MCP
SK

S. Kopp

34 papers in the library

Papers

30
The NuMI Neutrino Beam
P. AdamsonK. Anderson…S. Kopp
The paper describes the hardware, operations, and design considerations of the NuMI neutrino beam at Fermilab. It details key components, beam monitoring systems, procedures for tuning and alignment, and reports on the long-term performance of the beam. The work constitutes a comprehensive technical reference on the NuMI beamline.
arXivarXiv · · July 23, 2015
0
591
Measurements of atmospheric neutrinos and antineutrinos in the MINOS Far Detector
MINOS CollaborationP. Adamson…S. Kopp
Using 2553 live-days of MINOS Far Detector data, the atmospheric neutrino and antineutrino charged-current interactions are separated via muon track curvature in a magnetic field. A maximum likelihood fit to the $L/E$ distributions of both samples yields 90% confidence limits of $|\Delta m^{2}| = (1.9 \pm 0.4) \times 10^{-3}~\text{eV}^{2}$ and $\sin^{2}2\theta > 0.86$. Extending the fit to allow different oscillation parameters for neutrinos and antineutrinos gives $|\Delta m^{2}| - |\Delta \bar{m}^{2}| = 0.6^{+2.4}_{-0.8} \times 10^{-3}~\text{eV}^{2}$, consistent with equal splittings.
arXivarXiv · · August 14, 2012
0
91
Measurement and manipulation of beta functions in the Fermilab Booster
M. McAteerS. KoppE. Prebys
The Fermilab Booster aims to nearly double its proton throughput, and a new system of 48 ramped corrector magnets is expected to help. This paper reports preliminary beta function measurements made using these correctors, marking the first step toward using them to reduce beta function irregularities and introduce localized beta bumps for lower beam loss and controlled collimation.
arXivarXiv · · March 7, 2012
0
An improved measurement of muon antineutrino disappearance in MINOS
P. AdamsonD. S. Ayres…S. Kopp
Using the MINOS detectors and a muon antineutrino-enhanced beam from the Fermilab Main Injector over 735 km, the improved measurement yields the most precise antineutrino atmospheric mass-squared splitting $\Delta\bar{m}^2 = [2.62^{+0.31}_{-0.28}(\text{stat.})\pm0.09(\text{syst.})]\times10^{-3}$ eV$^2$ and constrains the mixing angle $\sin^2(2\bar{\theta}) > 0.75$ (90% CL). These values agree with the neutrino parameters, removing earlier tension.
arXivarXiv · · February 13, 2012
0
Search for Lorentz invariance and CPT violation with muon antineutrinos in the MINOS Near Detector
P. AdamsonD. S. Ayres…S. Kopp
This paper reports a search for sidereal variations in the rate of muon antineutrino interactions using the MINOS Near Detector and the NuMI beam. No statistically significant modulation was found. The null result sets upper limits on Lorentz- and CPT-violating coefficients in the Standard-Model Extension; combining with earlier MINOS neutrino data further tightens those constraints.
arXivarXiv · · January 12, 2012
0
The 2010 Interim Report of the Long-Baseline Neutrino Experiment Collaboration Physics Working Groups
LBNE CollaborationT. Akiri…S. Kopp
This report summarizes the 2010 study by the Long-Baseline Neutrino Experiment (LBNE) collaboration evaluating the physics potential of various beam, near-detector, and far-detector configurations. Nine scientific topics motivating a very large far detector were identified, with performance estimates given for reference far-detector designs. Optimized beam parameters and near-detector physics capability were also assessed. This document was presented to the collaboration in fall 2010 and updated in early 2011.
arXivarXiv · · October 27, 2011
0
101
Search for the disappearance of muon antineutrinos in the NuMI neutrino beam
MINOS CollaborationP. Adamson…S. Kopp
Using the two MINOS detectors, the 7% muon antineutrino component of the NuMI beam is studied. In the Far Detector, 130 charged-current events are observed, consistent with the no-oscillation prediction of 128 events. A two-flavor oscillation fit, assuming no oscillations at the Near Detector baseline, constrains $|\Delta\bar{m}^2| < 3.37 \times 10^{-3}\,\text{eV}^2$ at 90% confidence level for $\sin^2 2\bar{\theta} = 1.0$, with the best-fit point at $|\Delta\bar{m}^2| = 2.32 \times 10^{-3}\,\text{eV}^2$ and $\sin^2 2\bar{\theta} = 1.0$.
