MCP
FC

F. Cei

30 papers in the library

Papers

30
The Use of O2 in Gas Mixtures for Drift Chambers
A. M. BaldiniL. BiancoH. BenmansourG. CavotoF. CeiM. ChiappiniA. CorvagliaM. FrancesconiE. GabbrielliL. GalliG. GallucciF. Grancagnolo  +11
Contrary to the common belief that oxygen strongly reduces electron survival in drift chambers, the MEG II experiment has operated a He:Isobutane (90:10) drift chamber for years with 0.5% oxygen and 1.5% isopropanol. Electron attachment in this mixture is negligible enough for proper operation and matches Garfield++ simulations after accounting for three-body attachment. Oxygen and isopropanol are essential for the chamber's function.
arXivarXiv · · November 10, 2025
0
New limit on the μ+->e+γdecay with the MEG II experiment
K. AfanacievA. M. BaldiniS. BanH. BenmansourG. BocaP.W. CattaneoG. CavotoF. CeiM. ChiappiniA. CorvagliaG. Dal MasoA. De Bari  +56
The MEG II experiment at the Paul Scherrer Institut reports a new search for the lepton-flavor-violating decay $\mu^+ \to e^+ \gamma$ using 2021–2022 data. With a sensitivity of $2.2 \times 10^{-13}$, a factor 2.4 better than the full MEG dataset in about one quarter of the data-taking time, the result is consistent with background and sets an upper limit on the branching ratio of $\mathcal{B}(\mu^+ \to e^+ \gamma) < 1.5 \times 10^{-13}$ at 90% confidence level, the most stringent bound to date.
arXivarXiv · · April 22, 2025
0
138
A compact frozen-spin trap for the search for the electric dipole moment of the muon
A. AdelmannA.R. BainbridgeI. BaileyA. BaldiniS. BasnetN. BergerC. CalzolaioL. CaminadaG. CavotoF. CeiR. ChakrabortyC. Chavez Barajas  +48
The paper presents a conceptual design for a compact frozen-spin trap to search for the muon electric dipole moment (EDM). The technique exploits the high effective electric field $E \approx 165$ MV/m experienced in the muon rest frame when 23 MeV/c muons pass through a 2.5 T solenoidal field. In Phase I at Paul Scherrer Institute, the expected sensitivity is $4 \times 10^{-21}$ ecm after 200 days. Phase II aims for $6 \times 10^{-23}$ ecm using a dedicated instrument with 125 MeV/c muons.
arXivarXiv · · January 31, 2025
0
22
Search for the X17 particle in 7Li(p,e+e−)8Be^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^{-}) ^{8}\mathrm{Be} processes with the MEG II detector
MEG II collaborationK. AfanacievA. M. BaldiniS. BanH. BenmansourG. BocaP. W. CattaneoG. CavotoF. CeiM. ChiappiniA. CorvagliaG. Dal Maso  +55
The MEG II detector, designed for muon decays, was used to search for the hypothetical X17 particle in $^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^-) ^{8}\mathrm{Be}$ reactions. After four weeks of data-taking with a 1080 keV proton beam, exciting Q-value resonances at 17.6 and 18.1 MeV, no significant signal was found. Upper limits at 90% C.L. on the branching ratios relative to $\gamma$ emission were set at $R_{17.6} < 1.8 \times 10^{-6}$ and $R_{18.1} < 1.2 \times 10^{-5}$.
arXivarXiv · · November 12, 2024
0
27
A search for μ+→e+γμ^+\to e^+γ with the first dataset of the MEG II experiment
MEG II collaborationK. AfanacievA. M. BaldiniS. BanV. BaranovH. BenmansourM. BiasottiG. BocaP. W. CattaneoG. CavotoF. CeiM. Chiappini  +70
The MEG II experiment at the Paul Scherrer Institut reports a search for the charged-lepton-flavor-violating decay $\mu^+\to e^+\gamma$ using its first physics run in 2021. No signal excess is observed, setting an upper limit on the branching ratio B($\mu^+\to e^+\gamma$) < $7.5 \times 10^{-13}$ (90% C.L.). Combining this with the previous MEG limit yields B($\mu^+\to e^+\gamma$) < $3.1 \times 10^{-13}$ (90% C.L.), the most stringent limit to date.
