MCP
YJ

Yohan Jun

19 papers in the library · Same-name authors told apart using DBLP

Papers

19
Multi-echo AxCaliberSMT: Mapping effective axon radius from restricted diffusion and radius-dependent intra-axonal T2
Kwok-Shing ChanYohan JunAneri BhattBerkin BilgicSusie Y. HuangHong-Hsi Lee
Multi-echo AxCaliberSMT (ME-AxCaliberSMT) combines cylinder-restricted diffusion, whose contrast scales with $r^4$ and thus favours large axons, with intra-axonal $R_2$ proportional to $1/r$ to broaden the dynamic range of axon radius estimation in human white matter. Spherical-mean diffusion-relaxation signals are modelled with histologically calibrated surface relaxation, and the two contrasts become comparable at a protocol-dependent transition radius (1.42 µm on Connectome 2.0, 1.85 µm on Cima.X), below which relaxation dominates. At SNR 40 it achieved normalised bias of $\pm$6%, where AxCaliberSMT overestimated small radii, and it was less sensitive to calibration errors than the diffusion-filtered $R_2$ model.
arXivarXiv · · November 13, 2026
0
Vendor-Agnostic Joint Relaxometry and Myelin Water Fraction Mapping with B1 and Motion Correction
Unay Dorken GallastegiShohei FujitaYohan JunAntoine Delattre-KlauserGian Franco PireddaTom HilbertCemre AriyurekEugene MilshteynShizhuo LiYuting ChenXingwang YongKwok-Shing Chan  +10
This paper introduces a vendor-agnostic MRI acquisition and reconstruction pipeline for joint mapping of T1, T2, and myelin water fraction. The method integrates dictionary-based multi-compartment fitting with retrospective motion correction using subspace reconstruction and self-navigation, eliminating the need for external motion tracking. It also includes rapid B1+ and B1- estimation. Simulations, phantom tests, and in vivo experiments across multiple scanner types demonstrate accuracy and consistency, particularly for short T2 components associated with myelin, making the package suitable for multi-site neuroimaging studies.
arXivarXiv · · August 7, 2026
0
0
MWF-MIMOSA for efficient simultaneous relaxometry and myelin water fraction mapping
Yuting ChenYohan JunHyeong-Geol ShinShizhuo LiShohei FujitaXingwang YongJiye KimJongho LeeGian Franco PireddaTom HilbertAneri BhattSusie Y. Huang  +6
This paper introduces MWF-MIMOSA, a method for efficient simultaneous relaxometry and myelin water fraction (MWF) mapping. It uses multi-contrast, multi-slice zero-shot self-supervised learning to reconstruct whole-brain complex-valued images, and a multilayer perceptron trained within a GPU-accelerated framework to replace computationally intensive Bloch simulations, achieving a >100-fold speed-up in MWF estimation. The method produces T1, T2, T2* maps, magnetic susceptibility source separation, and MWF maps in 5 minutes at 1 mm isotropic resolution and 10 minutes at 0.7 mm, with high correlation to established approaches.
arXivarXiv · · July 31, 2026
0
0
FINDER: Zero-Shot Field-Integrated Network for Distortion-free EPI Reconstruction in Diffusion MRI
Namgyu HanSeong Dae YunChaeeun LimSunghyun SeokSunju KimYoonhwan KimYohan JunTae Hyung KimBerkin BilgicJaejin Cho
FINDER is a zero-shot, scan-specific framework for EPI reconstruction in diffusion MRI that jointly optimizes the underlying image and the $B_0$ field map. It uses a physics-guided unrolled network with dual-domain denoisers for data consistency, coupled with an Implicit Neural Representation modeling the off-resonance field as a continuous function. Alternating minimization disentangles geometric distortions from anatomy, achieving superior fidelity and image quality without training data.
