MCP
XD

X. Defay

32 papers in the library

Papers

30
Estimating cosmogenic backgrounds in nEXO at SNOLAB using Geant4 and FLUKA
R. RossS. Al Kharusi…X. Defay
The nEXO experiment searches for neutrinoless double beta decay in $^{136}$Xe using a five-tonne liquid xenon TPC. This paper estimates its cosmogenic background rate at the underground SNOLAB site, comparing Geant4 and FLUKA Monte Carlo simulations of muon-induced spallation and neutron reactions. Only $^{137}$Xe, from neutron capture on xenon, is concerning. The authors devise a veto strategy achieving 92% rejection of $^{137}$Xe with under 1 day dead time per 10 years.
arXivarXiv · · October 31, 2026
0
0
Characterization of CRYO ASIC for charge readout in the nEXO experiment
Z. LiM. Yu…X. Defay
This work characterizes the CRYO ASIC, a cryogenic charge-readout chip designed to operate directly in liquid xenon (LXe) for the nEXO neutrinoless double beta decay experiment, thereby minimizing input capacitance and pick-up noise. Tested on an auxiliary printed circuit board in a cryogenic chamber and a dedicated LXe test stand, the ASICs achieved the desired performance at LXe temperatures, with gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration via an on-chip pulser. Boiling from chip heat dissipation was mitigated by operating above ~0.1 MPa, and measured in-LXe noise agreed with simulation, indicating the $150~e^-$ design requirement can be met, establishing the CRYO ASIC as a viable low-noise in-LXe solution for nEXO.
arXivarXiv · · December 11, 2025
0
1
Performance of a Large Area Photon Detector For Rare Event Search Applications
CPD CollaborationC. W. FinkS. L. WatkinsT. AramakiP. L. BrinkJ. CamilleriX. DefayS. GanjamYu. G. KolomenskyR. MahapatraN. MirabolfathiW. A. Page  +6
This paper presents a large-area Cryogenic PhotoDetector (CPD) for rare event searches, consisting of a 45.6 cm^2, 1-mm-thick Si wafer instrumented with a distributed network of QETs (superconducting $T_c=41.5$ mK). The central contribution is an experimental characterization showing a baseline energy resolution of $\sigma_E = 3.86 \pm 0.04 (\mathrm{stat.})^{+0.23}_{-0.00} (\mathrm{syst.})$ eV (RMS), achieved through calibration with a collimated $^{55}$Fe X-ray source. The noise equivalent power is $1\times10^{-17}$ W/$\sqrt{\mathrm{Hz}}$ in a 2.7 kHz bandwidth, with an expected timing resolution of $\sigma_t = 2.3$ $\mu$s for 5$\sigma_E$ events.
arXivarXiv · · September 29, 2020
0
Description of CRESST-III Data
CRESST CollaborationA. H. AbdelhameedG. AngloherP. BauerA. BentoE. BertoldoC. BucciL. CanonicaA. D'AddabboX. DefayS. Di LorenzoA. Erb  +38
The paper describes the public release and usage of CRESST-III data from the best-performing detector module, which achieved a 30.1 eV nuclear recoil threshold over nearly two years of operation. Using this data, the collaboration set constraints on spin-dependent and spin-independent dark matter-nucleon scattering cross-sections for dark matter masses down to 160 MeV/c$^2$. The event energies after data selection and within the acceptance region are published.
arXivarXiv · · May 17, 2019
0
24
First results from the CRESST-III low-mass dark matter program
CRESST CollaborationA. H. AbdelhameedG. AngloherP. BauerA. BentoE. BertoldoC. BucciL. CanonicaA. D'AddabboX. DefayS. Di LorenzoA. Erb  +38
The CRESST-III experiment reports a nuclear recoil threshold of 30.1 eV using a 23.6 g CaWO$_4$ crystal operated as a cryogenic scintillating calorimeter at LNGS. Both the phonon/heat signal and scintillation light are measured with transition edge sensors at ~15 mK. The combination of these sensors with the light element oxygen in the target yields sensitivity to dark matter particle masses as low as 160 MeV/c$^2$.