arXivarXiv · · October 19, 2023
0
Improved muon decay simulation with McMule and Geant4
A. GurgoneA. PapaP. SchwendimannA. SignerY. UlrichA. M. BaldiniF. CeiM. ChiappiniM. FrancesconiL. GalliM. GrassiD. Nicolò  +1
This work presents an improved simulation of muon decay for the MEG II experiment, combining the McMule Monte Carlo framework with the Geant4 toolkit. The new simulation enables more accurate characterization of detector response and sensitivity estimation for searches of invisible particles in rare muon decays, extending the experiment's physics programme.
arXivarXiv · · November 3, 2022
0
The large scale polarization explorer (LSPE) for CMB measurements: performance forecast
LSPE collaborationG. Addamo…F. Cei
LSPE, combining the ground-based Strip telescope and the balloon-borne SWIPE instrument, will observe CMB polarization from the Northern Hemisphere. Its design targets a sensitivity to the tensor-to-scalar ratio of $\sigma_r<0.01$, enabling competitive constraints on inflationary B-modes. The forecast accounts for scanning strategy, component separation, foreground residuals, and systematic effects, demonstrating that the two-instrument configuration can reach the target sensitivity despite partial sky coverage.
arXivarXiv · · August 25, 2020
0
88
The Drift Chamber of the MEG II experiment
G.F. TassielliA. M. BaldiniG. CavotoF. CeiM. ChiappiniG. ChiarelloA. CorvagliaM. FrancesconiL. GalliF. GrancagnoloM. GrassiM. Hildebrandt  +10
The MEG II experiment searches for the lepton-flavor-violating decay $\mu^+ \to e^+ \gamma$, aiming to improve the current best upper limit of $4.2 \times 10^{-13}$. Its central new detector is a ultra-light, modular cylindrical drift chamber (CDCH) with 9 layers of 192 square drift cells in a full stereo configuration, using approximately 12,000 wires at a density of 12 wires/cm$^2$. To meet stringent wire-position and tension requirements (better than 0.5 g), the chamber is built by alternately stacking multiwire frames (16 or 32 wires soldered on wire-PCBs) and PEEK spacers, enabling automated assembly while keeping material at only $1.5 \times 10^{-3} X_0$ for high-efficiency positron tracking above 45 MeV/$c$.
arXivarXiv · · June 3, 2020
0
The new drift chamber of the MEG II experiment
M. ChiappiniA. M. BaldiniG. CavotoF. CeiG. ChiarelloM. FrancesconiL. GalliF. GrancagnoloM. GrassiM. HildebrandtD. NicolòM. Panareo  +6
The MEG II cylindrical drift chamber (CDCH) provides a low-mass ($1.5\times10^{-3}\,X_0$) high-granularity tracker for the $\mu^+\to e^+\gamma$ search at $6\times10^{-14}$ sensitivity. It comprises 9 layers of 192 stereo drift cells defined by ~12,000 wires, achieving 110 $\mu$m hit resolution and 130 keV/c momentum resolution while minimizing multiple Coulomb scattering.
arXivarXiv · · May 5, 2020
0
Commissioning of the MEG II tracker system
M. ChiappiniA. M. BaldiniG. CavotoF. CeiG. ChiarelloA. CorvagliaM. FrancesconiL. GalliF. GrancagnoloM. GrassiM. HildebrandtM. Meucci  +10
The MEG II tracker aims to improve the sensitivity of the search for the $\mu^+ \rightarrow e^+ \gamma$ decay by an order of magnitude over the earlier MEG experiment. Its central component is the Cylindrical Drift CHamber (CDCH), a low-mass, high-granularity detector with 9 layers of 192 drift cells in a stereo configuration, achieving a single-hit resolution below 120 $\mu$m and angular and momentum resolutions of 6 mrad and 90 keV/c. The paper describes the CDCH commissioning at PSI, including endcap preparation, HV tests, and integration into the MEG II apparatus for the 2018–2019 engineering runs.
