MCP
DB

D. Bishop

11 papers in the library

Papers

11
Innovative Oxide Transistor Satisfying Performance and Reliability Simultaneously by Understanding of Physics and Materials Properties
C.W. ChengJ. SmithP. SolomonR. WattersD. PiatekC. LavoieM. HopstakenL. GignacD. BishopB. KhanM. BrightSkyG. Gionta  +3
This paper presents an oxide semiconductor transistor that simultaneously achieves high performance and reliability by breaking the conventional constraint between the two. Guided by accumulation-mode physics and materials properties, the authors propose a new structure and process flow for a 10 nm InGaZnO$_4$ (IGZO) transistor. It demonstrates high on-current, extrinsic mobility of 20 cm$^2$V$^{-1}$s$^{-1}$, near-zero hysteresis, and only a 15 mV $V_t$ shift after 3 MV/cm positive-bias stress for 1000 s at room temperature.
arXivarXiv · · September 9, 2025
0
0
Decay Spectroscopy of 160^{160}Eu: Quasiparticle Configurations of Excited States and Structure of KπK^π=4+4^+ Band-heads in 160^{160}Gd
D. YatesR. Kruecken…D. Bishop
The paper reports high-statistics decay spectroscopy of $^{160}$Gd, populated via the $\beta$-decay of $^{160}$Eu, using the GRIFFIN spectrometer. Two new excited states, ten new transitions, and a revised 26.0(8) s half-life for the low-spin isomer of $^{160}$Eu are presented. The lifetimes of the two $K^\pi$=$4^+$ band-heads in $^{160}$Gd are measured for the first time, and their $\gamma$-$\gamma$ angular correlations and mixing ratios favor a hexadecapole phonon interpretation over a simple two-state mixing scenario.
arXivarXiv · · May 18, 2023
0
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
C. GalbiatiA. AbbaP. AgnesP. AmaudruzM. ArbaF. Ardellier-DesagesC. BadiaG. BatignaniG. BellaniG. BianchiD. BishopV. Bocci  +136
The Mechanical Ventilator Milano (MVM) is a novel ventilator designed for rapid mass production during the COVID-19 pandemic, addressing shortages of intensive therapy ventilators. It is an electro-mechanical equivalent of the Manley Ventilator, operating in pressure-controlled and pressure-supported modes. Using only off-the-shelf components, it requires compressed oxygen or medical air and electrical power. Initial prototype tests with a breathing simulator have been conducted; certification is ongoing.
arXivarXiv · · March 23, 2020
0
42
The GRIFFIN Facility for Decay-Spectroscopy Studies at TRIUMF-ISAC
A.B. GarnsworthyC.E. Svensson…D. Bishop
The GRIFFIN spectrometer is a high-efficiency gamma-ray detector array for decay spectroscopy at TRIUMF-ISAC, comprising sixteen Compton-suppressed clover-type HPGe detectors, ancillary systems, and a custom digital data acquisition system. This paper describes the facility's infrastructure, detectors, performance characteristics, and analysis techniques.
arXivarXiv · · September 18, 2018
0
70
In-beam internal conversion electron spectroscopy with the SPICE detector
M. MoukaddamJ. SmallcombeL.J. EvittsA.B. GarnsworthyC. AndreoiuG.C. BallJ. Berean-DutcherD. BishopC. BoltonR. Caballero-FolchM. ConstableD.S. Cross  +27
The SPICE detector, a permanent rare-earth magnetic lens coupled with a segmented lithium-drifted silicon detector, has been commissioned at TRIUMF's ISAC-II facility. It collects and directs internal conversion electrons from nuclear reactions. When combined with the TIGRESS $\gamma$-ray spectrometer, it enables simultaneous in-beam $\gamma$-ray and internal conversion electron spectroscopy using both stable and radioactive ion beams. The paper reports the device's technical aspects and initial performance.
arXivarXiv · · August 8, 2018
0
14
Design and Construction of the DEAP-3600 Dark Matter Detector
P.-A. AmaudruzM. BaldwinM. BatygovB. BeltranC. E. BinaD. BishopJ. BonattG. BoormanM. G. BoulayB. BroermanT. BromwichJ. F. Bueno  +97
