MCP

Paper library

Updated daily
arXivarXiv is the preprint server for physics, mathematics, computer science and more, and supplies the most papers. OpenReviewOpenReview hosts submissions and public reviews for conferences such as ICLR and NeurIPS. ACL AnthologyACL Anthology collects conference and journal papers in computational linguistics. CVFCVF hosts papers from computer vision conferences such as CVPR and ICCV. bioRxivbioRxiv and medRxivmedRxiv host preprints in biology and medicine.
3.3M
Papers
23
Source
8
Disciplines
3 papers
Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose
Suryakant KaushikJakob ÖdénAlbin FredrikssonIuliana Toma-Dasu
This work extends a treatment planning system to optimize hypofractionated plans directly on equieffective dose, $EQD_{n_{ref}}$, so that an alternative regimen delivered in $n$ fractions remains equieffective with a reference fractionation for a specified biological endpoint, rather than requiring planners to manually adjust prescriptions and constraints. In three head and neck cases, prescriptions of 70 Gy and 54 Gy in 35 fractions were re-planned in 34, 32, 30, and 25 fractions with robust optimization of targets, spinal cord, and brainstem; all plans preserved target coverage and met mandatory OAR goals, with only small $EQD_{n_{ref}}$ deviations and $\alpha/\beta$ uncertainty causing the largest variation at 25 fractions.
arXivarXiv · · November 25, 2026
0
DosePET: An Open-Source Dataset with 2100 Radiation Dose Maps for PET/CT
Eleftherios TzanisAntonios TzortzakakisMichail E. Klontzas
DosePET is an open-source dataset of 2,100 patient-specific absorbed-dose maps produced by Monte Carlo simulation of public PET/CT examinations: 1,503 [18F]FDG studies from ENHANCE.PET and 369 [18F]PSMA-1007 plus 228 [68Ga]Ga-PSMA-11 studies from PSMA-PET-CT-Lesions, acquired at five institutions with seven scanner models. For each examination, the CT was resampled to the native PET grid to build a voxelized phantom, the quantitative PET image defined the radionuclide source, and transport was simulated with GATE 9.4, with organ and tissue masks from TotalSegmentator. Each study folder holds a NIfTI dose map integrated from scan time to infinity, 117 binary masks, a regional dosimetry report and simulation metadata, with Python tools for selective download and conversion to scan-time dose-rate or dose-per-decay maps.
arXivarXiv · · November 25, 2026
0
Monte Carlo-based secondary dose check platform for the world's first ultra-compact upright proton therapy system
Toghrul AlakbarzadeEmir Musa OlgunYuan James RaoBilly W LooAdam JohanssonYong YangMurat SurucuMehmet Burcin UnluSerdar Charyyev
This work develops and validates an independent TOPAS Monte Carlo secondary dose check for RayStation plans on the Mevion S250-FIT, the first ultra-compact upright proton therapy system. The nozzle, including its boron carbide and polycarbonate energy modulation system and adaptive aperture, was modeled and commissioned against integrated depth dose curves, in-air spot profiles, and dose per monitor unit at 12 energy settings, with agreement within 0.25 mm in range, 6.8% in spot full width at half maximum, and 1.3% in dose per monitor unit. An in-house converter, RayStation2TOPAS, then recalculates plans by reconstructing each pencil beam spot, each energy layer's aperture, and the seated patient's rotation. All 15 water phantom and 25 clinical plans passed the 5% point-dose tolerance and 3%/2mm gamma criteria (at least 90%), supporting patient-specific quality assurance.
arXivarXiv · · November 25, 2026
0
Date
November 25 Wed
M
T
W
T
F
S
S
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30