arXivarXiv · · May 5, 2020
0
Progress report on the Large Scale Polarization Explorer
L. LamagnaG. Addamo…F. Cei
The Large Scale Polarization Explorer (LSPE) is a cosmology program aiming to constrain the tensor-to-scalar ratio $r$ down to $10^{-2}$ by measuring B-modes in the cosmic microwave background polarization. It combines two instruments: LSPE/STRIP, a ground-based coherent receiver array for characterizing low-frequency galactic polarized signals, and LSPE/SWIPE, a balloon-borne bolometric polarimeter with 330 multi-moded detectors targeting CMB polarization at 150 GHz and galactic dust emission above 200 GHz. This report covers the pre-commissioning phase of STRIP and the characterization of SWIPE's key subsystems before integration.
arXivarXiv · · May 3, 2020
0
30
Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment
A. M. BaldiniF. BergM. BiasottiG. BocaP. W. CattaneoG. CavotoF. CeiM. ChiappiniG. ChiarelloC. ChiriA. CorvagliaA. de Bari  +59
The MEG experiment reports the first direct search for the lepton flavour violating decay $\mu^+ \to e^+ X$, $X \to \gamma\gamma$, mediated by a new light particle $X$. Using $7.5\times 10^{14}$ stopped muons collected during 2009--2013, no significant excess is found for $X$ masses 20--45 MeV/c$^2$ and lifetimes below 40 ps. The most stringent upper limits on the branching ratio are set in the 20--40 MeV/c$^2$ mass range, down to $\mathcal{O}(10^{-11})$ at 90% confidence level.
arXivarXiv · · May 1, 2020
0
37
Mu2e calorimeter readout system
N.AtanovV.BaranovL.BaldiniJ.BudagovD.CaiuloF.CeiF.CervelliF.ColaoM.CordelliG.CorradiYu.I.DavydovF.D&#39;Errico  +34
The Mu2e calorimeter readout system, designed for the hostile environment of 20 krads ionization, $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$ neutron flux, 1 T magnetic field, and $10^{-4}\ \text{Torr}$ vacuum, uses two types of modules: 2696 front-end modules (shaping amplifier and high-voltage regulator, one per SiPM) and 136 waveform digitizer boards (200 MHz, 12-bit ADC, one per 20 SiPMs) to read out two disks of undoped CsI crystals with SiPM arrays. The paper describes the system and its qualification tests.
arXivarXiv · · July 9, 2019
0
5
Gas Distribution and Monitoring for the Drift Chamber of the MEG-II Experiment
A. M. BaldiniE. BaracchiniG. CavotoF. CeiM. ChiappiniG. ChiarelloC. ChiriM. FrancesconiL. GalliF. GrancagnoloM. GrassiM. Hildebrandt  +13
The MEG-II experiment's drift chamber, used to reconstruct positron tracks in the search for $\mu^+ \to e^+ \gamma$, requires a stable helium-isobutane gas mixture. This paper describes the strategies for ensuring controlled composition, purity, and continuous monitoring of the gas to meet the detector's performance needs. A small chamber was built and commissioned for online gas quality monitoring.
arXivarXiv · · April 23, 2018
0
The design of the MEG II experiment
A.M. BaldiniE. BaracchiniC. BemporadF. BergM. BiasottiG. BocaP.W. CattaneoG. CavotoF. CeiM. ChiappiniG. ChiarelloC. Chiri  +64
The MEG II experiment is a major upgrade of the MEG experiment to search for the lepton-flavor-violating decay $\mu^+ \to e^+ \gamma$ with a target sensitivity of $6 \times 10^{-14}$ in branching ratio, an order of magnitude improvement over MEG's $10^{-13}$ level. This paper presents the motivation for the upgrade and a detailed overview of the experiment's design and expected detector performance.