arXivarXiv · · March 31, 2019
0
870
First results on sub-GeV spin-dependent dark matter interactions with 7^{7}Li
A.H. AbdelhameedG. AngloherP. BauerA. BentoE. BertoldoC. BucciL. CanonicaA. D'AddabboX. DefayS. Di LorenzoA. ErbF. v. Feilitzsch  +44
Operating a prototype Li$_2$MoO$_4$ cryogenic detector in an above-ground laboratory, we set competitive limits on spin-dependent dark matter interactions with protons and neutrons for dark matter masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$, demonstrating the potential of lithium as a target for low-mass dark matter searches.
arXivarXiv · · February 20, 2019
0
Limits on Dark Matter Effective Field Theory Parameters with CRESST-II
G. AngloherP. BauerA. BentoE. BertoldoC. BucciL. CanonicaA. D'AddabboX. DefayS. Di LorenzoA. ErbF. v. FeilitzschN. Ferreiro Iachellini  +33
Using data from CRESST-II, a direct dark matter search experiment, the authors re-analyze observed nuclear recoil events within an effective field theory (EFT) framework instead of the standard spin-independent or spin-dependent models. This approach yields improved exclusion limits on several EFT coupling constants, particularly for dark matter particle masses below 3–4 GeV, probing the low-mass region more effectively than previous analyses.
arXivarXiv · · September 11, 2018
0
43
A prototype detector for the CRESST-III low-mass dark matter search
R. StraussG. AngloherP. BauerX. DefayA. ErbF.v. FeilitzschN. Ferreiro IachelliniR. HampfD. HauffM. KieferJ.-C. LanfranchiA. Langenkämper  +19
The CRESST-III experiment, targeting low-mass dark matter, uses scintillating CaWO$_4$ cryogenic detectors. This paper presents a novel active detector holder that improves background discrimination. A 24g prototype achieved a nuclear-recoil energy threshold of $E_{th}=(190.6\pm5.2)$eV above ground, projecting $\sim$50eV in the low-noise CRESST cryostat—the lowest reported for direct dark matter searches. Ten such modules are installed for CRESST-III phase 1, potentially enhancing sensitivity to dark matter particles down to $\sim$0.1GeV/c$^2$.
arXivarXiv · · February 23, 2018
0
51
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaborationF. PetriccaG. AngloherP. BauerA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. Gorla  +34
The CRESST-III experiment, using cryogenic CaWO$_4$ calorimeters at Gran Sasso, reports preliminary Phase 1 results that extend direct dark-matter search sensitivity to sub-GeV/$c^2$ masses. Building on CRESST-II's leading reach below 1.7\,GeV/$c^2$, the optimized detectors measure both phonon and light signals from nuclear recoils, with the stated goal of further probing the low-mass region with unprecedented sensitivity.
arXivarXiv · · November 21, 2017
0
157
Search for low-mass Dark Matter with the CRESST Experiment
H. KluckG. AngloherP. BauerA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. Gütlein  +33
The CRESST experiment searches for dark matter using cryogenic CaWO$_4$ crystals. Its latest results from CRESST-II phase 2 set leading limits on the spin-independent DM-nucleon cross section for DM masses below 1 GeV/c$^2$, and exclude new parameter space for dark photons with masses between 300 eV/c$^2$ and 700 eV/c$^2$. The ongoing CRESST-III phase 1 operates ten upgraded 24 g detectors with improved background suppression and a lower detection threshold, aiming to extend sensitivity to lower DM masses.
arXivarXiv · · November 3, 2017
0
6
Performance of a CRESST-II Detector Module with True 4π4π-veto
G. AngloherP. BauerA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. GütleinD. Hauff  +33
The paper reports a CRESST-II detector module that uses a large, beaker-shaped silicon light absorber (~60 cm²) to replace the conventional design, improving the light-channel signal height by a factor of 2.5. Combined with a large carrier crystal, this forms a true 4π veto system that can tag external backgrounds, addressing both light-channel performance and background rejection in cryogenic bolometers for rare-event searches.