DEAP-3600 is a single-phase liquid argon detector designed for direct dark matter search. Its projected sensitivity to spin-independent WIMP-nucleon scattering is $10^{-46}~\mathrm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a 3 tonne-year fiducial exposure. This paper details the detector's physical properties and construction.
arXivarXiv · · December 6, 2017
0
176
The GRIFFIN Data Acquisition System
A.B. GarnsworthyC.J. PearsonD. BishopB. ShawJ.K. SmithM. BowryV. BildsteinG. HackmanP.E. GarrettY. LinnJ.-P. MartinW.J. Mills  +1
The GRIFFIN data acquisition system, custom-designed for radioactive decay studies at TRIUMF-ISAC, achieves high-precision half-life and branching ratio measurements with uncertainties below 0.05%. It collects signals from high-purity germanium crystals at rates up to 50 kHz while preserving energy resolution, detection efficiency, and spectral quality.
arXivarXiv · · November 16, 2017
0
First results from the DEAP-3600 dark matter search with argon at SNOLAB
DEAP-3600 CollaborationP.-A. AmaudruzM. BaldwinM. BatygovB. BeltranC. E. BinaD. BishopJ. BonattG. BoormanM. G. BoulayB. BroermanT. Bromwich  +93
DEAP-3600, a single-phase liquid argon detector 2 km underground at SNOLAB, reports its first dark-matter search results. Using 4.44 live days (9.87 tonne-days fiducial exposure), it achieved electronic-recoil rejection via pulse-shape discrimination with leakage $<1.2\times 10^{-7}$ (90% C.L.) in 16–33 keV$_{ee}$. No candidate events were observed, yielding the leading WIMP-nucleon spin-independent cross-section limit on argon: $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/$c^2$ WIMP mass (90% C.L.).
arXivarXiv · · July 25, 2017
0
175
A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials
T. BrunnerA.R. MuellerK. O&#39;SullivanM.C. SimonM. KossickS. EttenauerA.T. GallantE. ManéD. BishopM. GoodG. GrattaJ. Dilling
The paper presents a Bradbury Nielsen ion gate fabricated from two photo-etched stainless steel grids, which replaces the challenging wire-winding of traditional designs. This construction handles beam areas up to 900 mm² and wire spacings as fine as 250 µm, with simple grid swaps to change spacing. The gate was tested at TRIUMF’s TITAN facility, validating its operation for time-of-flight separation of ions with different mass-to-charge ratios using both symmetric and asymmetric potentials.
arXivarXiv · · July 20, 2011
0
65
The T2K Experiment
T2K CollaborationK. Abe…D. Bishop
The T2K experiment is a long-baseline neutrino oscillation experiment that uses a muon neutrino beam from J-PARC directed at the Super-Kamiokande far detector 295 km away. Its main contribution is measuring the mixing angle θ₁₃ through νₑ appearance, while also performing precision measurements of Δm²₂₃ and sin²2θ₂₃ via νₘ disappearance, and conducting cross-section studies and sterile neutrino searches. This paper provides a comprehensive review of the instrumentation of each subsystem.
arXivarXiv · · June 7, 2011
0
1k+
Status Update on the ISAC Control System
R. KeitelD.BishopD.DaleH.HuiS.KadantsevM.LerossR.NussbaumerJ.RichardsE.TikhomolovG.Waters
The paper reports the completion of the EPICS-based control system for the ISAC radioactive beam facility. The target ion source, mass separator, and low-energy beamlines began beam production, while controls for the accelerator system (RFQ and drift-tube linac) and high-energy beamlines were commissioned, with the number of controlled devices having more than doubled. An overview of the relational database, software engineering, and quality control methods is provided.
arXivarXiv · · November 9, 2001
0
Frequent collaborators
B. Shaw (5)
P.E. Garrett (4)
A.B. Garnsworthy (4)
G. Hackman (4)
J.K. Smith (4)
C.E. Svensson (4)
C. Lim (4)
T. Lindner (4)
K. Olchanski (4)
Y. Linn (4)
R. Kruecken (3)
B. Olaizola (3)