arXivarXiv · · August 6, 2011
0
56
Improved search for muon-neutrino to electron-neutrino oscillations in MINOS
MINOS CollaborationP. Adamson…S. Kopp
The MINOS long-baseline neutrino experiment reports an improved search for $\nu_e$ appearance in a $\nu_\mu$ beam. Using an improved analysis and increased exposure, they constrain the mixing parameter to $2\sin^2(\theta_{23})\sin^2(2\theta_{13})<0.12$ (0.20) at 90% confidence for $\delta=0$ and the normal (inverted) mass hierarchy, with best fits of $0.041^{+0.047}_{-0.031}$ ($0.079^{+0.071}_{-0.053}$). The $\theta_{13}=0$ hypothesis is disfavored at 89% confidence level.
arXivarXiv · · July 29, 2011
0
1k+
Active to sterile neutrino mixing limits from neutral-current interactions in MINOS
MINOS CollaborationP. Adamson…S. Kopp
Using neutral-current interactions in the MINOS long-baseline experiment, a search for active to sterile neutrino oscillations sets a limit on the fraction $f_s$ of disappearing muon neutrinos that may transition to a sterile neutrino $\nu_s$. With $7.07\times10^{20}$ protons on target, 802 neutral-current event candidates are observed in the Far Detector, compared to $754\pm28\rm{(stat.)}\pm37\rm{(syst.)}$ expected for three active flavors. At 90% confidence level, $f_s$ is less than 22%.
arXivarXiv · · April 20, 2011
0
239
First direct observation of muon antineutrino disappearance
MINOS collaborationP. Adamson…S. Kopp
The MINOS experiment reports the first direct observation of muon antineutrino disappearance, using an accelerator beam optimized for muon antineutrino production. With an exposure of $1.71\times10^{20}$ protons on target, only 97 charged current events were observed in the Far Detector compared to the 156 expected under no oscillation, excluding the no-oscillation hypothesis at $6.3\sigma$. The best fit yields oscillation parameters $\Delta\bar{m}^2 = (3.36^{+0.46}_{-0.40}\pm0.06)\times10^{-3}\,\text{eV}^2$ and $\sin^2(2\bar{\theta}) = 0.86^{+0.11}_{-0.12}\pm0.01$, consistent with muon neutrino oscillation.
arXivarXiv · · April 3, 2011
0
150
Measurement of the neutrino mass splitting and flavor mixing by MINOS
MINOS CollaborationP. Adamson…S. Kopp
Using muon-neutrino disappearance data from the Fermilab NuMI beam observed by the MINOS detectors, the collaboration reports improved measurements of the atmospheric neutrino mass splitting and mixing angle. Based on a $7.25 \times 10^{20}$ protons-on-target exposure, an oscillation analysis yields $|\Delta m^2| = (2.32^{+0.12}_{-0.08})\times10^{-3}$ eV$^2$ and $\sin^2\!(2\theta) > 0.90$ (90% C.L.). Neutrino decay and quantum decoherence are ruled out at 7 and 9 standard deviations, respectively.
arXivarXiv · · March 2, 2011
0
526
A Search for Lorentz Invariance and CPT Violation with the MINOS Far Detector
MINOS CollaborationP. Adamson…S. Kopp
The MINOS collaboration searched for a sidereal modulation in the far detector neutrino rate, which would indicate Lorentz and CPT violation as described by the Standard-Model Extension (SME). No evidence for such a signal was found. The resulting upper limits on the SME coefficients are $20-510$ times more stringent than the previous best limits from the MINOS near detector.