arXivarXiv · · January 15, 2018
0
Single-hit resolution measurement with MEG II drift chamber prototypes
A. M. BaldiniE. BaracchiniG. CavotoM. CascellaF. CeiM. ChiappiniG. ChiarelloC. ChiriS. DussoniL. GalliF. GrancagnoloM. Grassi  +12
The MEG II drift chamber uses helium-based gas to minimize material, but primary ionization fluctuations limit spatial resolution. Three prototypes operated with helium/isobutane were tested with cosmic rays, electron beams, and radioactive sources. Direct measurements using an external tracker yielded a single-hit resolution of 110 μm, consistent with indirect measurements from the other prototypes. This establishes the achievable resolution for the MEG II tracker.
arXivarXiv · · May 25, 2016
0
Muon polarization in the MEG experiment: predictions and measurements
A. M. BaldiniY. BaoE. BaracchiniC. BemporadF. BergM. BiasottiG. BocaP.W. CattaneoG. CavotoF. CeiG. ChiarelloC. Chiri  +58
The MEG experiment uses a high-intensity muon beam to search for $\mu^+ \to e^+\gamma$. By measuring the energy-dependent asymmetry of Michel decay positrons, the residual muon polarization at the stopping target is determined to be $P_\mu = -0.85 \pm 0.03\,(\text{stat})\,^{+0.04}_{-0.05}\,(\text{syst})$, consistent with the Standard Model prediction of $P_\mu=-1$ after accounting for depolarization during production, propagation, and moderation. This polarization measurement is essential for modeling the background from the muon radiative decay $\mu^+ \to e^+ \bar{\nu}_\mu \nu_e \gamma$.
arXivarXiv · · October 15, 2015
0
Measurement of the radiative decay of polarized muons in the MEG experiment
MEG CollaborationA. M. BaldiniY. BaoE. BaracchiniC. BemporadF. BergM. BiasottiG. BocaP. W. CattaneoG. CavotoF. CeiG. Chiarello  +59
Using an almost fully polarized muon source, the MEG experiment measured the radiative muon decay μ⁺ → e⁺νν̄γ for the first time under such conditions. From 1.8×10¹⁴ collected decays, about 13000 events were identified, yielding a branching ratio B(μ⁺ → e⁺νν̄γ) = (6.03±0.14±0.53)×10⁻⁸ for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model. This measurement serves as a calibration tool, normalization channel, and quality check for the search of μ⁺ → e⁺γ.
arXivarXiv · · December 11, 2013
0
227
Dual-readout Calorimetry
N. AkchurinF. BedeschiA. CardiniM. CascellaF. CeiD. De PedisS. FracchiaS. FranchinoM. FraternaliG. GaudioP. GenovaJ. Hauptman  +11
Dual-readout calorimetry, studied by the RD52 Project at CERN, provides unprecedented event-by-event information for hadronic energy measurement, including resolution, linearity, calibration robustness, and particle identification. The project finds that dual-readout calorimeters can achieve hadronic energy resolutions of $\sigma/E \approx 1-2\%$, enabling comparable measurement precision for electrons, photons, muons, and jets for the first time.
arXivarXiv · · July 21, 2013
0
The MEG detector for μ+→e+γμ+\to e+γ decay search
J. AdamX. BaiA. M. BaldiniE. BaracchiniC. BemporadG. BocaP. W. CattaneoG. CavotoF. CeiC. CerriM. CorboN. Curalli  +64
The MEG detector searches for the lepton-flavor-violating decay $\mu^+ \to e^+ \gamma$ using an intense continuous $\mu^+$ beam at PSI. Its central design combines a positron spectrometer (thin target, superconducting magnet, drift chambers, timing counter) with a liquid xenon photon detector to measure energy, position, and time of both decay products. The trigger, read-out electronics, data acquisition, calibration techniques, and full simulation complete the apparatus. This paper provides a comprehensive description of the entire detector system.