arXivarXiv · · March 27, 2026
0
0
Omni-QALAS: Optimized Multiparametric Imaging for Simultaneous T1, T2 and Myelin Water Mapping
Shizhuo LiUnay Dorken GallastegiShohei FujitaYuting ChenPengcheng XuYangsean ChoiBorjan GagoskiHuihui YeHuafeng LiuBerkin BilgicYohan Jun
Omni-QALAS jointly optimizes sequence parameters—flip angles, T2 preparation durations, and recovery gaps—via a self-supervised multilayer perceptron trained to minimize a Cramér-Rao bound-based loss under scan-time constraints. Targeting white matter, gray matter, and myelin water, the optimized sequence reduces readouts from six to five and total scan time by nearly one minute. It enables simultaneous T1, T2, and myelin water fraction (MWF) mapping at 1 mm isotropic resolution in 3 minutes 30 seconds, with improved accuracy over the prior MWF-QALAS method.
arXivarXiv · · October 15, 2025
0
Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner
Quentin UhlTommaso PavanJulianna GeroldKwok-Shing ChanYohan JunShohei FujitaAneri BhattYixin MaQiaochu WangHong-Hsi LeeSusie Y. HuangBerkin Bilgic  +1
To accelerate the NEXI diffusion MRI protocol for gray matter microstructure, an XAI framework (XGBoost, SHAP, Recursive Feature Elimination) trained on synthetic signals identified an optimal 8-feature subset that reduced scan time from 27 to 14 minutes on the Connectome 2.0 scanner. In vivo validation in seven participants showed robust parameter estimates and test-retest reproducibility, converging to the CRLB theoretical optimum without requiring complex analytical Jacobians, and outperforming two heuristic sampling strategies.
arXivarXiv · · September 11, 2025
0
3
MIMOSA: Multi-parametric Imaging using Multiple-echoes with Optimized Simultaneous Acquisition for highly-efficient quantitative MRI
Yuting ChenYohan JunAmir HeydariXingwang YongJiye KimJongho LeeHuafeng LiuHuihui YeBorjan GagoskiShohei FujitaBerkin Bilgic
MIMOSA is a new sequence that extends 3D-QALAS by combining 3D turbo FLASH and multi-echo gradient echo acquisition with a spiral-like Cartesian trajectory. It enables highly efficient simultaneous quantification of T1, T2, T2*, proton density, and source separation QSM. Simulations and phantom experiments show improved accuracy over 3D-QALAS. In vivo, whole-brain 1 mm isotropic multi-parametric maps are obtained in 3 minutes at 3T, with R = 11.8 acceleration preserving parameter estimation accuracy and high scan-rescan reproducibility.
arXivarXiv · · August 13, 2025
0
5
Multishot Dual Polarity GRAPPA: Robust Nyquist Ghost Correction for multishot EPI
Yuancheng JiangYohan JunQiang LiuWen ZhongYogesh RathiHua GuoBerkin Bilgic
This work develops multishot dual-polarity GRAPPA (msDPG), a method for correcting Nyquist ghosts in multishot echo-planar imaging (EPI). By extending the dual-polarity GRAPPA concept, msDPG uses tailored kernels to model high-order phase differences between the two EPI readout polarities that linear phase correction cannot fully address. The method also incorporates advanced regularizers for inter-shot phase variation and a calibration refinement step. On scanners with high-performance gradients or ultra-high fields, msDPG achieved a ghost-to-signal ratio reduction of over 50% compared to linear phase correction, enabling high-fidelity submillimeter diffusion imaging.
arXivarXiv · · July 24, 2025
0
5
A Tutorial on MRI Reconstruction: From Modern Methods to Clinical Implications
Tolga ÇukurSalman U. H. DarValiyeh Ansarian NezhadYohan JunTae Hyung KimShohei FujitaBerkin Bilgic
This tutorial surveys MRI reconstruction, which accelerates acquisitions by incorporating prior information to regularize the ill-posed inverse problem. It covers classical methods with explicit hand-crafted priors and deep learning approaches that combine learned and crafted priors, alongside translational aspects and clinical implications. The tutorial is accompanied by a Python toolbox demonstrating select methods.
arXivarXiv · · July 22, 2025
0
23
PRIME: Phase Reversed Interleaved Multi-Echo acquisition enables highly accelerated distortion-free diffusion MRI
Yohan JunQiang LiuTing GongJaejin ChoShohei FujitaXingwang YongCongyu LiaoMarianna E SchmidtShahin NasrCamilo JaimesMichael S GeeSusie Y Huang  +4
The paper introduces PRIME (Phase Reversed Interleaved Multi-Echo Acquisition), a pulse sequence that inserts additional echoes without prolonging TR when gSlider volumetric encoding is used. The first echo acquires high-resolution diffusion-weighted imaging, while subsequent echoes provide high-fidelity field maps for distortion correction, shot-to-shot phase navigation, motion navigation, or high-resolution diffusion relaxometry. Demonstrating in-plane acceleration up to 5-fold with 2D partial Fourier, PRIME enabled distortion-free dMRI at 490-μm isotropic resolution on a Connectome 2.0 scanner.
