Integrated tuning fork nanocavity optomechanical transducers with high
fMQM product and stress-engineered frequency tuning
This paper presents a monolithic cavity optomechanical transducer that replaces the common doubly-clamped Si$_3$N$_4$ nanobeam with a tuning fork geometry, achieving both high mechanical frequency and high quality factor. The device demonstrates a fundamental $f_{M}\approx29$ MHz and $Q_{M}\approx2.2\times10^5$, yielding an $f_{M}Q_{M}$ product of 6.35$\times10^{12}$ Hz, comparable to the best room-temperature results. Stress engineering through clamp design triples the tuning fork's stress relative to the residual film stress, increasing $f_{M}$ by 1.5 times. Simulations indicate the design reduces clamping, thermoelastic, and intrinsic material damping losses.