arXivarXiv · · March 10, 2013
0
New constraint on the existence of the mu+-> e+ gamma decay
MEG CollaborationJ. AdamX. BaiA. M. BaldiniE. BaracchiniC. BemporadG. BocaP. W. CattaneoG. CavotoF. CeiC. CerriA. de Bari  +62
Using data from the MEG experiment at the Paul Scherrer Institut, totaling $3.6 \times 10^{14}$ stopped muons on target, a search for the lepton flavour violating decay $\mu^+ \to e^+ \gamma$ found no excess over background expectations. This yields a new upper limit on the branching ratio of $5.7 \times 10^{-13}$ at 90% confidence level, which is four times more stringent than the previous world best limit from MEG.
arXivarXiv · · March 4, 2013
0
MEG Upgrade Proposal
A. M. BaldiniF. CeiC. CerriS. DussoniL. GalliM. GrassiD. NicolòF. RaffaelliF. SergiampietriG. SignorelliF. TenchiniD. Bagliani  +56
This paper proposes an upgrade of the MEG experiment to search for the charged lepton flavour violating decay $\mu \to e \gamma$, aiming to improve sensitivity by an order of magnitude to $6 \times 10^{-14}$. The upgrade increases detector rate capability for higher beam intensity and improves energy, angular, and timing resolutions. Plans include a new low-mass, high-granularity positron tracker, a segmented timing counter, enhanced granularity of the liquid xenon photon detector, and a unified readout board.
arXivarXiv · · January 30, 2013
0
239
New limit on the lepton-flavour violating decay mu -> e gamma
MEG collaborationJ. AdamX. BaiA. M. BaldiniE. BaracchiniC. BemporadG. BocaP. W. CattaneoG. CavotoF. CeiC. CerriA. de Bari  +55
New data from the MEG detector at the Paul Scherrer Institut, collected in 2009–2010 and corresponding to $1.8 \times 10^{14}$ muon decays, yield a 90% confidence-level upper limit of $2.4 \times 10^{-12}$ on the branching ratio of the lepton-flavour violating decay $\mu \to e \gamma$. This result is the most stringent limit on this decay to date.
arXivarXiv · · July 27, 2011
0
A limit for the mu -> e gamma decay from the MEG experiment
MEG collaborationJ. AdamX. BaiA. BaldiniE. BaracchiniA. BarchiesiC. BemporadG. BocaP. W. CattaneoG. CavotoG. CecchetF. Cei  +58
The MEG experiment at PSI searched for the lepton flavor violating decay $\mu \to e \gamma$ using data from its first three months of operation. A superconducting positron spectrometer and a 900-liter liquid xenon photon detector examined positrons and photons from about $10^{14}$ stopped muon decays. The result sets an upper limit on the branching ratio of $\text{BR}(\mu \to e \gamma) < 2.8 \times 10^{-11}$ at 90% confidence level.
arXivarXiv · · August 18, 2009
0
Physics at a Fermilab Proton Driver
M.G.AlbrowS.AntuschK.S.BabuT.BarnesA.O.BazarkoR.H.BernsteinT.J.BowlesS.J.BriceA.CeccucciF.CeiH.W.KCheungD.C.Christian  +36
The report presents the physics case for constructing a 2 MW, 8 GeV superconducting linac proton driver at Fermilab, arguing that such a facility would enable a broad program of neutrino, muon, and hadron physics experiments beyond the reach of current facilities.