arXivarXiv · · September 11, 2024
0
7
NLCG-Net: A Model-Based Zero-Shot Learning Framework for Undersampled Quantitative MRI Reconstruction
Xinrui JiangYohan JunJaejin ChoMengze GaoXingwang YongBerkin Bilgic
NLCG-Net directly estimates T1 and T2 maps from undersampled k-space data by integrating a nonlinear conjugate gradient solver with a U-Net regularizer trained in a scan-specific, zero-shot manner. This model-based approach replaces the conventional two-step reconstruction-then-fitting pipeline, reducing error propagation. Experiments on T2 and T1 mapping show that NLCG-Net achieves higher fidelity than subspace reconstruction at high acceleration factors.
arXivarXiv · · January 22, 2024
0
0
Improved Multi-Shot Diffusion-Weighted MRI with Zero-Shot Self-Supervised Learning Reconstruction
Jaejin ChoYohan JunXiaoqing WangCaique KobayashiBerkin Bilgic
Zero-MIRID is a zero-shot self-supervised learning method for reconstructing multi-shot echo-planar imaging (msEPI) diffusion MRI. It jointly reconstructs msEPI data by incorporating CNN denoisers in both k-space and image-space, and uses virtual coils to improve reconstruction conditioning. The network is trained on the target data alone by splitting sampled data into three groups. In an in-vivo experiment, zero-MIRID outperformed the state-of-the-art parallel imaging method, addressing phase variation challenges in msEPI.
arXivarXiv · · August 9, 2023
0
15
Zero-DeepSub: Zero-Shot Deep Subspace Reconstruction for Rapid Multiparametric Quantitative MRI Using 3D-QALAS
Yohan JunYamin ArefeenJaejin ChoShohei FujitaXiaoqing WangP. Ellen GrantBorjan GagoskiCamilo JaimesMichael S. GeeBerkin Bilgic
Zero-DeepSub combines a low-rank subspace model with a zero-shot deep-learning reconstruction to improve the fidelity of T1 and T2 mapping from 3D-QALAS time-series data. The method reduces bias and noise compared to conventional QALAS, achieves robust performance at up to 9-fold acceleration, and enables whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 minutes of scan time.
arXivarXiv · · July 4, 2023
0
35
SDC-UDA: Volumetric Unsupervised Domain Adaptation Framework for Slice-Direction Continuous Cross-Modality Medical Image Segmentation
Hyungseob ShinHyeongyu KimSewon KimYohan JunTaejoon EoDosik Hwang
Recent advances in deep learning-based medical image segmentation studies achieve nearly human-level performance in fully supervised manner. However, acquiring pixel-level expert annotations is extremely expensive and laborious in medical imaging fields. Unsupervised domain adaptation (UDA) can alleviate this problem, which makes it possible to use annotated data in one imaging modality to train a network that can successfully perform segmentation on target imaging modality with no labels. In this work, we propose SDC-UDA, a simple yet effective volumetric UDA framework for Slice-Direction Continuous cross-modality medical image segmentation which combines intra- and inter-slice self-attentive image translation, uncertainty-constrained pseudo-label refinement, and volumetric self-training. Our method is distinguished from previous methods on UDA for medical image segmentation in that it can obtain continuous segmentation in the slice direction, thereby ensuring higher accuracy and potential in clinical practice. We validate SDC-UDA with multiple publicly available cross-modality medical image segmentation datasets and achieve state-of-the-art segmentation performance, not to mention the superior slice-direction continuity of prediction compared to previous studies.