arXivarXiv · · July 16, 2010
0
Expression of Interest for Neutrinos Scattering on Glass: NuSOnG
NuSOnG CollaborationT. AdamsL. BugeJ.M. ConradP.H. FisherJ.A. FormaggioA. de GouvêaW.A. Loinaz1G. KaragiorgiT.R. KobilarcikS. KoppG. Kyle  +16
The NuSOnG proposal describes a 3500-ton SiO₂ neutrino detector for the Tevatron Fixed Target Program, expected to achieve over 100 times the event statistics of the previous NuTeV experiment. With a 5-year run, it would enable high-precision measurements of the purely weak processes $\nu_{\mu} e^- \to \nu_{\mu} + e^-$ and inverse muon decay $\nu_{\mu} e^- \to \nu_e + \mu^-$, the latter being free of strong interaction effects and thus improving flux normalization for all other processes. The high fluxes also allow searches for lepton flavor violation and neutral heavy leptons.
arXivarXiv · · July 28, 2009
0
2
QCD Precision Measurements and Structure Function Extraction at a High Statistics, High Energy Neutrino Scattering Experiment: NuSOnG
T. AdamsP. BatraL. BugelL. CamilleriJ. M. ConradA. de GouvêaP. H. FisherJ. A. FormaggioJ. JenkinsG. KaragiorgiT. R. KobilarcikS. Kopp  +24
The paper proposes NuSOnG, a high-statistics neutrino scattering experiment using a Tevatron-based neutrino beam, to achieve over two orders of magnitude more Deep Inelastic Scattering events than previous samples. Its central contribution is an innovative method for fitting structure functions via a parameterized energy shift, which reduces systematic uncertainties. This enables precision QCD measurements, including extraction of Parton Distribution Functions, and discerning tests of Standard Model parameters sensitive to beyond-the-Standard-Model physics.
arXivarXiv · · June 19, 2009
0
12
First Measurement of νμν_μ and νeν_e Events in an Off-Axis Horn-Focused Neutrino Beam
P. AdamsonA. A. Aguilar-Arevalo…S. Kopp
The MiniBooNE detector, placed 745 m from the NuMI target at an off-axis angle of 110 mrad (6.3°), observed charged-current quasi-elastic ν_μ and ν_e interactions from the NuMI beamline. The measured event rates agree with expectations, directly verifying the predicted pion and kaon contributions to the neutrino flux and confirming the modeling of the off-axis beam.
arXivarXiv · · September 15, 2008
0
Terascale Physics Opportunities at a High Statistics, High Energy Neutrino Scattering Experiment: NuSOnG
T. AdamsP. BatraL. BugelL. CamilleriJ.M. ConradA. de GouveaP.H. FisherJ.A. FormaggioJ. JenkinsG. KaragiorgiT.R. KobilarcikS. Kopp  +24
This paper proposes NuSOnG, a Tevatron-based neutrino scattering experiment that would collect over an order of magnitude more events for weak processes like $\nu_{\mu}+e^- \to \nu_{\mu}+ e^-$ and $\nu_{\mu}+ e^- \to \nu_e + \mu^-$, and over two orders more Deep Inelastic Scattering events than past samples. Its high statistics and high energy beam enable unique sensitivity to TeV-scale new physics, such as $Z'$ bosons or extra dimensions, that modify neutrino cross sections through corrections to gauge couplings or propagators, reaching mass scales beyond 5 TeV.
arXivarXiv · · March 4, 2008
0
45
Considerations for an Ac Dipole for the LHC
M. BaiR. CalagaW. FischerP. OddoH. SchmicklerJ. SerranoA. JanssonM. SyphersS. KoppR. Miyamoto
An AC Dipole will be used at the LHC for rapid ring optics measurements, following successful implementations at BNL, FNAL, and CERN. The paper describes the LHC AC dipole parameters by scaling from the performance of the FNAL and BNL devices.
arXivarXiv · · September 18, 2007
0
7
Beam-Based Alignment of the NuMI Target Station Components at FNAL
R. ZwaskaM. BishaiS. ChildressG. DrakeC. EscobarP. GouffonD.A. HarrisJ. HylenD. IndurthyG. KoizumiS. KoppP. Lucas  +6
The relative alignment of the NuMI target, focusing horns, and primary proton beam at FNAL affects the delivered neutrino energy spectrum. This paper reports a beam-based check of the alignment of these components by using the proton beam itself, providing a direct method to verify the positioning of the target station components without relying on external surveys.