arXivarXiv · · August 4, 2017
0
4
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
G. AngloherP. BauerA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. GütleinD. Hauff  +35
A 0.5 g sapphire cryogenic calorimeter operated above ground achieved an energy threshold of $E_{th}=(19.7\pm 0.9)$ eV, an order of magnitude lower than previous results. This enables a new direct search for dark matter particles with masses below 1 GeV/c$^2$. Despite high background, the detector set the first exclusion limit on spin-independent dark matter-nucleon cross section for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
arXivarXiv · · July 21, 2017
0
280
Silicon PIN diodes as Neganov-Trofimov-Luke cryogenic light detectors
X. DefayE. MondragonJ.-C. LanfranchiA. LangenkamperA. MunsterW. PotzelS. SchonertS. WawocznyM. Willers
The paper presents a cryogenic light detector that improves charge collection by optimizing the electric field configuration in a silicon PIN diode operating under the Neganov-Trofimov-Luke effect (NTLE). The NTLE amplifies the phonon signal from particle interactions by drifting photogenerated electrons and holes in an electric field, yielding a high-sensitivity photon detector for rare event searches. The key contribution is the optimized electric field design that enhances charge collection within the absorber.
arXivarXiv · · July 17, 2017
0
5
Low-Temperature Relative Reflectivity Measurements of Reflective and Scintillating Foils used in Rare Event Searches
A. LangenkämperA. UlrichX. DefayF. v. FeilitzschJ.-C. LanfranchiE. MondragónA. MünsterC. OppenheimerW. PotzelS. RothS. SchönertH. Steiger  +4
This work measures the relative reflectivity of three multilayer polymer foils (VM2000, VM2002, Vikuiti) used in the CRESST dark matter experiment's phonon-light technique to enhance light collection and veto backgrounds. A dedicated setup using a CCD camera measured the intensity of a light beam reflected off each foil at 300 K and 20 K; the ratio of these intensities gives the relative reflectivity change. The measurements show no significant change in reflectivity with temperature for any of the foils, supporting their use in cryogenic rare-event searches.
arXivarXiv · · March 21, 2017
0
10
Description of CRESST-II data
G. AngloherP. BauerA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. GütleinD. Hauff  +38
The CRESST-II Phase 2 experiment publishes energies of events from two detector modules used for direct dark-matter searches, collected over about two years (July 2013–August 2015). These data sets yielded world-leading limits on the spin-independent elastic scattering cross section of dark matter particles off nuclei. The release includes events within the acceptance regions for dark-matter searches and the electron-recoil band, enabling studies of interactions with CaWO$_4$ electrons. The document provides cut-survival probabilities for model comparisons.
arXivarXiv · · January 27, 2017
0
17
Dark-Photon Search using Data from CRESST-II Phase 2
G. AngloherP. BauerA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. GütleinD. Hauff  +31
Dark photons are hypothetical dark-matter candidates that interact with electrons via kinetic mixing with standard-model photons. This work sets new constraints on that mixing using CRESST-II Phase 2 data (52\,kg-days exposure before cuts). The bounds improve previous limits for dark-photon masses between 0.3 and 0.7\,keV/c$^2$.
arXivarXiv · · December 22, 2016
0
20
Direct Dark Matter Search with the CRESST II Experiment
J SchieckG AngloherA BentoC BucciL CanonicaX DefayA ErbF v FeilitzschN Ferreiro IachelliniP GorlaA GuetleinD Hauff  +31
The CRESST II experiment, located at the Gran Sasso laboratory, searches for low-mass dark matter particles by measuring their elastic scattering with ordinary matter. Using an improved detector setup with enhanced radio-purity and background rejection, combined with a dedicated low-threshold analysis of a single conventional module, the experiment sets the most stringent direct-detection limit in the mass region below 1.8 GeV/$c^2$. The paper also discusses the performance expectations for new, smaller CRESST-type detectors for the next data-taking phase.
arXivarXiv · · November 7, 2016
0
19
New Limits on Double Electron Capture of 40^{40}Ca and 180^{180}W
G. AngloherM. BauerP. BauerI. BavykinaA. BentoC. BucciL. CanonicaC. CiemniakX. DefayG. DeuterA. ErbF. v. Feilitzsch  +44
Using 730 kg days of CRESST-II low-background data, this work sets new half-life limits on double electron capture for two isotopes at 90% confidence. For $^{40}$Ca, the limits are $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y; for $^{180}$W, they are $T_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y. These represent improvements of roughly 1.4 to 30 times over previous best limits, depending on the specific decay channel.