CVFCVF · June 2023
0
SDC-UDA: Volumetric Unsupervised Domain Adaptation Framework for Slice-Direction Continuous Cross-Modality Medical Image Segmentation
Hyungseob ShinHyeongyu KimSewon KimYohan JunTaejoon EoDosik Hwang
SDC-UDA is a volumetric unsupervised domain adaptation framework for cross-modality medical image segmentation. It combines intra- and inter-slice self-attentive image translation, uncertainty-constrained pseudo-label refinement, and volumetric self-training. The key contribution is achieving continuous segmentation in the slice direction, which improves accuracy and clinical applicability. Experiments on multiple public datasets show state-of-the-art performance and superior slice-direction continuity compared to prior methods.
arXivarXiv · · May 18, 2023
0
86
SSL-QALAS: Self-Supervised Learning for Rapid Multiparameter Estimation in Quantitative MRI Using 3D-QALAS
Yohan JunJaejin ChoXiaoqing WangMichael GeeP. Ellen GrantBerkin BilgicBorjan Gagoski
SSL-QALAS is a self-supervised learning method that reconstructs T1, T2, proton density, and inversion efficiency maps from 3D-QALAS MRI measurements without an external dictionary or labeled training data. It achieves rapid reconstruction (within 10 seconds using a pre-trained model) and fast scan-specific fine-tuning (within 15 minutes). Phantom experiments show strong linear agreement with reference T1 and T2 values, comparable to dictionary matching. In vivo, SSL-QALAS produces maps similar to dictionary matching, demonstrating its potential for rapid, dictionary-free quantitative MRI.
arXivarXiv · · February 28, 2023
0
21
COSMOS: Cross-Modality Unsupervised Domain Adaptation for 3D Medical Image Segmentation based on Target-aware Domain Translation and Iterative Self-Training
Hyungseob ShinHyeongyu KimSewon KimYohan JunTaejoon EoDosik Hwang
COSMOS is a self-training-based unsupervised domain adaptation framework for 3D medical image segmentation validated on vestibular schwannoma and cochlea segmentation from T2 MRI. It uses a target-aware contrast conversion network to translate annotated T1 MRI to pseudo T2 MRI, preserving anatomical features, then iteratively refines pseudo-labels with unlabeled data. This approach achieves mean Dice scores of 0.871 for VS and 0.842 for cochlea, winning the crossMoDA 2021 challenge.
arXivarXiv · · March 30, 2022
0
50
Self-Training Based Unsupervised Cross-Modality Domain Adaptation for Vestibular Schwannoma and Cochlea Segmentation
Hyungseob ShinHyeongyu KimSewon KimYohan JunTaejoon EoDosik Hwang
This work proposes a self-training based unsupervised framework for segmenting vestibular schwannoma and cochlea on high-resolution T2 MRI without annotations. It first converts contrast-enhanced T1 scans (with labels) to synthetic T2 scans via VS-preserving conversion, trains a segmentation model on them, infers pseudo-labels on real unlabeled T2 scans, and then retrains on combined data (real T2 with pseudo-labels and synthetic T2 with true labels). The method achieves mean Dice of 0.8570 (VS) and 0.8446 (cochlea) on the CrossMoDA2021 validation set, outperforming most other approaches.
arXivarXiv · · September 22, 2021
0
0
Results of the 2020 fastMRI Challenge for Machine Learning MR Image Reconstruction
Matthew J. MuckleyBruno RiemenschneiderAlireza RadmaneshSunwoo KimGeunu JeongJingyu KoYohan JunHyungseob ShinDosik HwangMahmoud MostaphaSimon ArberetDominik Nickel  +11
The 2020 fastMRI challenge evaluated machine learning methods for reconstructing brain MR images from subsampled k-space data, using 7,299 clinical scans (894 held out for evaluation). Unlike the 2019 edition, radiologist assessment focused on pathology, and a new Transfer track tested models on data from unseen MRI scanners. Among 19 submissions, one team achieved the best structural similarity index and radiologist ratings. The analysis identified common failure modes, guiding future research.
arXivarXiv · · December 9, 2020
0
493
Frequent collaborators
Berkin Bilgic (14)
Shohei Fujita (8)
Borjan Gagoski (6)
Jaejin Cho (6)
Xingwang Yong (5)
Hyungseob Shin (5)
Dosik Hwang (5)
Kwok-Shing Chan (4)
Yuting Chen (4)
Hyeongyu Kim (4)
Sewon Kim (4)
Taejoon Eo (4)