arXivarXiv · · September 13, 2006
0
Secondary Beam Monitors for the NuMI Facility at FNAL
S. KoppM. BishaiM. DierckxsensM. DiwanA.R. ErwinD.A. HarrisD. IndurthyR. KeislerM. KostinM. LangJ. MacDonaldA. Marchionni  +11
Four arrays of ionization chambers were built for the NuMI neutrino beam facility at Fermilab to monitor the position and intensity of the hadron and muon beams downstream of the decay volume. The paper describes the chambers' construction, calibration, and commissioning in the beam, providing a practical characterization of these secondary beam monitors used for neutrino production.
arXivarXiv · · July 26, 2006
0
48
Beam Test of a Segmented Foil SEM Grid
S.KoppD. IndurthyZ. PavlovichM. ProgaR. ZwaskaS. ChildressR. FordC. KendzioraT. KobilarcikC. MooreG. Tassotto
A prototype secondary-electron emission monitor (SEM) using a segmented grid of 5 µm Ti foils was tested in the 8 GeV proton line for MiniBooNE. Full signal collection required a bias voltage, with a stronger effect at higher beam intensity. Beam centroid and width resolutions were measured at beam widths of 3, 7, and 8 mm. Extrapolating to the NuMI beam (1 mm spot size) yields expected centroid and width resolutions of 20 µm and 25 µm, respectively.
arXivarXiv · · July 29, 2005
0
Segmented Foil SEM Grids at Fermilab
S. KoppD. IndurthyZ. PavlovichM. ProgaR. ZwaskaB.BallerS.ChildressR.FordD.HarrisC.KendzioraC.MooreG.Tassotto
Fermilab tested segmented Ti-foil grids (5 µm thick) as secondary-electron emission monitors for proton beams. The new design provides beam centroid position and beam width measurements, with data reported on their precision and on beam loss caused by the foil material inserted into the beam.
arXivarXiv · · June 27, 2005
0
Ion Chamber Arrays for the Numi Beam at Fermilab
D.IndurthyZ.PavlovicR.ZwaskaR.KeislerS.MendozaS.KoppM.ProgaD.HarrisA.MarchionniJ.MorfinA.ErwinH.Ping  +7
This paper describes the construction and deployment of four arrays of ionization chambers at the NuMI beamline at Fermilab. Positioned downstream of the decay volume, these arrays monitor the neutrino beam direction and quality by measuring the remnant hadron beam and tertiary muons produced alongside neutrinos in meson decays. The goal is to characterize the intense muon neutrino beam for the NuMI experiment.
arXivarXiv · · June 26, 2005
0
5
The Cleo Rich Detector
M. ArtusoR. AyadK. BukinA. EfimovC. BoulahouacheE. DambasurenS. KoppJi LiG. MajumderN. MenaaR. MountainS. Schuh  +12
This paper presents the CLEO Rich Detector, a Ring Imaging Cherenkov (RICH) detector for charged particle identification. It uses LiF crystals, including a novel sawtooth-shaped exit surface, to produce Cherenkov radiation. Photons in the 135–165 nm range are detected by multi-wire chambers with methane and triethylamine. The detector achieves excellent pion/kaon separation.
arXivarXiv · · June 15, 2005
0
190
Synchronization of the Fermilab Booster and Main Injector for Multiple Batch Injection
R. ZwaskaS. KoppW. PellicoR. Webber
The paper presents a synchronization mechanism for the Fermilab Booster and Main Injector that enables multiple batch injection, required for future operation with six or more Booster batches. The method advances or retards the longitudinal position of the Booster beam by actively manipulating its radial position via feedback during acceleration, avoiding beamline radioactivation.
arXivarXiv · · July 1, 2004
0
Study of Neutron-Induced Ionization in Helium and Argon Chamber Gases
D.IndurthyA.R.ErwinD.HarrisS.KoppM.ProgaR.M.Zwaska
This paper reports measurements of neutron-induced ionization in helium and argon chamber gases, motivated by backgrounds in NuMI beamline ion chambers. Using PuBe neutron sources ($E_n=1-10$ MeV, $\sim10^8$ n/s), the authors derive the number of ion pairs per incident neutron in each gas. Despite limited precision from a large gamma background, the results are consistent with purely elastic neutron interactions in the chamber gas.