arXivarXiv · · September 16, 2005
0
19
Absorption of Scintillation Light in a 100 ℓ\ell Liquid Xenonγγ Ray Detector and Expected Detector Performance
A.BaldiniC.BemporadF.CeiT.DokeM.GrassiA.A.GrebenukD.N.GrigorievT.HaruyamaK.KasamiJ.KikuchiA.MakiT.Mashimo  +19
The authors report a method to separate absorption from elastic scattering of scintillation light in a 100 L liquid xenon detector, developed for the MEG experiment's search for $\mu^+\to\mathrm{e}^+\gamma$ decay. By measuring cosmic rays and $\alpha$ sources, they independently evaluate the absorption length. After purification, an absorption length over 100 cm is achieved, and Monte Carlo simulation estimates its impact on energy resolution.
arXivarXiv · · July 7, 2004
0
Liquid Xe scintillation calorimetry and Xe optical properties
A. BaldiniC. BemporadF. CeiT. DokeM. GrassiT. HaruyamaS. MiharaT. MoriD. NicolòH. NishiguchiW. OotaniK. Ozone  +7
This work derives the optical properties of liquid xenon (LXe) in the vacuum ultraviolet (VUV) region, which determine the performance of a scintillation calorimeter, by examining available data from visible-to-UV light measured over a wide range of Xe densities. The derived properties are compared with direct VUV measurements from LXe excitation by ionizing particles. A relation connecting the Rayleigh scattering length to the refractive index in LXe is obtained.
arXivarXiv · · January 15, 2004
0
Search for neutrino oscillations on a long base-line at the CHOOZ nuclear power station
M. ApollonioA. BaldiniC. BemporadE. CaffauF. CeiY. DeclaisH. de KerretB. DieterleA. EtenkoL. ForestiJ. GeorgeG. Giannini  +28
The CHOOZ experiment searched for electron antineutrino ($\bar{\nu}_e$) disappearance over a long baseline (≈1 km) from a nuclear reactor. No oscillation signal was observed, establishing a new upper limit on the mixing angle $\theta_{13}$ at the relevant mass-squared difference. The final analysis includes a detailed account of the detector, calibration, and systematic-error treatment, refining the confidence limits for the oscillation parameters.
arXivarXiv · · January 13, 2003
0
Limits on Neutrino Oscillations from the CHOOZ Experiment
M. ApollonioA. BaldiniC. BemporadE. CaffauF. CeiY. DeclaisH. de KerretB. DieterleA. EtenkoL. ForestiJ. GeorgeG. Giannini  +28
The CHOOZ experiment found no evidence for $\bar{\nu}_e$ disappearance through neutrino oscillations. At 90% confidence, the excluded parameter region includes $\Delta m^2 > 7 \times 10^{-4}$\,eV$^2$ for maximal mixing and $\sin^2(2\theta) = 0.10$ for large $\Delta m^2$. A secondary analysis based solely on spectral comparison between two reactors yields results independent of absolute flux normalization, cross section, target proton count, and detector efficiency.
arXivarXiv · · July 19, 1999
0
Determination of neutrino incoming direction in the CHOOZ experiment and Supernova explosion location by scintillator detectors
M. ApollonioA. BaldiniC. BemporadE. CaffauF. CeiY. DeclaisH. de KerretB. DieterleA. EtenkoL. ForestiJ. GeorgeG. Giannini  +28
Using data from the CHOOZ experiment, which measured reactor antineutrino flux at ~1 km to search for oscillations, the authors show that analysis of electron antineutrino events in the liquid scintillation detector can locate the source within a cone of 18° half-aperture at 68% C.L. This result suggests that similar scintillator detectors could determine the direction of a supernova explosion.
arXivarXiv · · June 7, 1999
0
Frequent collaborators
M. Grassi (25)
L. Galli (21)
G. Signorelli (21)
A. Papa (20)
A. M. Baldini (19)
G. Cavoto (19)
F. Renga (19)
M. Panareo (18)
C. Voena (18)
M. Hildebrandt (16)
D. Nicolò (16)
F. Grancagnolo (14)