arXivarXiv · · April 28, 2016
0
18
Limits on momentum-dependent asymmetric dark matter with CRESST-II
G. AngloherA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. GütleinD. HauffJ. Jochum  +28
Using CRESST-II data, this paper constrains momentum-dependent asymmetric dark matter models where the interaction cross section scales with $q^2$, relevant for light dark matter ($\mathcal{O}(\mathrm{GeV/c^2})$). The low nuclear recoil energy threshold of 307 eV of the cryogenic $\mathrm{CaWO_4}$ detector rules out the previously proposed best-fit point of a 3 $\mathrm{GeV/c^2}$ particle with cross section $10^{-37} \mathrm{cm^2}$, which was motivated by helioseismology discrepancies.
arXivarXiv · · January 18, 2016
0
23
The CRESST Dark Matter Search - Status and Perspectives
CRESST CollaborationF. ReindlG. AngloherA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. Gütlein  +29
The CRESST collaboration reports results from its TUM40 detector, which uses a new upgraded holding scheme to veto backgrounds from surface alpha decays. With a low energy threshold of 0.6 keV and an unprecedented background level for CaWO$_4$ targets, TUM40 achieved the best overall performance in CRESST-II phase 2. A low-threshold analysis enabled the search for light dark matter particles below 3 GeV/c$^2$, a mass region previously inaccessible to other direct detection experiments.
arXivarXiv · · September 30, 2015
0
7
Cryogenic silicon detectors with implanted contacts for the detection of visible photons using the Neganov-Luke Effect
X. DefayE. MondragonM. WillersA. LangenkamperJ.-C. LanfranchiA. MunsteraA. ZollerS. WawocznyH. SteigerF. HitzlerC. BruhnS. Schonert  +2
A novel cryogenic silicon detector for visible photons uses the Neganov-Luke effect to amplify the thermal signal by drifting photogenerated charge carriers in an electric field, but charge trapping degrades amplitude over time. The detector introduces an optimized electric field configuration designed to improve charge collection. First results demonstrate that this design reduces trapping, enabling more stable amplification and a lower energy threshold for applications in dark matter and neutrino experiments.
arXivarXiv · · September 21, 2015
0
Results on light dark matter particles with a low-threshold CRESST-II detector
CRESST CollaborationG. AngloherA. BentoC. BucciL. CanonicaX. DefayA. ErbF. v. FeilitzschN. Ferreiro IachelliniP. GorlaA. GütleinD. Hauff  +29
The CRESST-II experiment's low-threshold CaWO$_4$ detector, operating cryogenically, achieved a 307 eV nuclear recoil threshold from 52 kg live days of blind analysis. This substantially enhanced sensitivity to low-mass dark matter particles via elastic scattering, extending direct-detection reach into the sub-GeV/c$^2$ region. The result demonstrates that energy threshold, not exposure alone, is the key parameter for probing light dark matter.
arXivarXiv · · September 4, 2015
0
836
Measurement of the Beam-Recoil Polarization in Low-Energy Virtual Compton Scattering from the Proton
L. DoriaP. Janssens…X. Defaÿ
The double-polarization observable $P_{LT}^\perp$ in the reaction $\vec{e}p \rightarrow e'\vec{p'}\gamma{}$ was measured at $Q^2=0.33\,(\text{GeV}/c)^2$ using an 855 MeV polarized electron beam at MAMI and a recoil proton polarimeter. Applying the low-energy theorem for Virtual Compton Scattering, the structure function is extracted for the first time, yielding $(-15.4 \pm 3.3 (\text{stat.})^{+1.5}_{-2.4} (\text{syst.}))\,\text{GeV}^{-2}$. This result provides a previously unmeasured linear combination of the generalized polarizabilities of the proton.
arXivarXiv · · May 22, 2015
0
16
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMSEDELWEISS Collaborations…X. Defay
The CDMS and EDELWEISS collaborations combined their direct dark-matter searches using cryogenic germanium detectors, yielding a total 614 kg.d equivalent exposure. They employed a simple combination method before data exchange. For spin-independent WIMP-nucleon interactions, a cross-section of $3.3 \times 10^{-44}$ cm$^2$ is excluded at 90% CL for a 90 GeV/c$^2$ WIMP mass, where the analysis is most sensitive. At higher masses, the combined limit improves individual limits by a factor of 1.6 above 700 GeV/c$^2$.