arXivarXiv · · May 5, 2004
0
Profile Monitor SEM's for the NuMI Beam at FNAL
D.IndurthyS.KoppZ.PavlovichM.Proga
Secondary emission monitors (SEMs) are designed for the NuMI beam line at FNAL to measure 120 GeV proton beam profiles and halo. Each SEM uses 5 µm titanium foils segmented into 1 mm or 0.5 mm pitch strips, causing a beam loss of ~5 × 10⁻⁶. The paper covers mechanical design, expected beam heating, and results from an 8 GeV test beam at FNAL.
arXivarXiv · · May 5, 2004
0
Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL
D.IndurthyR.KeislerS.KoppS.MendozaM. ProgaZ.PavlovichR.ZwaskaD.HarrisA.MarchionniJ.MorfinA.ErwinH.Ping  +6
This paper describes ionization-chamber arrays built for the NuMI beamline at FNAL, which produces a muon neutrino beam directed at the Soudan Underground Laboratory. Four arrays downstream of the decay volume measure the remnant hadron beam and tertiary muons from meson decays, providing information to steer the neutrino beam with 1 mRad angular accuracy. The paper covers chamber construction, radiation damage testing, calibration, and test beam results alongside the intended beam-quality monitoring application.
arXivarXiv · · May 5, 2004
0
0
Construction, Pattern Recognition and Performance of the CLEO III LiF-TEA RICH Detector
M. ArtusoR. AyadK. BukinA. EfimovC. BoulahouacheE. DambasurenS. KoppR. MountainG. MajumderS. SchuhT. SkwarnickiS. Stone  +10
The paper describes the design, construction, and performance of the LiF-TEA RICH detector built for CLEO III, which uses a LiF radiator and TEA photon detector to identify charged particles. The detector achieves excellent pion/kaon separation, as demonstrated by its performance. The central contribution is the successful construction and pattern recognition demonstration of this RICH detector.
arXivarXiv · · September 6, 2002
0
206
The NuMI Hadronic Hose
R. DucarJ. HylenV. GarkushaC. JensenS. KoppM. KostinA. LyukovM. MayM. MessierR. MilburneF. NovoskoltsevD. Pushka  +5
The NuMI Hadronic Hose is a continuous toroidal magnetic focusing system developed for the NuMI beamline. It steers the secondary $\pi^+$ beam more effectively inside the 675 m decay tunnel, increasing the $\nu_\mu$ flux reaching the MINOS detectors and reducing systematic differences in the neutrino energy spectra between the two detectors caused by solid angle acceptance.
arXivarXiv · · June 22, 2001
0
1
Dalitz Analysis of the Decay D0→K−π+π0D^{0}\to K^{-}π^{+}π^{0}
S. KoppCLEO Collaboration
Using high-statistics data from the CLEO II detector, this paper reports a Dalitz analysis of the decay $D^0 \to K^-\pi^+\pi^0$. The Dalitz plot is well described by a combination of seven quasi-two-body decay channels, including $\bar{K}^{*0} \pi^0$, $K^- \rho$, $K^{*-} \pi^+$, $K^*_0(1430)^-\pi^+$, $\bar{K}^*_0(1430)^0 \pi^0$, $K^- \rho^+(1700)$, and $K^*(1680)^- \pi^+$, along with a small non-resonant component. From the fitted amplitudes and phases, the integrated CP asymmetry is calculated to be $-0.031 \pm 0.086$, consistent with zero within uncertainties.
arXivarXiv · · November 20, 2000
0
Frequent collaborators
R. Zwaska (18)
D. Naples (15)
M. Bishai (14)
J. Hylen (14)
B. Viren (14)
S. Childress (13)
G. Koizumi (12)
L. Loiacono (12)
P. Lucas (12)
P. Adamson (11)
G. Barr (11)
H. R. Gallagher (11)