.6\times10^{26}$ y at $1\sigma$, corresponding to an upper limit on the effective Majorana mass of 40--100 meV.
arXivarXiv · · February 25, 2014
0
234
Initial performance of the CUORE-0 experiment
CUORE CollaborationD. R. Artusa…V. Datskov
CUORE-0, a cryogenic array of TeO$_2$ bolometers, searches for neutrinoless double-beta decay of $^{130}$Te. Analyzing 7.1 kg·y of exposure, it measures a background rate of $0.071 \pm 0.011$ counts/keV/kg/y in the 2.47–2.57 MeV region of interest and $0.019 \pm 0.002$ counts/keV/kg/y in the 2.70–3.90 MeV $α$-dominated region—a factor of 6 improvement over its predecessor Cuoricino. The energy resolution (FWHM) in the region of interest is 5.7 keV, and with one year of live time the half-life sensitivity is expected to surpass Cuoricino's lower bound.
arXivarXiv · · February 5, 2014
0
118
The 4 K outer cryostat for the CUORE experiment: construction and quality control
F. AlessandriaM. BiassoniG. CerutiA. ChiariniM. ClemenzaO. CremonesiV. DatskovS. DossenaM. FaverzaniE. FerriA. NucciottiM. Perego  +4
This paper describes the construction and validation of the outer cryostat for the CUORE experiment, a large cryogen-free shell designed to host the dilution refrigerator and bolometers in a low-radioactivity environment. The three vessels forming the outer shell were produced and delivered to the Gran Sasso underground laboratories in July 2012. The authors detail the production techniques and the quality control tests performed at the production site during that year.
arXivarXiv · · June 6, 2013
0
20
Validation of techniques to mitigate copper surface contamination in CUORE
F. AlessandriaR. Ardito…V. Datskov
The CUORE experiment faces background from copper surface contamination, which mimics the neutrinoless double-beta decay signal. This paper validates three mitigation techniques using a dedicated test apparatus. The achieved contamination levels below $10^{-7}$–$10^{-8}$ Bq/cm² for $^{238}$U and $^{232}$Th would yield a projected background of 0.02–0.03 counts/keV/kg/y in the region of interest, confirming that the techniques can meet CUORE's stringent radiopurity requirements.
arXivarXiv · · October 3, 2012
0
125
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
Cuore CollaborationF. Alessandria…V. Datskov
The paper reports a search for 14.4 keV solar axions from the Fe-57 M1 transition using the axio-electric effect in TeO2 bolometers. With 43.65 kg d of CUORE test data, an upper limit of 0.63 c kg⁻¹ d⁻¹ (95% C.L.) was set, yielding a lower bound on the Peccei-Quinn energy scale fa ≥ 0.76 × 10⁶ GeV for a flavor-singlet axial vector matrix element S = 0.55, with bounds given for 0.15 < S < 0.55.
arXivarXiv · · September 13, 2012
0
63
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
F. AlessandriaR. Ardito…V. Datskov
Using 19.4 days of data from four 750~g TeO$_2$ bolometers, a new analysis technique lowered the energy threshold to about 3~keV in three detectors. The measured background rate falls from 25~cpd/keV/kg at 3~keV to 2~cpd/keV/kg at 25~keV. An unexplained 4.7~keV peak is confirmed by reanalysis of 62.7~kg·days of CUORICINO data. Expected sensitivities of CUORE-0 and CUORE to a WIMP annual modulation signal are reported.
arXivarXiv · · September 12, 2012
0
Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay
F. AlessandriaR. Ardito…V. Datskov
This paper evaluates CUORE's sensitivity and discovery potential for neutrinoless double-beta decay. Computing sensitivity for various background scenarios, the authors find that with a background rate of $10^{-2}$ cts/(keV kg y) and 5 years of live time, the 1-sigma half-life sensitivity is $T_{1/2}(1\sigma) = 1.6 \times 10^{26}$ y, probing effective Majorana neutrino masses down to 40-100 meV. The 90% C.L. sensitivity is $T_{1/2}(1.64\sigma) = 9.5 \times 10^{25}$ y. This range is compared with the claimed observation in $^{76}$Ge and oscillation-based neutrino mass parameter space.
arXivarXiv · · September 2, 2011
0
21
Hadronic Calibration of the ATLAS Liquid Argon End-Cap Calorimeter in the Pseudorapidity Region 1.6 < |eta| < 1.8 in Beam Tests
C. CojocaruJ. PinfoldJ. SoukupM. VincterV. DatskovA. FedorovS. GolubykhN. JavadovV. KalinnikovS. KakurinM. KazarinovV. Kukhtin  +104
This paper presents a hadronic calibration of the ATLAS liquid argon end-cap calorimeter for the pseudorapidity region $1.6 < |\eta| < 1.8$, using beam test data from the CERN SPS with electrons, muons, and pions in the energy range 6–200 GeV. A weighting ansatz, following the ATLAS hadronic calibration proposal, is applied to the measured signals. The intercalibration constants and performance are detailed, and the results are compared with GEANT 3 and GEANT 4 Monte Carlo simulations.
arXivarXiv · · July 2, 2004
0
Frequent collaborators
M. Sisti (11)
M. Biassoni (11)
M. Clemenza (11)
O. Cremonesi (11)
E. Ferri (11)
A. Nucciotti (11)
E. Previtali (11)
L. Taffarello (11)
O. Azzolini (10)
M. Balata (10)
G. Bari (10)
J. Beeman (10)