arXivarXiv · · May 17, 2011
0
127
Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
EDELWEISS CollaborationE. Armengaud…X. Defay
The EDELWEISS-II experiment operated an array of ten 400-g cryogenic germanium detectors with interleaved electrodes at the Laboratoire Souterrain de Modane to search for WIMP dark matter. The interleaved electrode geometry enabled efficient rejection of gamma-induced and near-surface backgrounds. Over 384 kg.d of effective exposure, five nuclear recoil candidates above 20 keV were observed against an estimated background of 3.0 events. For spin-independent WIMP-nucleon interactions, a cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% CL for a WIMP mass of 85 GeV. New constraints on inelastic scattering models are also reported.
arXivarXiv · · March 21, 2011
0
380
A detection system to measure muon-induced neutrons for direct Dark Matter searches
V.Yu. KozlovE. Armengaud…X. Defay
This paper presents a neutron detector designed to measure muon-induced neutrons, a key background for direct Dark Matter searches. The system uses 1 m³ of Gd-loaded scintillator, operating in the Laboratoire Souterrain de Modane and linked to the muon veto of the EDELWEISS-II experiment. Installed in autumn 2008, it passed commissioning tests and has achieved a count rate of roughly one muon-induced neutron per day during continuous data-taking.
arXivarXiv · · June 15, 2010
0
26
Monitoring of the thermal neutron flux in the LSM underground laboratory
S. RozovE. Armengaud…X. Defay
This paper reports precise measurements of the thermal neutron flux at the LSM underground laboratory, using a mobile $^3$He proportional counter detector. The average flux near the EDELWEISS-II experiment is $\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec/cm$^{2}$. The key finding is the first observation that the point-to-point flux varies by more than a factor of two within the laboratory.
arXivarXiv · · January 25, 2010
0
24
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
E. ArmengaudC. Augier…X. Defay
The EDELWEISS-II collaboration reports a direct WIMP search using ten 400 g Ge cryogenic detectors with interleaved electrodes to reject near-surface events. After 144 kg·d effective exposure, one nuclear recoil candidate above 20 keV is observed. This yields a 90% CL upper limit on the spin-independent WIMP–nucleon cross-section of $1.0\times 10^{-7}$ pb at a WIMP mass of 80 GeV/$c^2$, demonstrating the detectors’ background-rejection capability in a running experiment.
arXivarXiv · · December 4, 2009
0
123
A new high-background-rejection dark matter Ge cryogenic detector
A. BroniatowskiX. DefayE. ArmengaudL. BergeA. BenoitO. BesidaJ. BlumerA. ChantelauzeM. ChapellierG. ChardinF. CharlieuxS. Collin  +31
This paper presents a cryogenic germanium detector for dark matter searches that uses the coplanar grid technique to localize events, enabling improved background discrimination. Prototype tests in the EDELWEISS II setup at Modane show rejection of low-energy $\beta$ particles approaching $10^5$. This efficiency allows investigation of WIMP-nucleon cross-sections beyond $10^{-8}$ pb, as envisioned for the EURECA one-ton detector project.
arXivarXiv · · May 6, 2009
0
128
Proceedings of the 1st International Workshop "Radiopure Scintillators for EURECA" (RPScint'2008)
E. ArmengauM. Bauer…X. Defay
This proceedings volume reports on the 2008 RPSCINT workshop, which gathered physicists, chemists, and crystal experts to address the radiopurity and scintillation requirements of low-count-rate experiments, particularly for the EURECA project. The central focus is the selection, purification, and testing of scintillating materials, including crystal growth and handling, as well as the development of new materials. Contributions cover these topics, aiming to enable the required sensitivity.
arXivarXiv · · March 9, 2009
0
0
Frequent collaborators
H. Kluck (21)
W. Potzel (18)
M. Willers (18)
H. Kraus (17)
D. Hauff (16)
G. Angloher (15)
A. Bento (15)
A. Erb (15)
F. v. Feilitzsch (15)
N. Ferreiro Iachellini (15)
J. Jochum (15)
A. Münster (15)